MW

MODULAR WIRING

INDICATES:

Modular wiring information.  The use of MW causes additions and/or deletions to the Modular Wiring Record.

DATE:

1/1/1988

BILLING:

CRIS

APPLICATIONS:

General Purpose


SECTION - POSITION

EXAMPLES

S&E - LH

First and only line at the premises
IMW  KW, &M, C, Y
IMW  CPW
IMW  KW, &B, D-CPW/DPA 1-700 PINE
IMW  KW, D, B, Y, Z/AI T

Additional line modular wiring entry
IMW  2-B1, B2/TN 397-7073

Two or more lines with associated
modular wiring arrangements.

IMW  KW, D, B1, B2, Y
IMW  2-B3, Y/TN 391-1095

Advance Jacking with different modular
group of units.

IMW  L, B/LOC APT 100-109
IMW  L, B, KW/LOC APT 200-209

FID RULES/CONSTRAINTS:

  1. FID's that may float behind MW are AI, DPA, LOC, and TN.

SERVICE ORDER ACTIVITY NOTES:

  1. CPW appears as a single modular wiring description when the customer provides and installs all of the modular wiring.  CPW appears with the precise location indicator (Room Location Code and Numeric Identifier, when applicable) that signifies the demarcation point from where the customer provides and installs modular wiring.
  2. Two or more modular wiring entries may appear on the same service order.  For example on:

    -  Orders for more than one line.

    -  Prewire orders for advance jacking with different modular wiring arrangements for each unit or group of units.

    The additional line reference number,when applicable, must precede all modular wiring elements.

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - LH

Required

Alphanumeric

1

18

Element: 1

Additional Line(s) Reference Number

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

2

No

No

Data Parameters:

1-99

Element Rules:

Required when any of the other 3 elements are associated with additional lines. Hyphen separates element 1 from elements 3 and 4, and from one of 4 of element 2's subelements: Quantity of Jacks, Four Pin Jack, Room Location Code or Customer Provided Wire Indicator.

Element: 2

Modular Wiring Description

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic or Numeric

1

9

Yes

No

Symbols:

Hyphen

Element Rules:

Hyphen separates the subelements Room Location Code, Room Location Numeric Identifier, or Wall Mounted Jack from the Customer Provided Wire Indicator. Modular Wiring Description consists of 6 subelements:
DATA ENTRY                                                    MODE       MIN       MAX
a.  Quantity of  Jacks                                             N              1            2
(OPTIONAL - Required when a
room has two or more
modular outlets)
Complete List:   2-99
b.  Four Pin Jack                                                A or N          1            1
(OPTIONAL - Required
when a four - pin jack is
to be installed and is mutually
exclusive with Subelement 2e,
Wall Mounted Jack)
Complete List: & - Four-Pin Jack
c.  Room Location Code                                         A              1            1         
(OPTIONAL - Required when the
Permanently Assigned
Outside Plant Indicator or the
Customer Provided Wiring
Indicator does not appear)  
Complete List:
J - Adjacent Building
A - Attic
C - Basement (Cellar)
B - Bedroom
T - Bathroom
E - Dockside
N - Den
D - Dining Room
F - Family Room
G - Garage
H - Hallway (Hall)
K - Kitchen
L - Living Room
M - Master Bedroom
P - Patio or Porch
S - Poolside
R - Recreation Room
W - Work Room (Shop)
U - Laundry Room
V - Utility Room
O - Other
d.  Room Location Numeric Identifier                        N              1            1
(OPTIONAL - Required when a Room
Location Code must appear more than
once on the on the same logical line)
Complete List: 1-9
e.  Wall Mounted Jack                                            A              1            1
(OPTIONAL - Required when
a wall mounted jack is to be
installed and is mutually
exclusive with Sub- element 2b,
Four-Pin Jack)
Complete List: W - Wall Mounted Jack
f.  Customer Provided Wiring Indicator                      A              3           3
(OPTIONAL - Required when all or
part of the premises wire
is provided by the customer)
Complete List: CPW

Element: 3

Permanently Assigned Outside Plant Indicator

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

1

1

No

No

Code Set:

CodeMeaning
Y

Element Rules:

Required when dedicated Outside Plant has been assigned.

Element: 4

Centralized Transformer Indicator

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

1

1

No

No

Code Set:

CodeMeaning
Z

Element Rules:

Required when a centralized transformer is on the customer's premises.

No.

Element Combination

Series

Separator

1.

1 - 2

No

2.

1 - 2 , SP 3

No

3.

1 - 2 , SP 3 , SP 4

No

4.

1 - 2 , SP 4

No

5.

1 - 3

No

6.

1 - 3 , SP 4

No

7.

2

Yes

, SP

8.

2 , SP 3

No

9.

2 , SP 3 , SP 4

No

10.

2 , SP 4

No

11.

3

No

12.

3 , SP 4

No


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: S&E - LH

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

O

O

O

Action Codes

I

I

O

O

I,O

I,O

I,O

I

O


CRIS

CABS

Data Retention

No

No

Printed on CSR

No

No




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.