PDP

PREDEFINED/STANDARD PROFILE

INDICATES:

The predefined or standard profile options for asynchronous access lines in a Public Packet Switched Network (PPSN).

DATE:

7/21/2005

BILLING:

CRIS and CABS

APPLICATIONS:

Public Packet Switched Network (PPSN)


SECTION - POSITION

EXAMPLES

S&E - FL

I1   @@H/CLS QSHX.123456..NJ
     /DTN 732 555-1234/PDP 1

FID RULES/CONSTRAINTS:

  1. T, F and X order types prohibited for Access Service application.
  2. X action codes are prohibited on Access Service orders.

SERVICE ORDER ACTIVITY NOTES:

  1. FID and data float on logical line for asynchronous speed or exchange/switch termination USOC.

REFERENCES:

  1. Refer to TR-NPL-000011 (Asynchronous Terminal and Host Interface Reference) for additional information.

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - FL

Required

Numeric

1

3

Element: 1

Predefined/Standard Profile Options

Appearance

Mode

Min

Max

Series

Range

Required

Numeric

1

3

No

No

Data Parameters:

0-999

Element Rules:

Data characteristics are locally developed based on vendor switch.


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: S&E - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

O

P

P

Action Codes

I,E

I,E

O,D

O,D

I,O, C,T, D,E, R,X, M

I,O, C,T, D,E, R,X, M

C,T, R

-

-

Other FIDs Prohibited Logical Line

PAD

PAD

PAD

PAD

PAD

PAD

PAD

-

-


CRIS

CABS

Data Retention

Yes

Yes

Printed on CSR

Yes

Yes




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.




iconectiv Confidential - Restricted Access

This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv.

Licensed Material - Property of iconectiv

Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv.