NFE

NETWORK FACILITIES EXISTING

INDICATES:

The total number of network line(s) that did not require field work to establish.

DATE:

11/18/1993

BILLING:

CRIS and CABS

APPLICATIONS:

General Purpose


SECTION - POSITION

EXAMPLES

STAT - LH

NFE  1

STAT - FL

     /NFE 4

FID RULES/CONSTRAINTS:

  1. T, F, and X order types prohibited for Access Service application.

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

STAT - LH

Required

Numeric

1

4

Element: 1

Number of Lines/Circuits

Appearance

Mode

Min

Max

Series

Range

Required

Numeric

1

4

No

No

Data Parameters:

1-9999

SECTION - POSITION

STAT - FL

Please refer to STAT - LH for all data requirements.


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: STAT - LH

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

P

O

P

P

Action Codes

-

-

-

-

-

-

-

-

-

Other FIDs Required Same Section

COC OR OCB

COC OR OCB

COC OR OCB

COC OR OCB

COC OR OCB

-

COC OR OCB

-

-


CRIS

CABS

Data Retention

No

No

Printed on CSR

No

No

Order Section - Position: STAT - FL

 

Please refer to STAT - LH for Order Type, Action Code, and FID relationships.




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.




iconectiv Confidential - Restricted Access

This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv.

Licensed Material - Property of iconectiv

Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv.