PAD

PACKET ASSEMBLER/DISASSEMBLER

INDICATES:

The Packet Assembler/Disassembler (PAD) options available for Asynchronous access lines in a Public Packet Switched Network (PPSN).

DATE:

7/21/2005

BILLING:

CRIS

APPLICATIONS:

Local Area Network (LAN), Public Packet Switched Network (PPSN)


SECTION - POSITION

EXAMPLES

S&E - FL

I1   @@V/CLS 10.QSZX.123456..NJ
     /PAD 0 0 126 255 1 1
     21 1 255 255 4 1 P13-4
     P14-127 P15-1 P16-127 P17-127
     P18-127 P19-126 P20-128 P21-1
     P22-255

Data Kit
I1   @@V/CLS 10.QSZX.123456..NJ
     /PAD PI.NAME6,PRC.DLE,ECHO.
     N,DFS.+,ITD.1,FCBD.Y,PSSC.+,
     PORB.ESC,DO.+,LF.255,BS.+,
     FCDK.+,LFI.DATATO,LFP.7,ED.+,
     CD.+,LDEL.+,LDIS.DEL

FID RULES/CONSTRAINTS:

  1. In addition to the combinations shown in the Element Combination Table, the following combinations are allowed:   

    The Consultative Committee on International Telephony and Telegraphy (CCITT) requires the first 12 PAD parameters with the last 13 (P13-P25) parameters optional, in any combination with the first 12. Element 26 - Optional Data Field could be used to portray additional vendor switch specific data in addition to/or in lieu of Elements 13 through 25. Allowable element combinations are vendor switch specific.
  2. Elements 27 and 28 are used to define the Datakit Packet Assembler/Disassembler (PAD) parameters of P1 through P18 for LAN (Local Area Network).
  3. FID and data float on access line (speed) USOC.

REFERENCES:

  1. Refer to TR-NPL-000011 (Asynchronous Terminal and Host Interface Reference) for additional information.

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - FL

Required

Alphanumeric

12

139

Element: 1

P1 Element - PAD Recall

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

3

No

No

Data Parameters:

0, 1, 32-126

Element: 2

P2 Element - Echo

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

1

No

No

Code Set:

CodeMeaning
0No Echo
1Echo

Element: 3

P3 Element - Data Forwarding Character(s)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

3

No

No

Data Parameters:

0, 2, 6, 18, 126

Element: 4

P4 Element - Idle Timer Delay

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

3

No

No

Data Parameters:

0-255

Element: 5

P5 Element - Ancillary Device Control

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

1

No

No

Code Set:

CodeMeaning
0No Use of X-on/X-off
1Use of X-on/X-off (data transfer)
2Use of X-on/X-off (data transfer and command)
5Use of X-on/X-off (data transfer and command) (NTI DPN)

Element: 6

P6 Element - Control of PAD Service Signal

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

2

No

No

Data Parameters:

0, 1, 5, 8-15

Element: 7

P7 Element - Break Signal PAD Operational Procedures

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

2

No

No

Data Parameters:

0, 1, 2, 5, 8, 21

Element: 8

P8 Element - Discard Output

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

1

No

No

Code Set:

CodeMeaning
0Normal Delivery
1Discard Output

Element: 9

P9 Element - Padding After Carriage Return

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

3

No

No

Data Parameters:

0-255

Element: 10

P10 Element - Line Folding

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

3

No

No

Data Parameters:

0-255

Element: 11

P11 - Element Binary Speed

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

2

No

No

Data Parameters:

0-18, 99

Element: 12

P12 Element - Flow Control

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

1

No

No

Code Set:

CodeMeaning
0No use of X-on/X-off for Flow Control
1Use of X-on/X-off for Flow Control

Element: 13

P13 Element - Line Feed Insertion

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

5

6

No

No

Data Parameters:

P13-0, P13-1, P13-2, P13-4, P13-5, P13-6, P13-7, P13-16, P13-17, P13-20, P13-21, P13-22, P13-23

Symbols:

Hyphen

Element: 14

P14 Element - Padding After Line Feed

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

5

7

No

No

Data Parameters:

P14-0 thru P14-255

Symbols:

Hyphen

Element: 15

P15 - Element Editing

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

5

5

No

No

Data Parameters:

P15-0No use of Editing in Data transfer state
P15-1Use of Editing in Data transfer state

Symbols:

Hyphen

Element: 16

P16 Element - Character Delete

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

5

7

No

No

Data Parameters:

P16-0 thru P16-127

Symbols:

Hyphen

Element: 17

P17 Element - Line Delete

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

5

7

No

No

Data Parameters:

P17-0 thru P17-127

Symbols:

Hyphen

Element: 18

P18 Element - Line Display

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

5

7

No

No

Data Parameters:

P18-0 thru P18-127

Symbols:

Hyphen

Element: 19

P19 Element - Editing PAD Service Signal

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

5

7

No

No

Data Parameters:

P19-0, P19-1, P19-2, P19-8, P19-32 thru P19-126

Symbols:

Hyphen

Element: 20

P20 Element - Echo Mask

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

5

7

No

No

Data Parameters:

P20-0, P20-1, P20-2, P20-4, P20-8, P20-16, P20-32, P20-64, P20-128

Symbols:

Hyphen

Element: 21

P21 Element - Parity Treatment

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

5

5

No

No

Data Parameters:

P21-0No Parity Detection or Generation
P21-1Parity Checking
P21-2Parity Generation
P21-3Parity Detection and Generation

Symbols:

Hyphen

Element: 22

P22 Element - Page Wait

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

5

7

No

No

Data Parameters:

P22-0 thru P22-255

Symbols:

Hyphen

Element: 23

P121 Element - Additional Forwarding Signal 1

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

6

8

No

No

Data Parameters:

P121-0 thru P121-127

Symbols:

Hyphen

Element: 24

P122 Element - Additional Forwarding Signal 2

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

6

8

No

No

Data Parameters:

P122-0 thru P122-127

Symbols:

Hyphen

Element: 25

P125 Element - Output Pending Timer

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

6

8

No

No

Data Parameters:

P125-0 thru P125-255

Element: 26

Optional Data Field

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

1

50

No

No

Data Parameters:

Data characteristics are locally developed based on vendor switch.

Element: 27

Pad Parameter Name (Datakit)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

2

4

No

No

Code Set:

CodeMeaning
PIProfile Identifier
PRCP1 Pad Recall Character
ECHOP2 Echo
DFSP3 Data Forwarding Signal
ITDP4 Idle Timer Delay
FCDVP5 Flow Control by Device
PSSCP6 Pad Service Signal Control
PORBP7 Pad Operation on Receipt of Break
DOP8 Discard Output
PACRP9 Padding After Carriage Return
LFP10 Line Folding
BSP11 Binary Speed
FCDKP12 Flow Control by Datakit
LFIP13 Line Feed Insertion
LEPP14 Line Feed Padding
EDP15 Editing
CDP16 Character Delete
LDELP17 Line Delete
LDISP18 Line Display

Element Rules:

When Element 27 appears, Elements 1 through 26 are prohibited.

Element: 28

Pad Parameter Value (Datakit)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

1

20

No

No

Data Parameters:

Data characteristics are locally developed.

Symbols:

At Sign, Plus Sign

Element Rules:

Plus sign is used to indicate Datakit default.
When Element 27 appears, Element 28 is required.

No.

Element Combination

Series

Separator

1.

27 . 28

Yes

,


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: S&E - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

P

P

P

Action Codes

I,E

I,E

O,D

O,D

I,O, C,T, D,E, R

I,O, C,T, D,E, R

-

-

-

Other FIDs Prohibited Logical Line

PDP

PDP

PDP

PDP

PDP

PDP

-

-

-


CRIS

CABS

Data Retention

Yes

No

Printed on CSR

Yes

No




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.




iconectiv Confidential - Restricted Access

This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv.

Licensed Material - Property of iconectiv

Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv.