PFT

POWER FAILURE TRANSFER TO

INDICATES:

That ringing is transferred during a power failure.

DATE:

10/31/2014

BILLING:

CRIS and CABS

APPLICATIONS:

EWSD


SECTION - POSITION

EXAMPLES

S&E - FL

Trunk entry showing Station Line Number to which ringing is transferred
I1   @@A/TN 732 234-2000/PFT PX 211
I1   @@Z/PX 211/DES PFT 234-2000

Central Office Ln entry assoc. with a key system showing ringing transferred to other than a specific Station Ln Number.
I1   @@A/TN 732 273-8640/PFT
I1   @@A/TN 732 273-8640/DES PFT

FID RULES/CONSTRAINTS:

  1. Data entry is required when ringing is transferred to a specific number.

SERVICE ORDER ACTIVITY NOTES:

  1. The FID PFT is associated with the line or trunk USOC is transferred to a specific station line number, the number must appear following the FID PFT.
  2. The FID DES should be associated with the transferred to USC, to cross reference the PFT arrangement.
  3. T, F and X order types are prohibited for Access Service application.
  4. X order codes are prohibited on Access Service orders.

REFERENCES:

  1. EWSD
    Siemens 0625-00790, Power Failure Transfer - Attendant; Siemens 0770-00010, PFT.

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - FL

Optional

Alphanumeric

4

8

Element: 1

Station Type Identifier

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

2

2

No

No

Code Set:

CodeMeaning
PX

Element Rules:

Required when Central Office Code does not appear.

Element: 2

Central Office Code

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

3

3

No

No

Reference:

See iconectiv LERG Routing Guide for complete list.

Element Rules:

Required when Station Type Identifier does not appear.

Element: 3

Station Line Number

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

4

No

No

Data Parameters:

1-9999

No.

Element Combination

Series

Separator

1.

1 SP 3

No

2.

2 - 3

No


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: S&E - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

O

P

P

Action Codes

I,E

I,E

O,D

O,D

I,O, C,T, D,E, M,X, R

I,O, C,T, D,E, M,X, R

I,O, C,T, R

-

-


CRIS

CABS

Data Retention

Yes

Yes

Printed on CSR

Yes

Yes




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.




iconectiv Confidential - Restricted Access

This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv.

Licensed Material - Property of iconectiv

Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv.