MCDU

MAXIMUM NUMBER OF CONCURRENT DATA UNITS INDICATOR

INDICATES:

The maximum number of concurrent data units.

DATE:

7/7/2005

BILLING:

CRIS and CABS

APPLICATIONS:

Access Service, Switched Multimegabit Data Service (SMDS)


SECTION - POSITION

EXAMPLES

S&E - FL

I1   @@F/CLS 10.HIXX.123456..NJ
     /MCDU 2

            or

I1   @@F/CLS 10.HFGN.123456..NJ
     /MCDU 512

FID RULES/CONSTRAINTS:

  1. T, F, and X order types prohibited for Access Service application.
  2. X action code prohibited on Access Service orders.

SERVICE ORDER ACTIVITY NOTES:

  1. MCDU represents the maximum number of concurrent data units that can be transmitted over a Switched Multimegabit Data Service (SMDS) Subscriber Network Interface (SNI) circuit from the SMDS Switch Network Element (SS NE) to the customer premise equipment (CPE) and vice versa.
  2. Access
    For Exchange Access SMDS (XA-SMDS), MCDU represents the maximum number of concurrent data units that can be transmitted in one direction over the Inter-carrier Interface (ICI) transmission path.

REFERENCES:

  1. TR-TSV-000772, Generic System Requirements in Support of Switched Multimegabit Data Service.
  2. TR-TSV-000774, SMDS Operations Technology Network Element Generic Requirements.
  3. GR-1060, Switched Multimegabit Data Service (SMDS) Generic Requirements for Exchange Access and Intercompany Serving Arrangements.

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - FL

Required

Numeric

1

3

Element: 1

Maximum Number of Concurrent Data Units Indicator

Appearance

Mode

Min

Max

Series

Range

Required

Numeric

1

3

No

No

Code Set:

CodeMeaning
11 MCDU (CPE to SS NE) 1 MCDU (SS NE to CPE)
216 MCDU (CPE to SS NE) 16 MCDU (SS NE to CPE)
31 MCDU (CPE to SS NE) 16 MCDU (SS NE to CPE)
416 MCDU (CPE to SS NE) 1 MCDU (SS NE to CPE)
128128 MCDU (ICI)
512512 MCDU (ICI)

ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: S&E - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

O

P

P

Action Codes

I,E

I,E

O,D

O,D

I,O, C,T, M,X, D,E, R

I,O, C,T, M,X, D,E, R

I,O, C,T, R

-

-


CRIS

CABS

Data Retention

Yes

Yes

Printed on CSR

Yes

Yes




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.




iconectiv Confidential - Restricted Access

This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv.

Licensed Material - Property of iconectiv

Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv.