PTW

PROVISION TWO-WIRE

INDICATES:

That the circuit is to be provisioned as 2-wire when wiring information cannot be determined from USOC.

DATE:

10/30/1992

BILLING:

CRIS and CABS

APPLICATIONS:

General Purpose


SECTION - POSITION

EXAMPLES

S&E - FL

I1   @@A/CLS 10.PLNA.123..NJ/PTW

               or

I1   @@A/TN 4200/PSM.CLNZ/PTW

FID RULES/CONSTRAINTS:

  1. T, F, and X order types prohibited for Access Service application.
  2. X action code prohibited on Access Service orders.

SERVICE ORDER ACTIVITY NOTES:

  1. It is intended that this FID would not be entered at service order negotiation time, but would be added on a supplemental pass when circuit design requires that the initial four-wire assignment must be changed to a two-wire assignment.

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - FL

Prohibited

0

0


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: S&E - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

O

P

P

Action Codes

I,E

I,E

O,D

O,D

I,O, C,T, D,E, M,X, R

I,O, C,T, D,E, M,X, R

I,O, C,T, R

-

-


CRIS

CABS

Data Retention

Yes

Yes

Printed on CSR

Yes

Yes




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.




iconectiv Confidential - Restricted Access

This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv.

Licensed Material - Property of iconectiv

Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv.