PSM

CLCI PREFIX, SERVICE CODE AND MODIFIER

INDICATES:

The Prefix, Service Code and Modifier for a special services circuit.

DATE:

3/18/2004

BILLING:

CRIS and CABS

APPLICATIONS:

General Purpose


SECTION - POSITION

EXAMPLES

S&E - FL

Before Assembly of the CLCI
I1   @@A/PSM 12.FXNT/SCS FXSTS
     /TN 213 221-4645

After Assembly of the CLCI
I1   @@A/PSM 12.FXNT/SCS FXSTS
     /TN 213 221-4645/SGN A
     /CLT 12.FXNT.213.221.4645..A

ASGM - FL

G2   CLT 12.FXNT.212.221.4654
     /PSM 12.FXNT/TN 212 221-4645
IDE  12-101-202

FID RULES/CONSTRAINTS:

  1. When the FID CLT appears on the service order, PSM is optional.  When the FID CLT does not appear on the service order, PSM is required.
  2. Section  ASGM  Position  FL:
    This FID is entered in the Miscellaneous Subset, Central Office Facilities Subset and Outside Plant Facilities Subset.
  3. On Access Service orders, the FID PSM can appear on a C and T Action Coded logical line but C and T Action Codes cannot be used to change the data following the PSM FID.
  4. T, F and X order types are prohibited for Access Service application.
  5. X action codes are prohibited on Access Service orders.

SERVICE ORDER ACTIVITY NOTES:

  1. The presence of the PSM FID:  

    -  is required when a full CLCI Telephone Number format is to be assembled for    the circuit behind the FID CLT.

    -  impses a requirement for the assembly of a CLCI Telephone Number Format    for the circuit.

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - FL

Required

Alphanumeric

5

7

Element: 1

CLCI Prefix

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

1

2

No

No

Reference:

See BR 795-402-100 for complete list.

Element: 2

CLCI Service Code

Appearance

Mode

Min

Max

Series

Range

Required

Alphanumeric

2

2

No

No

Reference:

See BR 795-402-100 for complete list.

Element: 3

CLCI Modifier

Appearance

Mode

Min

Max

Series

Range

Required

Alphanumeric

2

2

No

No

Reference:

See BR 795-402-100 for complete list.

Element Rules:

Effective 4/1/01, the industry agreed to combine the 5th and 6th position CLCI S/S modifiers into one, 2-character, alphanumeric data element to increase coding power.

No.

Element Combination

Series

Separator

1.

1 . 2  3

No

2.

. 2  3

No


SECTION - POSITION

ASGM - FL

Please refer to S&E - FL for all data requirements.


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: S&E - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

O

P

P

Action Codes

I,E

I,E

O,D

O,D

I,O, C,T, M,X, D,E, R

I,O, C,T, M,X, D,E, R

-

-

-


CRIS

CABS

Data Retention

Yes

Yes

Printed on CSR

Yes

Yes

Order Section - Position: ASGM - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

P

O

P

P

Action Codes

I,O

I,O

O

O

I,O

-

I,O

-

-


CRIS

CABS

Data Retention

No

Yes

Printed on CSR

No

Yes




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.




iconectiv Confidential - Restricted Access

This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv.

Licensed Material - Property of iconectiv

Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv.