MWS

MODULAR WIRING SUMMARY

INDICATES:

A summary of modular wiring information. The use of MWS does not affect the Modular Wiring Record.

DATE:

1/1/1988

BILLING:

CRIS

APPLICATIONS:

General Purpose


SECTION - POSITION

EXAMPLES

S&E - LH

First and only line at the premises
IMWS KW, &M, C, Y
IMWS CPW
IMWS KW, &B, D-CPW/DPA 1-700 PINE
IMWS KW, D, B, Y, Z/AI T

Additional line modular wiring entry
IMWS 2-B1, B2/TN 397-7073

Two or more lines with associated
modular wiring arrangements.

IMWS KW, D, B1, B2, Y
IMWS 2-B3, Y/TN 391-1095

Advance Jacking with different modular
group of units.

IMWS L, B/LOC APT 100-109
IMWS L, B, KW/LOC APT 200-209

FID RULES/CONSTRAINTS:

  1. FIDs that may float behind MWS are AI, DPA, LOC and TN.

SERVICE ORDER ACTIVITY NOTES:

  1. CPW appears as a single Modular Wiring Description when the customer provides and installs all of the modular wiring.  CPW appears with the precise location indicator (Room Location Code and Numeric Identifier, when applicable) that signifies the demarcation point from where the customer provides and installs modular wiring     
  2. Two or more Modular Wiring entries may appear on the same service order.  For example on:
         -  Orders for more than one line
         -  Prewire orders for advance jacking with different modular wiring arrangements for each unit or group of units

    The Additional Line Reference Number, when applicable, must precede all Modular Wiring elements.

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - LH

Required

Alphanumeric

1

18

Element: 1

Additional Line(s) Reference Number

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

2

No

No

Data Parameters:

1-99

Element Rules:

Required when any of the other 3 elements are associated with additional lines. Hyphen separates element 1 from elements 3 and 4, and from one of 4 of element 2's subelements: Quantity of Jacks, Four Pin Jack, Room Location Code or Customer Provided Wire Indicator.

Element: 2

Modular Wiring Description

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic or Numeric

1

9

Yes

No

Symbols:

Hyphen

Element Rules:

Hyphen separates the subelements Room Location Code, Room Location Numeric Identifier, or Wall Mounted Jack from the Customer Provided Wire Indicator. Modular Wiring Description consists of 6 subelements:
DATA ENTRY                                                  MODE         MIN       MAX
a.  Quantity of Jacks                                            N                1           2
(OPTIONAL - Required when
a room has two or more
modular outlets)
Complete List:  2-99
b.  Four Pin Jack                                               A or N           1           1
(OPTIONAL - Required when
a four-pin jack is to be
installed and is mutually exclusive
with Subelement 2e,
Wall Mounted Jack)
Complete List:
& - Four-Pin Jack
c.  Room Location Code                                        A               1           1
(OPTIONAL - Required when
the Permanently Assigned
Outside Plant Indicator or the
Customer Provided Wiring
Indicator does not appear)
Complete List:
J - Adjacent Building
A - Attic
C - Basement (Cellar)
B - Bedroom
T - Bathroom
E - Dockside
N - Den
D - Dining Room
F - Family Room
G - Garage
H - Hallway (Hall)
K - Kitchen
L - Living Room
M - Master Bedroom
P - Patio or Porch
S - Poolside
R - Recreation Room
W - Work Room (Shop)
U - Laundry Room
V - Utility Room
O - Other
d.  Room Location Numeric Identifier                      N               1            1
(OPTIONAL - Required when a
Room Location Code
must appear more than once
on the same logical line)
Complete List: 1-9
e.  Wall Mounted Jack                                           N              1           1
(OPTIONAL - Required when
a wall mounted jack  
is to be installed and
is mutually exclusive with
Subelement 2b, Four-Pin Jack)
Complete List:
W - Wall Mounted Jack
f.  Customer Provided Wiring Indicator                     A               3           3
(OPTIONAL - Required when all
or part of the premises
wire is provided by the
customer)
Complete List: CPW

Element: 3

Permanently Assigned Outside Plant Indicator

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

1

1

No

No

Element Rules:

Required when dedicated Outside Plant has been assigned.

Element: 4

Centralized Transformer Indicator

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

1

1

No

No

Element Rules:

Required when a centralized transformer is on the customer's premises.

No.

Element Combination

Series

Separator

1.

1 - 2

No

2.

1 - 2 , SP 3

No

3.

1 - 2 , SP 3 , SP 4

No

4.

1 - 2 , SP 4

No

5.

1 - 3

No

6.

1 - 3 , SP 4

No

7.

2

Yes

, SP

8.

2 , SP 3

No

9.

2 , SP 3 , SP 4

No

10.

2 , SP 4

No

11.

3

No

12.

3 , SP 4

No


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: S&E - LH

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

O

P

P

Action Codes

I

I

O

O

I,O, C,T

I,O, C,T

I,O

-

-


CRIS

CABS

Data Retention

No

No

Printed on CSR

No

No




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.




iconectiv Confidential - Restricted Access

This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv.

Licensed Material - Property of iconectiv

Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv.