POER

PACKET ORIGINATING EQUIPMENT REFERENCE

INDICATES:

A reference to an ISDN pipe's central office packet originating equipment.

DATE:

11/17/2011

BILLING:

CRIS and CABS

APPLICATIONS:

5ESS, ISDN BRI


SECTION - POSITION

EXAMPLES

ASGM - FL

5ESS ISDN
IPOE NR/POER 9001-4-10-014

Northern Telecom SL-10
IPOE NR/POER PSLC-4-1B-LC-25-1

FID RULES/CONSTRAINTS:

  1. T, F and X order types prohibited for Access Service application.
  2. This FID is entered in the Central Office Facilities Subset.

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

ASGM - FL

Required

Alphanumeric

13

29

Element: 1

COMMON LANGUAGE Geographical Code

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

4

4

No

No

Data Parameters:

A-Z

Symbols:

Space

Reference:

See BR 795-100-100 for more information on CLLI codes or go to www.commonlanguage.com/clli.

Element Rules:

Geographical Codes created after 11/08/95 must be 4 alpha characters.

Geographical Codes created prior to 11/8/95 were two to four alpha characters.  Two or 3 character codes were left justified and the unsued (right most) positions were blank filled.  It is for the latter reason that use of the "space" text symbol is permitted and, as a result, the element mode must be shown as "AN".

The actual numeric character values of 0 through 9 are not, nor have they ever been, allowed within the Geographical Code.
Required as specified in BR 795-100-100.

Element: 2

COMMON LANGUAGE Geopolitical Code

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

2

2

No

No

Reference:

See BR 795-100-100 for more information on CLLI codes or go to www.commonlanguage.com/clli.

Element Rules:

Required as specified in BR 795-100-100.

Element: 3

CLLI Network Site Code

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic or Numeric

2

2

No

No

Reference:

See BR 795-100-100 for more information on CLLI codes or go to www.commonlanguage.com/clli.

Element Rules:

Required as specified in BR 795-100-100.

Element: 4

CLLI Network Entity Code

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

3

3

No

No

Reference:

See BR 795-100-100 for more information on CLLI codes or go to www.commonlanguage.com/clli.

Element Rules:

Required as specified in BR 795-100-100.

Element: 5

Entity Group (5ESS ISDN)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic or Numeric

1

1

No

No

Data Parameters:

A-Z
0-9

Element: 6

Packet Switch Unit (5ESS ISDN)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

3

3

No

No

Data Parameters:

001-192

Element: 7

Shelf (5ESS ISDN)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

1

No

No

Data Parameters:

0-4

Element: 8

Packet Handler (5ESS ISDN)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

2

2

No

No

Data Parameters:

00-15

Element: 9

Packet Handler Port (5ESS ISDN)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

3

3

No

No

Data Parameters:

000-127

Element: 10

Northern Telecom SL-10 - Frame Function Code

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

4

4

No

No

Code Set:

CodeMeaning
PSLC
PSCC

Element: 11

Northern Telecom SL-10 - Bay Number

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

1

No

No

Data Parameters:

0-7

Element: 12

Northern Telecom SL-10 - Shelf Number

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

2

2

No

No

Data Parameters:

1A-4A
1B-4B

Element: 13

Northern Telecom SL-10 - Shelf Type

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

2

2

No

No

Code Set:

CodeMeaning
LCLine Card
LPLine Processor
TPTrunk Processor

Element: 14

Northern Telecom SL-10 - Card Position

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

2

2

No

No

Data Parameters:

00-99

Element: 15

Northern Telecom SL-10 - Port Number

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

1

No

No

Data Parameters:

0-1

No.

Element Combination

Series

Separator

1.

1  2  3  4 - 5  6 - 7 - 8 - 9

No

2.

1  2  3  4 - 10 - 11 - 12 - 13 - 14 - 15

No

3.

5  6 - 7 - 8 - 9

No

4.

10 - 11 - 12 - 13 - 14 - 15

No


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: ASGM - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

P

O

P

P

Action Codes

I

I

O

O

I,O

-

I,O

-

-

Other FIDs Required Logical Line

POE

POE

POE

POE

POE

-

POE

-

-


CRIS

CABS

Data Retention

No

No

Printed on CSR

No

No




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.




iconectiv Confidential - Restricted Access

This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv.

Licensed Material - Property of iconectiv

Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv.