PSO

PACKET SWITCH OPTIONS

INDICATES:

The arrangement of optional multiline hunt or permanent virtual circuit features associated with a Public Packet Switched Network (PPSN) Service or permanent virtual circuit options associated with Integrated Services Digital Network (ISDN) or Broadband services.

DATE:

10/31/2014

BILLING:

CRIS and CABS

APPLICATIONS:

5ESS, Access Service, Cell Relay, FETEX-150, Frame Relay, General DataComm, ISDN BRI, Public Packet Switched Network (PPSN)


SECTION - POSITION

EXAMPLES

S&E - FL

NON-ISDN
I1   @@V/DTN 732 555-1234/PSO MLHG 4
     732 555-1020 R GM 1230-1240 Y
               or
I1   @@V/DTN 732 555-1234/PSO PVC
     CLG 732 555-2345 16 TC S4 R5
     WS S1 R3 PS S16 R32 CLD 732
     555-3456 25  


ISDN
I1   @@H/DTN 732 555-1234/CLS 10.QSZX.
     123456..NJ/DSNA 10.IBZX.234567..NJ
     /PSO FCLTYPE.X25, CLID.CLG,
     RTN.7325552345, LCN.5, PKTSZ.
     S256 R128, WNDSZ.S3 R3

Frame Relay
I1   @@V/DTN 732 555-1234/DLCI 16
     /PSO RDN 732 555-2345, RDLCI 18,
     CTR 32, MFL 5

Cell Relay
I1   @@V/DTN 732 555-1234/VPI 20, VCI 32
     /PSO RDN 732 555-2345, RVPI 21,
     RVCI 33, UPS 32

FID RULES/CONSTRAINTS:

  1. PPSN
    FID and data float on the logical line of the appropriate feature USOC (e.g. PSO MLHG... with USOC for MULTILINE Hunt Group and PSO PVC... with USOC for Permanent Virtual Circuit).
  2. The Data Terminal Number (DTN) FID is required on the same logical line.
  3. ISDN Packet Switched Bearer Service
    Section:  S&E      Position:  FL

    For mechanized flow-through, FID may be entered on the  FEATURE USOC logical line if CLS appears on the same logical line.
  4. T, F, and X order types prohibited for Access Service application.

SERVICE ORDER ACTIVITY NOTES:

  1. Elements 31 and 32 are redundant with Data Link Connection Identification (DLCI) FID when DLCI appears in a series or range or if element  2 of DLCI appears.

REFERENCES:

  1. PPSN
    Refer to GR-301-CORE, Public Packet Switched Network Generic Requirements (PPSNGR) for additional information.
  2. 5ESS
    Lucent Technologies 235-118-257, View 23.11, Keywords LCN, SENDPKTSZ, SENDPKTWD, RCV PKTSZ, RCVPKTWD, CALLIND, BILLABLE, FCLTYPE, LINKID, REMOTELCN, REMOTETN, REMOTEDNIC, PSN, INTRAGROUP.
  3. Fujitsu
    Translation Guide, ES19X-1516 M72, Keywords BC, BE, CIR, DPS, MFL, RDN, UPS.
  4. General DataComm
    PVC Configuration/Status Table, Keywords Pk Fd/Bd Size, Pk Fd/Bd Rates, Sd Fd/Bd Rates, Dest/Svc VCI.

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - FL

Required

Alphanumeric

5

91

Element: 1

Option Identifier (Non-ISDN)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

3

4

No

No

Code Set:

CodeMeaning
MLHGMultiple Line Hunt Group
PVCPermanent Virtual Circuit

Element: 2

MLHG - Hunt Group Identification Number (Non-ISDN)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

3

No

No

Data Parameters:

1-255

Element Rules:

Required when Element 1 code set MLHG is used.  Prohibited when code set PVC is used.

Element: 3

MLHG-Group Access Number Serving Region (Non-ISDN)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

3

3

No

No

Reference:

See iconectiv LERG Routing Guide for complete list.

Element Rules:

Required when Element 1 code set MLHG is used.  Prohibited when code set PVC is used.

Element: 4

MLHG-Group Access Number Serving Area (Non-ISDN)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

3

3

No

No

Data Parameters:

000-999

Element Rules:

Required when Element 1 code set MLHG is used.  Prohibited when code set PVC is used.

Element: 5

MLHG-Group Access Number End Point Number (Non-ISDN)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

4

4

Yes

Yes

Data Parameters:

0000-9999

Element Rules:

Required when Element 1 code set MLHG is used.  Prohibited when code set PVC is used.

Element: 6

MLHG - Hunting Type (Non-ISDN)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

1

8

No

No

Data Parameters:

Data characteristics are locally developed based on vendor switch.

Element Rules:

Required when Element 1 code set MLHG is used.  Prohibited when code set PVC is used.
Element supports requirements for hunting type.

Element: 7

MLHG-Group Members Indicator (Non-ISDN)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

2

2

No

No

Code Set:

CodeMeaning
GMIndicator Line Hunt Group-Group Members

Element Rules:

Required when Element 1 code set MLHG is used.  Prohibited when code set PVC is used.

Element: 8

MLHG-GM End Point Number (Non-ISDN)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

4

4

Yes

Yes

Data Parameters:

0000-9999

Element Rules:

Required when Element 1 code set MLHG is used.  Prohibited when code set PVC is used.

Element: 9

MLHG-Specific Addressing (Non-ISDN)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

1

1

No

No

Code Set:

CodeMeaning
YYes Specific Addressing
NNo Specific Addressing

Element Rules:

Required when Element 1 code set MLHG is used.  Prohibited when code set PVC is used.

Element: 10

PVC Calling/Called End Indicator (Non-ISDN)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

3

3

No

No

Code Set:

CodeMeaning
CLGCalling End
CLDCalled End

Element Rules:

Required when Element 1 code set PVC is used.  Prohibited when code set MLHG is used.

Element: 11

PVC Serving Region (Non-ISDN)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

3

3

No

No

Reference:

See iconectiv LERG Routing Guide for complete list.

Element Rules:

Required when Element 1 code set PVC is used.  Prohibited when code set MLHG is used.

Element: 12

PVC Serving Area (Non-ISDN)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

3

3

No

No

Data Parameters:

000-999

Element Rules:

Required when Element 1 code set PVC is used.  Prohibited when code set MLHG is used.

Element: 13

PVC End Point Number (Non-ISDN)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

4

4

No

No

Data Parameters:

0000-9999

Element Rules:

Required when Element 1 code set PVC is used.  Prohibited when code set MLHG is used.

Element: 14

PVC Logical Channel Number (Non-ISDN)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

4

No

No

Data Parameters:

1-4095

Element Rules:

Required when Element 1 code set PVC is used.  Prohibited when code set MLHG is used.

Element: 15

PVC - Throughput Class Indicator (Non-ISDN)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

2

2

No

No

Code Set:

CodeMeaning
TCThroughput Class

Element Rules:

Required when Element 1 code set PVC is used.  Prohibited when code set MLHG is used.

Element: 16

PVC - Throughput Class Sending Option (Non-ISDN)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

2

6

No

No

Data Parameters:

S1-S99999

Element Rules:

Required when Element 1 code set PVC is used.  Prohibited when code set MLHG is used.

Element: 17

PVC - Throughput Class Receive Option (Non-ISDN)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

2

6

No

No

Data Parameters:

R1-R99999

Element Rules:

Required when Element 1 code set PVC is used.  Prohibited when code set MLHG is used.

Element: 18

PVC Window Size Indicator (Non-ISDN)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

2

2

No

No

Code Set:

CodeMeaning
WSWindow Size

Element Rules:

Required when Element 1 code set PVC is used.  Prohibited when code set MLHG is used.

Element: 19

PVC Window Size - Sending (Non-ISDN)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

2

4

No

No

Data Parameters:

S1-S127

Element Rules:

Required when Element 1 code set PVC is used.  Prohibited when code set MLHG is used.

Element: 20

PVC Window Size - Receiving (Non-ISDN)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

2

4

No

No

Data Parameters:

R1-R127

Element Rules:

Required when Element 1 code set PVC is used.  Prohibited when code set MLHG is used.

Element: 21

PVC Packet Size Indicator (Non-ISDN)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

2

2

No

No

Code Set:

CodeMeaning
PSPacket Size

Element Rules:

Required when Element 1 code set PVC is used.  Prohibited when code set MLHG is used.

Element: 22

PVC Packet Size - Sending (Non-ISDN)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

3

4

No

No

Data Parameters:

S16, S32, S64, S128, S256, S512

Element Rules:

Required when Element 1 code set PVC is used.  Prohibited when code set MLHG is used.

Element: 23

PVC Packet Size - Receiving (Non-ISDN)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

3

4

No

No

Data Parameters:

R16, R32, R64, R128, R256, R512

Element Rules:

Required when Element 1 code set PVC is used.  Prohibited when code set MLHG is used.

Element: 24

PVC Traffic Class/Grade of Service (Non-ISDN)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

2

No

No

Data Parameters:

Data characteristics are locally developed.

Element Rules:

The Consultative Committee on International Telephony and Telegraphy (CCITT) refers to this as Transit Delay Selection in milliseconds.
Allowed only when Element 1 code set PVC is used. Prohibited when code set MLHG is used.

Element: 25

PVC Attribute Names (5ESS-ISDN)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

3

10

No

No

Code Set:

CodeMeaning
LCNLogical Channel Number
PKTSZPacket Size
WNDSZWindow Size
CLIDLogical Channel Call Indicator
BILLBillable Logical Channel Number
FCLTYPEDestination Facility Type
LINKIDLogical Link Identification
RLCNRemote Logical Channel Number
RTNRemote TN
RDNICRemote Data Network ID Code
PSNPacket Switching Number (where gateway resides)
INTRAGROUPPacket Switching Intragroup AMA Billing

Element: 26

PVC Attribute Values (5ESS-ISDN)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

1

10

Yes

No

Code Set:

CodeMeaning
PKTSZ Attribute Value
R128Receive 128 Bytes (switch default)
R256Receive 256 Bytes
S128Send 128 Bytes (switch default)
S256Send 256 Bytes
WNDSZ Attribute Value
R2Receive 2 packets (switch default)
R3Receive 3 packets
R7Receive 7 packets
S2Send 2 packets (switch default)
S3Send 3 packets
S7Send 7 packets
CLID Attribute Value
CLGCalling
CLDCalled
BILL Attribute Value
YYes (switch default)
NNo
FCLTYPE Attribute Value
INETInternet Protocol (5E14)
X25X.25 Protocol
X75X.75 Protocol
X75PX.75 Prime Protocol
INTRAGROUP Attribute Value
YYes
NNo

Data Parameters:

LCN Attribute Value
1-127
LINKID Attribute Value
1-255
RLCN Attribute Value
1-4095
RTN Attribute Value
10 digits in form of NPANXXXXXX
RDNIC Attribute Value
0000-9999
PSN Attribute Value
1-255

Element Rules:

PKTSZ attribute values of R128, R256, S128, or S256 must appear in a series of two attribute values, one for Send and one for Receive.  The series separator is a space.
WNDSZ attribute values of R2, R3, S2, or S3 must appear in a series of two attribute values, one for Send and one for Receive.
When CLID attribute value of CLG is present, the FCLTYPE attribute value cannot equal X75, and RTN attribute name and value are required.
When CLID attribute value of CLD is present, the RTN attribute name and value are prohibited.
If BILL attribute value is N, the INTRAGROUP attribute value must be N.
If FCLTYPE attribute value is X25, then LINKID, RDNIC, and PSN attribute names and values are prohibited; RTN and CLID attribute names and values are required; RLCN attribute name and value are optional.
If FCLTYPE attribute value is X75, then LINKID, RDNIC, RLCN, and PSN attribute names and values are required; RTN attribute name and value are prohibited; CLID attribute name with CLD attribute value are required; INTRAGROUP attribute value must be N.
If FCLTYPE attribute value is X75P, then LINKID, RDNIC, RTN, CLID, and PSN attribute names and values are required; RLCN attribute name and value are optional; INTRAGROUP attribute value must be N.
If FCLTYPE attribute value is INET, then LINKID, RDNIC, RLCN, and RTN attribute names and values are prohibited.  CLID attribute name with CLG attribute value are required.
WNDSZ values of R7 and S7 are only valid when FCLTYPE value is INET.

Element: 27

Remote Data Terminal Indicator (FETEX-150 Broadband)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

3

3

No

No

Code Set:

CodeMeaning
RDNRemote Data Terminal Number

Element: 28

Remote Data Terminal Number Serving Region (FETEX-150 Broadband)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

3

3

No

No

Reference:

See iconectiv LERG Routing Guide for complete list.

Element: 29

Remote Data Terminal Number Serving Area (FETEX-150 Broadband)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

3

3

No

No

Reference:

See iconectiv LERG Routing Guide for complete list.

Element: 30

Remote Data Terminal Number End Point Number (FETEX-150 Broadband)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

4

4

No

No

Data Parameters:

0000-9999

Element: 31

Frame Relay Remote Data Link Connection Identification Indicator (FETEX-150 Broadband)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

5

5

No

No

Code Set:

CodeMeaning
RDLCIRemote Data Link Connection Identification

Element: 32

Frame Relay Remote Data Link Connection Identification Number (FETEX-150 Broadband)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

2

4

No

No

Data Parameters:

16-1007

Element: 33

Frame Relay PVC Attribute Names (FETEX-150 Broadband)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

2

3

No

No

Code Set:

CodeMeaning
BCBurst Committed Size
BEBurst Excess Size
CIRCommitted Information Rate
MFLMaximum Frame Length

Element: 34

Frame Relay PVC Attribute Values (FETEX-150 Broadband)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

4

No

No

Data Parameters:

0-2(BC in seconds)
0-4(BE in seconds)
1-1536(CIR in Kbps)
5-4096(MFL)

Element: 35

Cell Relay Remote Virtual Path Identifier Indicator (FETEX-150 Broadband, Generic Cell Relay)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

4

4

No

No

Code Set:

CodeMeaning
RVPIRemote Virtual Path Identifier

Element: 36

Cell Relay Remote Virtual Path Identifier Number (FETEX-150 Broadband, Generic Cell Relay)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

2

No

No

Data Parameters:

0-63

Element: 37

Cell Relay Remote Virtual Channel Identifier Indicator (FETEX-150 Broadband, Generic Cell Relay)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

4

4

No

No

Code Set:

CodeMeaning
RVCIRemote Virtual Channel Identifier

Element: 38

Cell Relay Remote Virtual Channel Identifier Number (FETEX-150 Broadband, General DataComm, Standard Values)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

4

Yes

Yes

Data Parameters:

32-1007FETEX-150
0-1023General DataComm
0-31Standard Values (ITU-T Reserved)
32-1023Standard Values (ITU-T Non-Reserved)

Element: 39

Cell Relay PVC Attribute Names (FETEX-150 Broadband, General DataComm)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

3

3

No

No

Code Set:

CodeMeaning
CIRCommitted Information Rate (FETEX-150)
DPSDown Peak Speed (FETEX-150)
MBSMaximum Burst Size (General DataComm)
PCRPeak Cell Rate (General DataComm)
SCRSustained Cell Rate (General DataComm)
UPSUpper Peak Speed (FETEX-150)

Element Rules:

If code set MBS appears, code set SCR is also required.  Code set SCR may appear only if code set MBS is present.

Element: 40

Cell Relay PVC Attribute Values (FETEX-150 Broadband, General DataComm)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

8

No

No

Data Parameters:

1-1536(CIR in Kbps) (FETEX-150)
32-156000(DPS or UPS in Kbps) (FETEX-150)
1-16777215(MBS in Cells) (General DataComm)
1-7113540(PCR in Kbps) (General DataComm)
1-7113540(SCR in Kbps) (General DataComm)

No.

Element Combination

Series

Separator

1.

1 SP 2 SP 3 SP 4 - 5 SP 6 SP 7 SP 8 SP 9

Yes

, SP

2.

1 SP 10 SP 11 SP 12 - 13 SP 14 SP 15 SP 16 SP 17 SP 18 SP 19 SP 20 SP 21 SP 22 SP 23 SP 10 SP 11 SP 12 - 13 SP 14

No

3.

1 SP 10 SP 11 SP 12 - 13 SP 14 SP 15 SP 16 SP 17 SP 18 SP 19 SP 20 SP 21 SP 22 SP 23 SP 24 SP 10 SP 11 SP 12 - 13

No

4.

25 . 26

Yes

, SP

5.

27 SP 28 SP 29 - 30 , SP [ 31 SP 32 , SP [ 33 SP 34 , SP ] , SP ]

Yes

, SP

6.

27 SP 28 SP 29 - 30 , SP [ 33 SP 34 , SP ]

Yes

, SP

7.

27 SP 28 SP 29 - 30 , SP [ 35 SP 36 , SP 37 SP 38 , SP [ 39 SP 40 , SP ] , SP ]

Yes

, SP

8.

27 SP 29 - 30 , SP [ 31 SP 32 , SP [ 33 SP 34 , SP ] , SP ]

Yes

, SP

9.

27 SP 29 - 30 , SP [ 33 SP 34 , SP ]

Yes

, SP

10.

27 SP 29 - 30 , SP [ 35 SP 36 , SP 37 SP 38 , SP [ 39 SP 40 , SP ] , SP ]

Yes

, SP

11.

27 SP 30 , SP [ 31 SP 32 , SP [ 33 SP 34 , SP ] , SP ]

Yes

, SP

12.

27 SP 30 , SP [ 33 SP 34 , SP ]

Yes

, SP

13.

27 SP 30 , SP [ 35 SP 36 , SP 37 SP 38 , SP [ 39 SP 40 , SP ] , SP ]

Yes

, SP

14.

35 SP 36

No

15.

35 SP 36 , SP 37 SP 38

No

16.

35 SP 36 , SP 37 SP 38 , SP [ 39 SP 40 , SP ]

No

17.

35 SP 36 , SP [ 39 SP 40 , SP ]

No

18.

37 SP 38

No

19.

37 SP 38 , SP [ 39 SP 40 , SP ]

No

20.

39 SP 40

Yes

, SP


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: S&E - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

O

P

P

Action Codes

I,E

I,E

O,D

O,D

I,O, C,T, D,E, R

I,O, C,T, D,E, R

C,T, R

-

-


CRIS

CABS

Data Retention

Yes

Yes

Printed on CSR

Yes

Yes




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.