PILN

PILOT DIRECTORY NUMBER FOR SIMULTANEOUS RINGING

INDICATES:

The pilot directory number for a group of numbers that are allowed to be alerted by simultaneous ringing.

DATE:

6/12/2003

BILLING:

CRIS and CABS

APPLICATIONS:

DMS-100


SECTION - POSITION

EXAMPLES

S&E - FL

I1   @@E/TN 732 555-1234/PILN
     /LASS SIMRING STAT.ACTIVE,
     SIMRPIN.22344

I1   @@E/TN 732 555-1234/PILN
     /LASS SIMRING STAT.ACTIVE,
     SIMRPIN.22344/CTX A12F:3
     /CAT 1

FID RULES/CONSTRAINTS:

  1. If or when any changes are made to the S&E section of the service order (changes or corrections to service) the logical line that the PILN FID appears on must be recapped.
  2. T, F, and X order types prohibited for Access Service application.
  3. X action code prohibited on Access Service orders.

SERVICE ORDER ACTIVITY NOTES:

  1. The Simultaneous Ringing feature in the DMS-100 switch (provisioned via a physical pilot DN) allows a predefined group of up to 5 Directory Numbers (DNs) to be alerted simultaneously when a specific member of this group, referred to as the pilot DN, is called.  The pilot DN is equal to the main TN.
  2. The Simultaneous Ringing Virtual DN feature in the DMS-100 switch allows a predefined group of up to 4 DNs to be alerted simultaneously when a specific member of this group, referred to as the pilot DN, is called.  The pilot DN appears in software only with no physical line appearance or hardware associated with it.  It requires a separate feature USOC coded as TN only in the SOAC USOC tables, in order to prevent the assignment of central office line equipment.
  3. The Simultaneous Ringing Virtual DN feature requires the presence of the CTX, CAT and LASS FIDs on the same logical line.

REFERENCES:

  1. DMS-100 NA010
    NORTEL Preliminary Documentation, Feature AJ4934, Option SIMRING.
  2. DMS-100 NA017
    NORTEL Preliminary Documentation, Feature A59030419, Option SIMRING VIRTUAL DN.

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - FL

Prohibited

0

0


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: S&E - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

O

P

P

Action Codes

I,E

I,E

O,D

O,D

I,O, C,T, D,E, M,X, R

I,O, C,T, D,E, M,X, R

I,O, C,T, R

-

-

Other FIDs Required Logical Line

LASS

LASS

LASS

LASS

LASS

LASS

LASS

-

-


CRIS

CABS

Data Retention

Yes

Yes

Printed on CSR

Yes

Yes




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.




iconectiv Confidential - Restricted Access

This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv.

Licensed Material - Property of iconectiv

Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv.