PHML

MULTILINE HUNT IDENTITY OF A PRIMARY NUMBER

INDICATES:

The multiline hunt group and terminal numbers of the primary call appearance of a Integrated Services Digital Network (ISDN) terminal on which a secondary directory number appears.

DATE:

12/8/2005

BILLING:

CRIS

APPLICATIONS:

5ESS, ISDN BRI


SECTION - POSITION

EXAMPLES

S&E - FL

G1   PN 732 555-1200/DSNA 10.IBZX.123456..NJ
I1   @@A/TER 2/HML 5/TLI 732 555-1200
     /CAPP CA.1, NBR.1
G2   PHML 5, 2
I1   @@Q/TN 732 555-1234/CAPP CA.2, NBR.1

ASGM - FL

G1   PN 732 555-1200/DSNA 10.IBZX.123456..NJ
G2   TN 732 555-1234/KEY 2/PHML 5, 2
IOE  NR/OER 027-109-25/EXK 732 555

FID RULES/CONSTRAINTS:

  1. FID is prohibited on the ISDN logical terminal assignable line USOC logical line that is associated with call appearance number 1.
  2. The PHML FID is required on the ISDN secondary appearance USOC logical line when:

    a.  the primary call appearance is in Munting - Multiline Group Number (HML) / Terminal Number - Multiline Group (TER) format, and

    b.  the primary call appearance has no associated Telephone Number (TN), and

    c.  the Primary Number (PN) FID data and Terminal Line Identifier (TLI) data are identical
  3. Section:  ASGM      Position:  FL
    This FID is entered on the Central Office Facility subset.

REFERENCES:

  1. Lucent Technologies, 235-118-257, Views 23.20 and 23.21, Keyword MLHG

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - FL

Required

Numeric

4

10

Element: 1

Hunting Multiline Group Number

Appearance

Mode

Min

Max

Series

Range

Required

Numeric

1

4

No

No

Data Parameters:

1-20005ESS (5E14 and Prior)
1-81915ESS (5E15)

Element: 2

Hunting Terminal Number

Appearance

Mode

Min

Max

Series

Range

Required

Numeric

1

4

No

No

Data Parameters:

1-20475ESS
1-2015Packet - 5ESS

No.

Element Combination

Series

Separator

1.

1 , SP 2

No


SECTION - POSITION

ASGM - FL

Please refer to S&E - FL for all data requirements.


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: S&E - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

O

P

P

Action Codes

I,E

I,E

O,D

O,D

I,O, C,T, M,X, D,E, R

I,O, C,T, M,X, D,E, R

C,T, R

-

-


CRIS

CABS

Data Retention

Yes

No

Printed on CSR

Yes

No

Order Section - Position: ASGM - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

P

O

P

P

Action Codes

I

I

O

O

I,O

-

I,O

-

-


CRIS

CABS

Data Retention

No

No

Printed on CSR

No

No




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.




iconectiv Confidential - Restricted Access

This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv.

Licensed Material - Property of iconectiv

Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv.