POE |
PACKET ORIGINATING EQUIPMENT |
INDICATES: |
The physical termination assignment for packet service. |
DATE: |
11/17/2011 |
BILLING: |
CRIS and CABS |
APPLICATIONS: |
5ESS, DMS-100, FETEX-150, Frame Relay, ISDN BRI, Local Area Network (LAN), Public Packet Switched Network (PPSN) |
SECTION - POSITION |
EXAMPLES |
S&E - FL |
|
AT&T Technologies DSI |
|
ASGM - LH |
|
AT&T Technologies DSI |
FID RULES/CONSTRAINTS: |
|
SECTION - POSITION |
APPEARANCE |
MODE |
MIN |
MAX |
S&E - FL |
Required |
Alphanumeric |
5 |
29 |
Element: 1 |
COMMON LANGUAGE Geographical Code |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphanumeric |
4 |
4 |
No |
No |
Data Parameters: |
||
|
Symbols: |
Space |
Reference: |
See BR 795-100-100 for more information on CLLI codes or go to www.commonlanguage.com/clli. |
Element Rules: |
||
|
Element: 2 |
COMMON LANGUAGE Geopolitical Code |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphabetic |
2 |
2 |
No |
No |
Reference: |
See BR 795-100-100 for more information on CLLI codes or go to www.commonlanguage.com/clli. |
Element Rules: |
Required as specified in BR 795-100-100. |
Element: 3 |
CLLI Network Site Code |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphabetic or Numeric |
2 |
2 |
No |
No |
Reference: |
See BR 795-100-100 for more information on CLLI codes or go to www.commonlanguage.com/clli. |
Element Rules: |
Required as specified in BR 795-100-100. |
Element: 4 |
CLLI Network Entity Code |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphanumeric |
3 |
3 |
No |
No |
Reference: |
See BR 795-100-100 for more information on CLLI codes or go to www.commonlanguage.com/clli. |
Element Rules: |
Required as specified in BR 795-100-100. |
Element: 5 |
Node |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
2 |
2 |
No |
No |
Data Parameters: |
||
|
Element: 6 |
AT&T - DSI/Frame Function Code |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphabetic |
4 |
4 |
No |
No |
Code Set: |
||||
|
Element: 7 |
AT&T - DSI/Bay Number |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
2 |
2 |
No |
No |
Data Parameters: |
||
|
Element: 8 |
AT&T - DSI/Unit Number |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
1 |
1 |
No |
No |
Data Parameters: |
||
|
Element: 9 |
AT&T - DSI/Card Position |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
2 |
2 |
No |
No |
Data Parameters: |
||
|
Element: 10 |
AT&T - DSI/Port |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
1 |
1 |
No |
No |
Data Parameters: |
||
|
Element: 11 |
AT&T - PSS/Frame Function Code |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphabetic |
3 |
3 |
No |
No |
Code Set: |
||||
|
Element: 12 |
AT&T - PSS/Bay Number |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
1 |
1 |
No |
No |
Data Parameters: |
||
|
Element: 13 |
AT&T - PSS/Facility Interface Processor |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
2 |
2 |
No |
No |
Data Parameters: |
||
|
Element: 14 |
AT&T - PSS/Facility Interface Type |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphabetic |
1 |
1 |
No |
No |
Code Set: |
||||
|
Element: 15 |
AT&T - PSS/Port |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
1 |
1 |
No |
No |
Data Parameters: |
||
|
Element: 16 |
Entity Group (5ESS ISDN) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphabetic or Numeric |
1 |
1 |
No |
No |
Data Parameters: |
||||
|
Element: 17 |
Packet Switch Unit (5ESS ISDN) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
3 |
3 |
No |
No |
Data Parameters: |
||
|
Element: 18 |
Shelf (5ESS ISDN) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
1 |
1 |
No |
No |
Data Parameters: |
||
|
Element: 19 |
Packet Handler (5ESS ISDN) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
2 |
2 |
No |
No |
Data Parameters: |
||
|
Element: 20 |
Packet Handler Port (5ESS ISDN) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
3 |
3 |
No |
No |
Data Parameters: |
||
|
Element: 21 |
Northern Telcom SL-10 - Frame Function Code |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphabetic |
4 |
4 |
No |
No |
Code Set: |
||||||
|
Element: 22 |
Northern Telcom SL-10 - Bay Number |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
1 |
1 |
No |
No |
Data Parameters: |
||
|
Element: 23 |
Northern Telcom SL-10 - Shelf Number |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphanumeric |
2 |
2 |
No |
No |
Data Parameters: |
||||
|
Element: 24 |
Northern Telcom SL-10 - Shelf Type |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphabetic |
2 |
2 |
No |
No |
Code Set: |
||||||||
|
Element: 25 |
Northern Telcom SL-10 - Card Position |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
2 |
2 |
No |
No |
Data Parameters: |
||
|
Element: 26 |
Northern Telcom SL-10 - Port Number |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
1 |
1 |
No |
No |
Data Parameters: |
||
|
Element: 27 |
DataBit-ANP-2520 - Lineup |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
1 |
5 |
No |
No |
Data Parameters: |
||
|
Element: 28 |
DataBit-ANP-2520 - Bay |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
1 |
2 |
No |
No |
Data Parameters: |
||
|
Element: 29 |
DataBit-ANP-2520 - Bay Shelf |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphanumeric |
1 |
2 |
No |
No |
Data Parameters: |
||||
|
Element: 30 |
DataBit-ANP-2520 - Card Position |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
1 |
2 |
No |
No |
Data Parameters: |
||
|
Element Rules: |
Card positions 6-8 are for internodal trunk only. |
Element: 31 |
DataBit-ANP-2520 - Port |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
1 |
1 |
No |
No |
Data Parameters: |
||
|
Element: 32 |
Siemens -EDX-P Packet Switch Lineup |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
1 |
5 |
No |
No |
Data Parameters: |
||
|
Element: 33 |
Siemens -EDX-P Packet Switch Bay |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
1 |
2 |
No |
No |
Data Parameters: |
||
|
Element: 34 |
Siemens -EDX-P Packet Switch Terminator Group Number |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
1 |
2 |
No |
No |
Data Parameters: |
||
|
Element: 35 |
Siemens -EDX-P Packet Switch Card Position |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
1 |
2 |
No |
No |
Data Parameters: |
||
|
Element: 36 |
Siemens -EDX-P Packet Switch Port |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
1 |
1 |
No |
No |
Data Parameters: |
||
|
Element: 37 |
Node (DATAKIT) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphanumeric |
1 |
8 |
No |
No |
Data Parameters: |
||
|
Element: 38 |
Module (DATAKIT) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
3 |
3 |
No |
No |
Data Parameters: |
||
|
Element: 39 |
Port or Channel Number (DATAKIT) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
2 |
2 |
No |
No |
Data Parameters: |
||
|
Element Rules: |
Prohibited for trunk terminations. |
Element: 40 |
Frame Number (FETEX-150) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
4 |
4 |
No |
No |
Data Parameters: |
||
|
Element: 41 |
Shelf Number (FETEX-150) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
1 |
1 |
No |
No |
Data Parameters: |
||
|
Element: 42 |
Digital Terminal Number (FETEX-150) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
2 |
2 |
No |
No |
Data Parameters: |
||
|
Element: 43 |
Channel Number (FETEX-150) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
2 |
2 |
No |
No |
Data Parameters: |
||
|
Element: 44 |
Shelf (DATAKIT II VCS) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
1 |
1 |
No |
No |
Data Parameters: |
||
|
Element: 45 |
Slot (DATAKIT II VCS) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
3 |
3 |
No |
No |
Data Parameters: |
||
|
Element: 46 |
Port (DATAKIT II VCS) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
2 |
2 |
No |
No |
Data Parameters: |
||
|
Element: 47 |
Node (AT&T BNS 2000 - Frame Relay) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
1 |
1 |
No |
No |
Data Parameters: |
||
|
Element: 48 |
Shelf (AT&T BNS 2000 - Frame Relay) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
1 |
3 |
No |
No |
Data Parameters: |
||
|
Element: 49 |
Slot (AT&T BNS 2000 - Frame Relay) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
1 |
2 |
No |
No |
Data Parameters: |
||
|
Element: 50 |
Node (AT&T DATAKIT - Frame Relay) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
1 |
1 |
No |
No |
Data Parameters: |
||
|
Element: 51 |
Shelf (AT&T DATAKIT - Frame Relay) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
1 |
3 |
No |
No |
Data Parameters: |
||
|
Element: 52 |
Slot (AT&T DATAKIT - Frame Relay) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
1 |
2 |
No |
No |
Data Parameters: |
||
|
Element: 53 |
Node (Cascade STDX 6000 - Frame Relay) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
1 |
1 |
No |
No |
Data Parameters: |
||
|
Element: 54 |
Shelf (Cascade STDX 6000 - Frame Relay) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
1 |
1 |
No |
No |
Data Parameters: |
||
|
Element: 55 |
Slot (Cascade STDX 6000 - Frame Relay) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
1 |
1 |
No |
No |
Data Parameters: |
||
|
Element: 56 |
Logical Port (Cascade STDX 6000 - Frame Relay) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
1 |
2 |
No |
No |
Data Parameters: |
||
|
Element: 57 |
Node (Cascade B-STDX 9000 - Frame Relay) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
1 |
1 |
No |
No |
Data Parameters: |
||
|
Element: 58 |
Shelf (Cascade B-STDX 9000 - Frame Relay) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
1 |
2 |
No |
No |
Data Parameters: |
||
|
Element: 59 |
Slot (Cascade B-STDX 9000 - Frame Relay) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
1 |
1 |
No |
No |
Data Parameters: |
||
|
Element: 60 |
Logical Port (Cascade B-STDX 9000 - Frame Relay) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
1 |
2 |
No |
No |
Data Parameters: |
||
|
No. |
Element Combination |
Series |
Separator |
1. |
1 2 3 4 - 6 - 7 - 8 - 9 - 10 |
No |
|
2. |
1 2 3 4 - 11 - 12 - 13 - 14 - 15 |
No |
|
3. |
1 2 3 4 - 21 - 22 - 23 - 24 - 25 - 26 |
No |
|
4. |
1 2 3 4 - 27 - 28 - 29 - 30 - 31 |
No |
|
5. |
1 2 3 4 - 32 - 33 - 34 - 35 - 36 |
No |
|
6. |
1 2 3 4 - 37 - 38 |
No |
|
7. |
1 2 3 4 - 37 - 38 - 39 |
No |
|
8. |
1 2 3 4 - 44 - 45 - 46 |
No |
|
9. |
1 2 3 4 - 47 - 48 - 49 |
No |
|
10. |
1 2 3 4 - 50 - 51 - 52 |
No |
|
11. |
1 2 3 4 - 53 - 54 - 55 - 56 |
No |
|
12. |
1 2 3 4 - 57 - 58 - 59 - 60 |
No |
|
13. |
1 2 3 - 44 - 45 - 46 |
No |
|
14. |
5 - 6 - 7 - 8 - 9 - 10 |
No |
|
15. |
5 - 11 - 12 - 13 - 14 - 15 |
No |
|
16. |
5 - 21 - 22 - 23 - 24 - 25 - 26 |
No |
|
17. |
5 - 27 - 28 - 29 - 30 - 31 |
No |
|
18. |
5 - 32 - 33 - 34 - 35 - 36 |
No |
|
19. |
6 - 7 - 8 - 9 - 10 |
No |
|
20. |
11 - 12 - 13 - 14 - 15 |
No |
|
21. |
16 17 - 18 - 19 - 20 |
No |
|
22. |
21 - 22 - 23 - 24 - 25 - 26 |
No |
|
23. |
27 - 28 - 29 - 30 - 31 |
No |
|
24. |
32 - 33 - 34 - 35 - 36 |
No |
|
25. |
37 - 38 |
No |
|
26. |
37 - 38 - 39 |
No |
|
27. |
40 - 41 - 42 - 43 |
No |
|
28. |
44 - 45 - 46 |
No |
SECTION - POSITION |
APPEARANCE |
MODE |
MIN |
MAX |
ASGM - LH |
Required |
Alphanumeric |
2 |
29 |
Element: 1 |
COMMON LANGUAGE Geographical Code |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphanumeric |
4 |
4 |
No |
No |
Data Parameters: |
||
|
Symbols: |
Space |
Reference: |
See BR 795-100-100 for more information on CLLI codes or go to www.commonlanguage.com/clli. |
Element Rules: |
||
|
Element: 2 |
COMMON LANGUAGE Geopolitical Code |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphabetic |
2 |
2 |
No |
No |
Reference: |
See BR 795-100-100 for more information on CLLI codes or go to www.commonlanguage.com/clli. |
Element Rules: |
Required as specified in BR 795-100-100. |
Element: 3 |
CLLI Network Site Code |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphabetic or Numeric |
2 |
2 |
No |
No |
Reference: |
See BR 795-100-100 for more information on CLLI codes or go to www.commonlanguage.com/clli. |
Element Rules: |
Required as specified in BR 795-100-100. |
Element: 4 |
CLLI Network Entity Code |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphanumeric |
3 |
3 |
No |
No |
Reference: |
See BR 795-100-100 for more information on CLLI codes or go to www.commonlanguage.com/clli. |
Element Rules: |
Required as specified in BR 795-100-100. |
Element: 5 |
Node |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
2 |
2 |
No |
No |
Data Parameters: |
||
|
Element: 6 |
AT&T - DSI/Frame Function Code |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphabetic |
4 |
4 |
No |
No |
Code Set: |
||||
|
Element: 7 |
AT&T - DSI/Bay Number |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
2 |
2 |
No |
No |
Data Parameters: |
||
|
Element: 8 |
AT&T - DSI/Unit Number |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
1 |
1 |
No |
No |
Data Parameters: |
||
|
Element: 9 |
AT&T - DSI/Card Position |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
2 |
2 |
No |
No |
Data Parameters: |
||
|
Element: 10 |
AT&T - DSI/Port |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
1 |
1 |
No |
No |
Data Parameters: |
||
|
Element: 11 |
AT&T - PSS/Frame Function Code |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphabetic |
3 |
3 |
No |
No |
Code Set: |
||||
|
Element: 12 |
AT&T - PSS/Bay Number |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
1 |
1 |
No |
No |
Data Parameters: |
||
|
Element: 13 |
AT&T - PSS/Facility Interface Processor |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
2 |
2 |
No |
No |
Data Parameters: |
||
|
Element: 14 |
AT&T - PSS/Facility Interface Type |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphabetic |
1 |
1 |
No |
No |
Code Set: |
||||
|
Element: 15 |
AT&T - PSS/Port |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
1 |
1 |
No |
No |
Data Parameters: |
||
|
Element: 16 |
Entity Group (5ESS ISDN) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphabetic or Numeric |
1 |
1 |
No |
No |
Data Parameters: |
||||
|
Element: 17 |
Packet Switch Unit (5ESS ISDN) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
3 |
3 |
No |
No |
Data Parameters: |
||
|
Element: 18 |
Shelf (5ESS ISDN) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
1 |
1 |
No |
No |
Data Parameters: |
||
|
Element: 19 |
Packet Handler (5ESS ISDN) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
2 |
2 |
No |
No |
Data Parameters: |
||
|
Element: 20 |
Packet Handler Port (5ESS ISDN) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
3 |
3 |
No |
No |
Data Parameters: |
||
|
Element: 21 |
Northern Telcom SL-10 - Frame Function Code |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphabetic |
4 |
4 |
No |
No |
Code Set: |
||||||
|
Element: 22 |
Northern Telcom SL-10 - Bay Number |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
1 |
1 |
No |
No |
Data Parameters: |
||
|
Element: 23 |
Northern Telcom SL-10 - Shelf Number |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphanumeric |
2 |
2 |
No |
No |
Data Parameters: |
||||
|
Element: 24 |
Northern Telcom SL-10 - Shelf Type |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphabetic |
2 |
2 |
No |
No |
Code Set: |
||||||||
|
Element: 25 |
Northern Telcom SL-10 - Card Position |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
2 |
2 |
No |
No |
Data Parameters: |
||
|
Element: 26 |
Northern Telcom SL-10 - Port Number |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
1 |
1 |
No |
No |
Data Parameters: |
||
|
Element: 27 |
DataBit-ANP-2520 - Lineup |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
1 |
5 |
No |
No |
Data Parameters: |
||
|
Element: 28 |
DataBit-ANP-2520 - Bay |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
1 |
2 |
No |
No |
Data Parameters: |
||
|
Element: 29 |
DataBit-ANP-2520 - Bay Shelf |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphanumeric |
1 |
2 |
No |
No |
Data Parameters: |
||||
|
Element: 30 |
DataBit-ANP-2520 - Card Position |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
1 |
2 |
No |
No |
Data Parameters: |
||
|
Element Rules: |
Card positions 6-8 are for internodal trunk only. |
Element: 31 |
DataBit-ANP-2520 - Port |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
1 |
1 |
No |
No |
Data Parameters: |
||
|
Element: 32 |
Siemens -EDX-P Packet Switch Lineup |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
1 |
5 |
No |
No |
Data Parameters: |
||
|
Element: 33 |
Siemens -EDX-P Packet Switch Bay |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
1 |
2 |
No |
No |
Data Parameters: |
||
|
Element: 34 |
Siemens -EDX-P Packet Switch Terminator Group Number |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
1 |
2 |
No |
No |
Data Parameters: |
||
|
Element: 35 |
Siemens -EDX-P Packet Switch Card Position |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
1 |
2 |
No |
No |
Data Parameters: |
||
|
Element: 36 |
Siemens -EDX-P Packet Switch Port |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
1 |
1 |
No |
No |
Data Parameters: |
||
|
Element: 37 |
Node (DATAKIT) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphanumeric |
1 |
8 |
No |
No |
Data Parameters: |
||
|
Element: 38 |
Module (DATAKIT) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
3 |
3 |
No |
No |
Data Parameters: |
||
|
Element: 39 |
Port or Channel Number (DATAKIT) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
2 |
2 |
No |
No |
Data Parameters: |
||
|
Element Rules: |
Prohibited for trunk terminations. |
Element: 40 |
Frame Number (FETEX-150) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
4 |
4 |
No |
No |
Data Parameters: |
||
|
Element: 41 |
Shelf Number (FETEX-150) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
1 |
1 |
No |
No |
Data Parameters: |
||
|
Element: 42 |
Digital Terminal Number (FETEX-150) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
2 |
2 |
No |
No |
Data Parameters: |
||
|
Element: 43 |
Channel Number (FETEX-150) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
2 |
2 |
No |
No |
Data Parameters: |
||
|
Element: 44 |
Shelf (DATAKIT II VCS) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
1 |
1 |
No |
No |
Data Parameters: |
||
|
Element: 45 |
Slot (DATAKIT II VCS) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
3 |
3 |
No |
No |
Data Parameters: |
||
|
Element: 46 |
Port (DATAKIT II VCS) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
2 |
2 |
No |
No |
Data Parameters: |
||
|
Element: 47 |
Node (AT&T BNS 2000 - Frame Relay) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
1 |
1 |
No |
No |
Data Parameters: |
||
|
Element: 48 |
Shelf (AT&T BNS 2000 - Frame Relay) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
1 |
3 |
No |
No |
Data Parameters: |
||
|
Element: 49 |
Slot (AT&T BNS 2000 - Frame Relay) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
1 |
2 |
No |
No |
Data Parameters: |
||
|
Element: 50 |
Node (AT&T DATAKIT - Frame Relay) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
1 |
1 |
No |
No |
Data Parameters: |
||
|
Element: 51 |
Shelf (AT&T DATAKIT - Frame Relay) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
1 |
3 |
No |
No |
Data Parameters: |
||
|
Element: 52 |
Slot (AT&T DATAKIT - Frame Relay) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
1 |
2 |
No |
No |
Data Parameters: |
||
|
Element: 53 |
Node (Cascade STDX 6000 - Frame Relay) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
1 |
1 |
No |
No |
Data Parameters: |
||
|
Element: 54 |
Shelf (Cascade STDX 6000 - Frame Relay) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
1 |
1 |
No |
No |
Data Parameters: |
||
|
Element: 55 |
Slot (Cascade STDX 6000 - Frame Relay) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
1 |
1 |
No |
No |
Data Parameters: |
||
|
Element: 56 |
Logical Port (Cascade STDX 6000 - Frame Relay) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
1 |
2 |
No |
No |
Data Parameters: |
||
|
Element: 57 |
Node (Cascade B-STDX 9000 - Frame Relay) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
1 |
1 |
No |
No |
Data Parameters: |
||
|
Element: 58 |
Shelf (Cascade B-STDX 9000 - Frame Relay) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
1 |
2 |
No |
No |
Data Parameters: |
||
|
Element: 59 |
Slot (Cascade B-STDX 9000 - Frame Relay) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
1 |
1 |
No |
No |
Data Parameters: |
||
|
Element: 60 |
Logical Port (Cascade B-STDX 9000 - Frame Relay) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
1 |
2 |
No |
No |
Data Parameters: |
||
|
Element: 61 |
Data Entry Requirement Indicator |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphabetic |
2 |
2 |
No |
No |
Code Set: |
||||
|
No. |
Element Combination |
Series |
Separator |
1. |
1 2 3 4 - 6 - 7 - 8 - 9 - 10 |
No |
|
2. |
1 2 3 4 - 11 - 12 - 13 - 14 - 15 |
No |
|
3. |
1 2 3 4 - 21 - 22 - 23 - 24 - 25 - 26 |
No |
|
4. |
1 2 3 4 - 27 - 28 - 29 - 30 - 31 |
No |
|
5. |
1 2 3 4 - 32 - 33 - 34 - 35 - 36 |
No |
|
6. |
1 2 3 4 - 37 - 38 |
No |
|
7. |
1 2 3 4 - 37 - 38 - 39 |
No |
|
8. |
1 2 3 4 - 44 - 45 - 46 |
No |
|
9. |
1 2 3 4 - 47 - 48 - 49 |
No |
|
10. |
1 2 3 4 - 50 - 51 - 52 |
No |
|
11. |
1 2 3 4 - 53 - 54 - 55 - 56 |
No |
|
12. |
1 2 3 4 - 57 - 58 - 59 - 60 |
No |
|
13. |
1 2 3 - 44 - 45 - 46 |
No |
|
14. |
5 - 6 - 7 - 8 - 9 - 10 |
No |
|
15. |
5 - 11 - 12 - 13 - 14 - 15 |
No |
|
16. |
5 - 21 - 22 - 23 - 24 - 25 - 26 |
No |
|
17. |
5 - 27 - 28 - 29 - 30 - 31 |
No |
|
18. |
5 - 32 - 33 - 34 - 35 - 36 |
No |
|
19. |
6 - 7 - 8 - 9 - 10 |
No |
|
20. |
11 - 12 - 13 - 14 - 15 |
No |
|
21. |
16 17 - 18 - 19 - 20 |
No |
|
22. |
21 - 22 - 23 - 24 - 25 - 26 |
No |
|
23. |
27 - 28 - 29 - 30 - 31 |
No |
|
24. |
32 - 33 - 34 - 35 - 36 |
No |
|
25. |
37 - 38 |
No |
|
26. |
37 - 38 - 39 |
No |
|
27. |
40 - 41 - 42 - 43 |
No |
|
28. |
44 - 45 - 46 |
No |
|
29. |
61 |
No |
ORDER TYPE/ACTION CODE/FID RELATIONSHIPS |
Order Section - Position: S&E - FL
|
Order Type |
N |
T |
F |
D |
C |
R |
X |
P |
A |
Presence |
O |
O |
O |
O |
O |
O |
O |
P |
P |
Action Codes |
I,E |
I,E |
O,D |
O,D |
I,O, C,T, D,E, X,R, M |
I,O, C,T, D,E, X,R, M |
I,O, C,T, R |
- |
- |
Other FIDs Prohibited Different Section |
LPRT |
LPRT |
LPRT |
LPRT |
LPRT |
- |
LPRT |
- |
- |
CRIS |
CABS |
|
Data Retention |
No |
No |
Printed on CSR |
No |
No |
Order Section - Position: ASGM - LH
|
Order Type |
N |
T |
F |
D |
C |
R |
X |
P |
A |
Presence |
O |
O |
O |
O |
O |
P |
O |
P |
P |
Action Codes |
I |
I |
O |
O |
I,O |
- |
I,O |
- |
- |
Other FIDs Prohibited Logical Line |
LPRT |
LPRT |
LPRT |
LPRT |
LPRT |
- |
LPRT |
- |
- |
CRIS |
CABS |
|
Data Retention |
No |
No |
Printed on CSR |
No |
No |
Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure. |
iconectiv Confidential - Restricted Access This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv. |