MIL

MILEAGE INDICATOR

INDICATES:

Customer location address and mileage specified in increments such as quarter miles, bands, etc., from a customer location to a serving wire center.

DATE:

9/25/2008

BILLING:

CRIS and CABS

APPLICATIONS:

Centrex


SECTION - POSITION

EXAMPLES

IDENT - LH

MIL  AA, 043
MIL  A, 2-MAIN ST

IDENT - FL

     /MIL CCC, 052

S&E - FL

I1   @@K/MIL 01
I1   @@K/MIL A

FID RULES/CONSTRAINTS:

  1. T, F and  X order types prohibited for Access Service application.
  2. X action code prohibited on Access Service orders.
  3. Section:  IDENT,  Position:  LH, FL
    The absence of an action code infers the presence of an "I" (IN) action code. The I action code is optional on the service order.

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

IDENT - LH

Required

Alphanumeric

1

38

Element: 1

Customer Building Indicator

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

1

4

No

No

Data Parameters:

Data characteristics are locally developed.

Element: 2

Mileage Increments

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

5

No

No

Data Parameters:

Data characteristics are locally developed.

Element: 3

Station Line Address

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

4

26

No

No

Symbols:

Ampersand, Apostrophe, Asterisk, At Sign, Hyphen, Space

No.

Element Combination

Series

Separator

1.

1

No

2.

1 , SP 2

No

3.

1 , SP 2 - 3

No

4.

2

No


SECTION - POSITION

IDENT - FL

Please refer to IDENT - LH for all data requirements.


SECTION - POSITION

S&E - FL

Please refer to IDENT - LH for all data requirements.


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: IDENT - LH

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

O

P

P

Action Codes

I

I

I,O

I,O

I,O

I,O

I

-

-


CRIS

CABS

Data Retention

Yes

Yes

Printed on CSR

Yes

Yes

Order Section - Position: IDENT - FL

 

Please refer to IDENT - LH for Order Type, Action Code, and FID relationships.

Order Section - Position: S&E - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

O

P

P

Action Codes

I,E

I,E

O,D

O,D

I,O, C,T, D,E, M,X, R

I,O, C,T, D,E, M,X, R

I,O, C,T, R

-

-


CRIS

CABS

Data Retention

Yes

Yes

Printed on CSR

Yes

Yes




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.




iconectiv Confidential - Restricted Access

This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv.

Licensed Material - Property of iconectiv

Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv.