PGAD

PERMISSION GRANTED TO ADD

INDICATES:

The call letters and/or the name and location of customers who have permission to add to a "backbone" audio or television service of another customer at their own expense.

DATE:

6/9/2005

BILLING:

CRIS

APPLICATIONS:

General Purpose


SECTION - POSITION

EXAMPLES

S&E - FL

G1   CKL 4-50 ROCKEFELLER CTR,
     NEW YORK, NY/PGAD WLNA;
     PKSK NY/SN ABC NEWS

SERVICE ORDER ACTIVITY NOTES:

  1. This FID appears at the primary customer's service point Circuit Location (CKL) where the PGAD customer may order service; it does not authorize the provisioning of service.  A separate order must be issued to order the service components required to furnish service for the PGAD customer.

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - FL

Required

Alphanumeric

3

39

Element: 1

Customer Identification Text

Appearance

Mode

Min

Max

Series

Range

Required

Alphanumeric

3

30

Yes

No

Element: 2

COMMON LANGUAGE Geographical Code

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

3

4

No

No

Data Parameters:

A-Z

Symbols:

Space

Reference:

See BR 795-100-100 for more information on CLLI codes or go to www.commonlanguage.com/clli.

Element Rules:

Geographical Codes created after 11/8/95 must be 4 alpha characters.

Geographical Codes created prior to 11/8/95 were two to four alpha characters.  Two or 3 character codes were left justified and the unused (right most) positions were blank filled.  It is for the latter reason that use of the "space" text symbol is permitted and, as a result, the element mode must be shown as "AN".

The actual numeric character values of 0 through 9 are not, nor have they ever been, allowed within the Geographical Code.
Required as specified in BR 795-100-100.

Element: 3

COMMON LANGUAGE Geopolitical Code

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

2

2

No

No

Reference:

See BR 795-100-100 for more information on CLLI codes or go to www.commonlanguage.com/clli.

Element Rules:

Required when call letters are not entered as Element 1.
Required as specified in BR 795-100-100.

No.

Element Combination

Series

Separator

1.

1

Yes

, SP

2.

1 ; SP 2 SP 3

Yes

, SP


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: S&E - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

O

P

P

Action Codes

I,E

I,E

O,D

O,D

I,O, C,T, M,X, D,E, R

I,O, C,T, M,X, D,E, R

C,T, R

-

-


CRIS

CABS

Data Retention

Yes

No

Printed on CSR

Yes

No




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.




iconectiv Confidential - Restricted Access

This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv.

Licensed Material - Property of iconectiv

Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv.