NHN

NON-HUNTING NUMBER

INDICATES:

Non-hunting telephone numbers in Stored Program Controlled Switch (SPCS) multiline hunt groups.

DATE:

10/31/2014

BILLING:

CRIS and CABS

APPLICATIONS:

1AESS, 2ESS, 5ESS, Access Service, Access Service Request (ASR), EWSD, Hunting, ISDN BRI, TL1


SECTION - POSITION

EXAMPLES

S&E - FL

Non-hunting Telephone Numbers
I1   @@A/TER 3/NHN 732 555-8800/HML 20
     /TLI 732 555-6400

Hunting and Non-hunting Telephone Number on the same access line
I1   @@A/TER 1/TN 732 555-6400/HML 20
     /NHN 732 555-8758/TLI 732 555-6400

ASGM - FL

IOE  11-100-200/TER 1/TLI 732 555-1234
     /NHN 732 555-2345

FID RULES/CONSTRAINTS:

  1. A multiline hunt group may contain one or more lines which do not hunt.  The NHN FID must appear following each line USOC for which a non-hunting telephone number is to be assigned.
  2. One Terminal (TER) in a multiline group may have two telephone numbers assigned to it; one for hunting using the Telephone Number (TN) FID and one for non-hunting using the FID NHN.
  3. In the EWSD Integrated Services Digital Network (ISDN) switch, a TN must be assigned to TER 1 and it must be the pilot TN for the hunt group.  TER 1 may also have an optional non-hunt TN identified with the NHN FID.  For other than TER 1, a TN may be assigned (but not required) and can be either a hunt TN or a non-hunt TN identified with the NHN FID.  TN and NHN are mutually exclusive for other than TER 1.  For Electronic Key Telephone System (EKTS) Call Appearance Hunting, all TNs are hunt TNs and the NHN FID is prohibited.
  4. Section:  ASGM      Position:  FL
    This FID is entered in the Central Office Facilities Subset.
  5. DMS-100
    Non-hunt numbers are not allowed in a multiline hunt group.
  6. Section:  S&E       Position:  FL
    T, F, and X order types prohibited for Access Service application.
  7. Section:  S&E       Position:  FL
    X action code prohibited on Access Service orders.
  8. SERIES AND RANGE ENTRIES - PROCESSING
    Service Order Analysis and Control System (SOAC) should process series and range data entires using the DISTRIBUTE algorithm.

REFERENCES:

  1. 5ESS
    Lucent Technologies, 235-118-257, Views 1.6 and 23.2, Keyword NONHUNT
  2. TL1
    TR-NWT-000199, DNCT View, Keyword DNTYP
  3. EWSD
    Siemens 0625-00070 Multiline Hunt Service; Siemens 0770-00010, NONHUNT
  4. EWSD - Release 17.0
    Siemens Telecom Networks Requirement Specification, TL1 for MLHGs, P30310-A2445-A016-02-7626, CUG, DC, DNCT, and OEDN Views, Keywords MLHG and MLTERM
  5. ATIS/OBF-ASR-007 and 011, NHN field

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - FL

Required

Numeric

4

12

Element: 1

Numbering Plan Area Code

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

3

3

No

No

Reference:

See iconectiv LERG Routing Guide for complete list.

Element Rules:

NPA is required when it cannot be derived first from the NPA previously entered on the same logical line, second from the fielded TN, or third from the fielded EX in the Identification section.

Element: 2

Central Office Code

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

3

3

No

No

Reference:

See iconectiv LERG Routing Guide for complete list.

Element Rules:

Central Office Code is required when the NPA is entered, or when it is different from the Central Office Code previously entered on the same logical line, or when the Central Office Code is different from that of the main account number in the fielded TN.

Element: 3

Line Number

Appearance

Mode

Min

Max

Series

Range

Required

Numeric

4

4

Yes

Yes

Data Parameters:

0000-9999

No.

Element Combination

Series

Separator

1.

1 SP 2 - 3

Yes

, SP

2.

2 - 3

Yes

; SP

3.

3

Yes

, SP


SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

ASGM - FL

Required

Numeric

12

12

Element: 1

Numbering Plan Area Code

Appearance

Mode

Min

Max

Series

Range

Required

Numeric

3

3

No

No

Reference:

See iconectiv LERG Routing Guide for complete list.

Element: 2

Central Office Code

Appearance

Mode

Min

Max

Series

Range

Required

Numeric

3

3

No

No

Reference:

See iconectiv LERG Routing Guide for complete list.

Element: 3

Line Number

Appearance

Mode

Min

Max

Series

Range

Required

Numeric

4

4

No

No

Data Parameters:

0000-9999

No.

Element Combination

Series

Separator

1.

1 SP 2 - 3

No


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: S&E - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

O

P

P

Action Codes

I,E

I,E

O,D

O,D

I,O, C,T, M,X, D,E, R

I,O, C,T, M,X, D,E, R

C,T, R

-

-

Other FIDs Required Logical Line

HML TER

HML TER

HML TER

HML TER

HML TER

HML TER

HML TER

-

-


CRIS

CABS

Data Retention

Yes

Yes

Printed on CSR

Yes

Yes

Order Section - Position: ASGM - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

P

O

P

P

Action Codes

I

I

O

O

I,O

-

I,O

-

-


CRIS

CABS

Data Retention

No

No

Printed on CSR

No

No




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.




iconectiv Confidential - Restricted Access

This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv.

Licensed Material - Property of iconectiv

Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv.