OAB

ORDER ASSIGNED BY

INDICATES:

The employee who assigned the order.

DATE:

1/1/1988

BILLING:

CRIS and CABS

APPLICATIONS:

General Purpose


SECTION - POSITION

EXAMPLES

ASGM - LH

OAB  SPC

ASGM - FL

G1   RT 101/RZ 16/PRQ N/OAB JT

FID RULES/CONSTRAINTS:

  1. This FID is entered in the Miscellaneous Subset, Central Office Facility Subset, and Outside Plant Subset.
  2. The LH appearance of this FID is allowed only in the Miscellaneous Subset.
  3. T, F and X order types are prohibited for Access Service application.

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

ASGM - LH

Required

Alphanumeric

1

3

Element: 1

Order Assigned By

Appearance

Mode

Min

Max

Series

Range

Required

Alphanumeric

1

3

No

No

Data Parameters:

Data characteristics are locally developed.

SECTION - POSITION

ASGM - FL

Please refer to ASGM - LH for all data requirements.


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: ASGM - LH

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

R

R

R

R

R

P

R

P

P

Action Codes

I

I

O

O

I,O

-

I,O

-

-


CRIS

CABS

Data Retention

No

No

Printed on CSR

No

No

Order Section - Position: ASGM - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

R

R

R

R

R

P

R

P

P

Action Codes

I

I

O

O

I,O

-

I,O

-

-


CRIS

CABS

Data Retention

No

No

Printed on CSR

No

No




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.




iconectiv Confidential - Restricted Access

This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv.

Licensed Material - Property of iconectiv

Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv.