MBCT

MAKE BUSY CALL TERMINATION TYPE

INDICATES:

The call termination to be given for a Make Busy Scan Point, Make Busy Subgroup or Make Busy Terminal served by a 5ESS.

DATE:

3/17/2005

BILLING:

CRIS

APPLICATIONS:

5ESS, ISDN BRI


SECTION - POSITION

EXAMPLES

S&E - FL

I1   @@A/TN 732 555-1234/MBCT
     CALLTERM.HUNT; MKBTYPE.RANDOM;
     RNDOWNER.2015; SUBGROUP.255

FID RULES/CONSTRAINTS:

  1. When the attribute name and value of MKBTYPE.RANDOM appear (Elements 1 and 3),the attribute name of SUBGROUP and its value (Elements 1 and 5) must appear.

REFERENCES:

  1. Lucent Technologies 235-118-257, View 3.9, Keywords CALLTERMTYPE, MKBTYPE, RNDOWNER, SUBGP, TERM

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - FL

Required

Alphanumeric

39

64

Element: 1

Make Busy Call Termination Type Attribute Name

Appearance

Mode

Min

Max

Series

Range

Required

Alphabetic

7

8

No

No

Code Set:

CodeMeaning
CALLTERMCall Termination Type
MKBTYPEMake Busy Key Type
RNDOWNERRandom Make Busy Key Owner
SUBGROUPMake Busy Subgroup TER Number

Element Rules:

Code sets CALLTERM, MKBTYPE and RNDOWNER are required with each appearance of this FID.

Element: 2

Call Termination Type Attribute Value

Appearance

Mode

Min

Max

Series

Range

Required

Alphabetic

4

7

No

No

Code Set:

CodeMeaning
HUNT
NONHUNT
BOTH

Element: 3

Make Busy Key Type Attribute Value

Appearance

Mode

Min

Max

Series

Range

Required

Alphabetic

6

8

No

No

Code Set:

CodeMeaning
MEMBERMember Make Busy
POSITIONPosition Make Busy
RANDOMRandom Make Busy

Element: 4

Random Make Busy Key Owner Attribute Value

Appearance

Mode

Min

Max

Series

Range

Required

Numeric

1

4

No

No

Data Parameters:

1-2015

Element: 5

Make Busy Subgroup Number Attribute Value

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

3

No

No

Data Parameters:

1-255

No.

Element Combination

Series

Separator

1.

1 . 2 ; SP 1 . 3 ; SP 1 . 4

No

2.

1 . 2 ; SP 1 . 3 ; SP 1 . 4 ; SP 1 . 5

No


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: S&E - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

O

P

P

Action Codes

I,E

I,E

O,D

O,D

I,O, C,T, E,D, M,X, R

I,O, C,T, E,D, M,X, R

I,O, C,T, R

-

-


CRIS

CABS

Data Retention

Yes

No

Printed on CSR

Yes

No




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.




iconectiv Confidential - Restricted Access

This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv.

Licensed Material - Property of iconectiv

Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv.