LTL

LOCAL TRANSPORT LOCATION

INDICATES:

The Serving Wire Center of the interLATA customer's location.

DATE:

12/9/2004

BILLING:

CABS

APPLICATIONS:

Access Service


SECTION - POSITION

EXAMPLES

S&E - FL

I1   @@A/TN 732 555-1234/LTL CHCGILAAMGO

         or

IG1  TSC AE123456/TTD DF521E
     /APZ BSTNMAGTOGO M-
     LYNNMACHP20/NC SD-B/TTC SO
     /LTL BSTNMACH221

FID RULES/CONSTRAINTS:

  1. FID is floated with BHM++ USOC or on TSC FID logical line only.
  2. C and T Action Codes are valid only on Planned Facility orders.
  3. Approved for Access Service Tariff Application only.
  4. When Element Combination is used in a series, the second location is used to indicate the Intrastate Longest Route.

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - FL

Required

Alphanumeric

11

11

Element: 1

COMMON LANGUAGE Geographical Code

Appearance

Mode

Min

Max

Series

Range

Required

Alphanumeric

4

4

No

No

Data Parameters:

A-Z

Symbols:

Space

Reference:

See BR 795-100-100 for more information on CLLI codes or go to www.commonlanguage.com/clli.

Element Rules:

Geographical Codes created after 11/8/95 must be 4 alpha characters.

Geographical Codes created prior to 11/8/95 were two to four alpha characters.  Two or 3 character codes were left justified and the unused (rightmost) positions were blank filled.  It is for the latter reason that use of the "space" text symbol is permitted and, as a result, the element mode must be shown as "AN".

The actual numeric character values of 0 through 9 are not, not have they ever been, allowed within the Geographical Code.
Required as specified in BR 795-100-100.

Element: 2

COMMON LANGUAGE Geopolitical Code

Appearance

Mode

Min

Max

Series

Range

Required

Alphabetic

2

2

No

No

Reference:

See BR 795-100-100 for more information on CLLI codes or go to www.commonlanguage.com/clli.

Element Rules:

Required as specified in BR 795-100-100.

Element: 3

CLLI Network Site Code

Appearance

Mode

Min

Max

Series

Range

Required

Alphabetic or Numeric

2

2

No

No

Reference:

See BR 795-100-100 for more information on CLLI codes or go to www.commonlanguage.com/clli.

Element Rules:

Required as specified in BR 795-100-100.

Element: 4

CLLI Network Entity Code

Appearance

Mode

Min

Max

Series

Range

Required

Alphanumeric

3

3

No

No

Reference:

See BR 795-100-100 for more information on CLLI codes or go to www.commonlanguage.com/clli.

Element Rules:

Required as specified in BR 795-100-100.

No.

Element Combination

Series

Separator

1.

1  2  3  4

2

SP


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: S&E - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

P

P

O

O

O

P

P

P

Action Codes

I

-

-

O

I,O, R,D, E,C, T

I,O, R,D, E,C, T

-

-

-


CRIS

CABS

Data Retention

No

Yes

Printed on CSR

No

Yes




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.




iconectiv Confidential - Restricted Access

This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv.

Licensed Material - Property of iconectiv