QCK

QUICK CONFERENCE KEY OPTION

INDICATES:

The Quick Conference option assigned to the station.

DATE:

9/19/1991

BILLING:

CRIS

APPLICATIONS:

DMS-100


SECTION - POSITION

EXAMPLES

S&E - FL

I1   @@E/KEY 6/QCK USER.N,
     QCKDN.B11

                   or

I1   @@E/KEY 6/QCK USER.Y

FID RULES/CONSTRAINTS:

  1. The QCK FID may not be entered on a key which has a directory number associated with it.
  2. To initiate a mechanzied SOAC/MAS (Service Order Analysis and Control/Memory Administration System) flow through, FID must be entered on the Quick Conference option USOC logical line.

REFERENCES:

  1. Northern Telecom Practice 297-2101-310, Option QCK.

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - FL

Required

Alphanumeric

6

22

Element: 1

User Attribute Name

Appearance

Mode

Min

Max

Series

Range

Required

Alphabetic

4

4

No

No

Code Set:

CodeMeaning
USERUser Programmable

Element: 2

User Attribute Value

Appearance

Mode

Min

Max

Series

Range

Required

Alphabetic

1

1

No

No

Code Set:

CodeMeaning
YYes - User may program the QCKDN field value
NNo  - QCKDN field may only be set/altered via service order or Table Control

Element: 3

QCK Directory Number Attribute Name

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

5

5

No

No

Code Set:

CodeMeaning
QCKDNQCK Directory Number

Element: 4

QCK Directory Number Attribute Value

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

2

8

No

No

Data Parameters:

0-9 and B

Symbols:

Asterisk, Hyphen

Element Rules:

Alpha character is the first character of data entry.

No.

Element Combination

Series

Separator

1.

1 . 2

No

2.

1 . 2 , SP 3 . 4

No


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: S&E - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

O

P

P

Action Codes

I,E

I,E

O,D

O,D

I,O, C,T, E,D, M,X, R

I,O, C,T, E,D, M,X, R

I,O, C,T, R

-

-


CRIS

CABS

Data Retention

Yes

No

Printed on CSR

Yes

No




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.