PMC

PRIMARY MAINTENANCE CONTACT

INDICATES:

The name and telephone number of the primary person to be contacted for maintenance subsequent to the installation of the service.

DATE:

10/31/2014

BILLING:

CRIS and CABS

APPLICATIONS:

Public Packet Switched Network (PPSN)


SECTION - POSITION

EXAMPLES

CTL - LH

PMC  MARY BROWN, 732 555-4567 EX 12345

CTL - FL

     /PMC MARY BROWN, 732 555-1234

FID RULES/CONSTRAINTS:

  1. T, F, and X order types prohibited for Access Service application.

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

CTL - LH

Required

Alphanumeric

17

53

Element: 1

Primary Maintenance Contact Name

Appearance

Mode

Min

Max

Series

Range

Required

Alphanumeric

3

30

No

No

Symbols:

Apostrophe, Hyphen, Period, Space

Element: 2

Numbering Plan Area Code

Appearance

Mode

Min

Max

Series

Range

Required

Numeric

3

3

No

No

Reference:

See iconectiv LERG Routing Guide for complete list.

Element: 3

Central Office Code

Appearance

Mode

Min

Max

Series

Range

Required

Numeric

3

3

No

No

Reference:

See iconectiv LERG Routing Guide for complete list.

Element: 4

Line Number

Appearance

Mode

Min

Max

Series

Range

Required

Numeric

4

4

No

No

Data Parameters:

0000-9999

Element: 5

Extension Attribute Name

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

2

2

No

No

Code Set:

CodeMeaning
EXExtension

Element: 6

Extension Number Attribute Value

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

5

No

No

No.

Element Combination

Series

Separator

1.

1 , SP 2 SP 3 - 4

No

2.

1 , SP 2 SP 3 - 4 SP 5 SP 6

No


SECTION - POSITION

CTL - FL

Please refer to CTL - LH for all data requirements.


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: CTL - LH

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

P

O

P

P

Action Codes

-

-

-

-

-

-

-

-

-


CRIS

CABS

Data Retention

No

No

Printed on CSR

No

No

Order Section - Position: CTL - FL

 

Please refer to CTL - LH for Order Type, Action Code, and FID relationships.




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.




iconectiv Confidential - Restricted Access

This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv.

Licensed Material - Property of iconectiv

Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv.