MWC |
MULTIWAY CALLING |
INDICATES: |
The Multiway Calling feature name(s) and optional line attributes to be assigned to a line served by a Stored Program Controlled Switch (SPCS). |
DATE: |
3/16/2006 |
BILLING: |
CRIS and CABS |
APPLICATIONS: |
5ESS, Access Service, Centrex, DMS-100, EWSD, FETEX-150, ISDN BRI, Open Network Architecture, STROM-DCO, TL1 |
SECTION - POSITION |
EXAMPLES |
S&E - LH |
|
DMS-100 |
|
S&E - FL |
|
5ESS |
FID RULES/CONSTRAINTS: |
|
REFERENCES: |
|
SECTION - POSITION |
APPEARANCE |
MODE |
MIN |
MAX |
S&E - LH |
Required |
Alphanumeric |
3 |
49 |
Element: 1 |
Multiway Calling Feature List Number |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Required |
Numeric |
1 |
3 |
No |
No |
Data Parameters: |
||
|
Element: 2 |
Multiway Calling Feature Name (DMS-100) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphanumeric |
1 |
8 |
Yes |
No |
Element Rules: |
Semicolon space is the series separator. |
Element: 3 |
Multiway Calling Attribute Name (DMS-100) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphanumeric |
8 |
8 |
No |
No |
Element: 4 |
Multiway Calling Attribute Value (DMS-100) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphanumeric |
1 |
15 |
No |
No |
Element Rules: |
When element 4 appears, element 3 is required. |
Element: 5 |
Three-Way Calling with Public Announcement (3WCPUB) Feature Name (DMS-100) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphanumeric |
6 |
6 |
No |
No |
Code Set: |
||||
|
Element: 6 |
3WCPUB Loop Console Attribute Name (DMS-100) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphabetic |
5 |
5 |
No |
No |
Code Set: |
||||
|
Element: 7 |
3WCPUB Loop Console Attribute Value (DMS-100) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphabetic |
1 |
1 |
No |
No |
Code Set: |
||||||
|
Element: 8 |
3WCPUB Split Key Attribute Name (DMS-100) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphabetic |
6 |
6 |
No |
No |
Code Set: |
||||
|
Element Rules: |
Element is required when element 7 code set Y is used. |
Element: 9 |
3WCPUB Split Key Attribute Value (DMS-100) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphabetic |
3 |
4 |
No |
No |
Code Set: |
||||||
|
Element Rules: |
Element is required when element 8 is used. |
Element: 10 |
Multiway Calling Attribute Name (TL1, FETEX-150) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphabetic |
3 |
6 |
Yes |
No |
Code Set: |
||||||||||||||||||||
|
Element Rules: |
When code set CTTL appears, code set CTA, CTIO, or CTIG is required. |
Element: 11 |
Add-on Consultation Hold Attribute Value (FETEX-150) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphabetic |
4 |
4 |
No |
No |
Code Set: |
||||
|
Element: 12 |
Multiway Calling Feature Name (EWSD) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphabetic |
2 |
5 |
Yes |
No |
Code Set: |
||||||||||||||||||
|
Element Rules: |
Semicolon space is the series separator. |
Element: 13 |
Multiway Calling Feature Name (5ESS) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphanumeric |
1 |
8 |
Yes |
No |
Code Set: |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Element Rules: |
||
|
Element: 14 |
Multiway Calling Attribute Name (5ESS) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphabetic |
8 |
8 |
No |
No |
Code Set: |
||||||
|
Element: 15 |
NWAYSIZE Attribute Value (5ESS) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
1 |
1 |
No |
No |
Data Parameters: |
||||
|
Element: 16 |
DIRCONDN Attribute Value (5ESS) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphanumeric |
1 |
15 |
No |
No |
Data Parameters: |
||
|
Symbols: |
Asterisk, Number Sign |
No. |
Element Combination |
Series |
Separator |
1. |
1 - 2 |
No |
|
2. |
1 - [ 2 SP [ 3 . 4 , SP ] ; SP ] |
No |
|
3. |
1 - 5 SP 6 . 7 |
No |
|
4. |
1 - 5 SP 6 . 7 , SP 8 . 9 |
No |
|
5. |
1 - 10 |
No |
|
6. |
1 - 10 . 11 |
No |
|
7. |
1 - 12 |
No |
|
8. |
1 - 13 |
No |
|
9. |
1 - [ 13 SP 14 . 15 ; SP ] |
No |
|
10. |
1 - [ 13 SP 14 . 15 , SP 14 . 16 ; SP ] |
No |
|
11. |
1 - [ 13 SP 14 . 16 ; SP ] |
No |
SECTION - POSITION |
APPEARANCE |
MODE |
MIN |
MAX |
S&E - FL |
Required |
Alphanumeric |
1 |
45 |
Element: 1 |
Multiway Calling Feature List Number (DMS-100, 5ESS) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
1 |
3 |
No |
No |
Data Parameters: |
||
|
Element Rules: |
When element 1 is used, there must be a corresponding LH entry. |
Element: 2 |
Multiway Calling Feature Name (DMS-100) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphanumeric |
1 |
8 |
Yes |
No |
Element Rules: |
||
|
Element: 3 |
Multiway Calling Attribute Name (DMS-100) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphanumeric |
8 |
8 |
No |
No |
Element: 4 |
Multiway Calling Attribute Value (DMS-100) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphanumeric |
1 |
15 |
No |
No |
Element Rules: |
When element 4 appears, element 3 is required. |
Element: 5 |
Three-Way Calling with Public Announcement (3WCPUB) Feature Name (DMS-100) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphanumeric |
6 |
6 |
No |
No |
Code Set: |
||||
|
Element: 6 |
3WCPUB Loop Console Attribute Name (DMS-100) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphabetic |
5 |
5 |
No |
No |
Code Set: |
||||
|
Element: 7 |
3WCPUB Loop Console Attribute Value (DMS-100) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphabetic |
1 |
1 |
No |
No |
Code Set: |
||||||
|
Element: 8 |
3WCPUB Split Key Attribute Name (DMS-100) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphabetic |
6 |
6 |
No |
No |
Code Set: |
||||
|
Element Rules: |
Element is required when element 7 code set Y is used. |
Element: 9 |
3WCPUB Split Key Attribute Value (DMS-100) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphabetic |
3 |
4 |
No |
No |
Code Set: |
||||||
|
Element Rules: |
Element is required when element 8 is used. |
Element: 10 |
Multiway Calling Attribute Name (TL1, FETEX-150, DCO) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphabetic |
3 |
6 |
Yes |
No |
Code Set: |
||||||||||||||||||||
|
Element Rules: |
||
|
Element: 11 |
Add-on Consultation Hold Attribute Name (FETEX-150) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphabetic |
4 |
4 |
No |
No |
Code Set: |
||||
|
Element: 12 |
Multiway Calling Feature Name (EWSD) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphabetic |
2 |
5 |
Yes |
No |
Code Set: |
||||||||||||||||||
|
Element Rules: |
||
|
Element: 13 |
Multiway Calling Feature Name (5ESS) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphanumeric |
1 |
8 |
Yes |
No |
Code Set: |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Element Rules: |
||
|
Element: 14 |
Multiway Calling Attribute Name (5ESS) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphabetic |
8 |
8 |
No |
No |
Code Set: |
||||||
|
Element: 15 |
NWAYSIZE Attribute Value (5ESS) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
1 |
1 |
No |
No |
Data Parameters: |
||||
|
Element: 16 |
DIRCONDN Attribute Value (5ESS) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphanumeric |
1 |
15 |
No |
No |
Data Parameters: |
||
|
Symbols: |
Asterisk, Number Sign |
No. |
Element Combination |
Series |
Separator |
1. |
1 |
No |
|
2. |
2 |
Yes |
; SP |
3. |
2 SP [ 3 . 4 , SP ] |
Yes |
; SP |
4. |
5 SP 6 . 7 |
No |
|
5. |
5 SP 6 . 7 , SP 8 . 9 |
No |
|
6. |
10 |
Yes |
, SP |
7. |
10 . 11 |
No |
|
8. |
12 |
Yes |
; SP |
9. |
13 |
Yes |
; SP |
10. |
13 SP 14 . 15 |
Yes |
; SP |
11. |
13 SP 14 . 15 , SP 14 . 16 |
Yes |
; SP |
12. |
13 SP 14 . 16 |
Yes |
; SP |
ORDER TYPE/ACTION CODE/FID RELATIONSHIPS |
Order Section - Position: S&E - LH
|
Order Type |
N |
T |
F |
D |
C |
R |
X |
P |
A |
Presence |
O |
O |
O |
O |
O |
O |
O |
P |
P |
Action Codes |
I,E |
I,E |
O,D |
O,D |
I,O, C,T, E,D, R |
I,O, C,T, E,D, R |
I,O |
- |
- |
CRIS |
CABS |
|
Data Retention |
Yes |
No |
Printed on CSR |
Yes |
No |
Order Section - Position: S&E - FL
|
Order Type |
N |
T |
F |
D |
C |
R |
X |
P |
A |
Presence |
O |
O |
O |
O |
O |
O |
O |
P |
P |
Action Codes |
I,E |
I,E |
O,D |
O,D |
I,O, C,T, E,D, M,X, R |
I,O, C,T, E,D, M,X, R |
I,O, C,T, R |
- |
- |
CRIS |
CABS |
|
Data Retention |
Yes |
Yes |
Printed on CSR |
Yes |
Yes |
Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure. |
iconectiv Confidential - Restricted Access This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv. |
Licensed Material - Property of iconectiv Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv. |