RCU |
RESTRICT CASUAL USE |
INDICATES: |
The subscriber is prohibited from accessing the usage sensitive features, that are open to use by any subscriber on the switch, through the use of access codes. |
DATE: |
11/23/2005 |
BILLING: |
CRIS and CABS |
APPLICATIONS: |
1AESS, 5ESS, AXE, DMS-10, DMS-100, GTD-5 EAX, ISDN BRI, TL1 |
SECTION - POSITION |
EXAMPLES |
S&E - FL |
|
C1 @@A/TN 732 555-1234 |
FID RULES/CONSTRAINTS: |
|
SERVICE ORDER ACTIVITY NOTES: |
|
REFERENCES: |
|
SECTION - POSITION |
APPEARANCE |
MODE |
MIN |
MAX |
S&E - FL |
Optional |
Alphanumeric |
0 |
30 |
Element: 1 |
Restrict Line Feature |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphabetic |
1 |
1 |
No |
No |
Code Set: |
||||
|
Element: 2 |
Restrict Line Feature (1AESS, TL1, 5ESS, DMS-100, DMS-10, GTD-5 EAX) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphanumeric |
2 |
5 |
Yes |
No |
Code Set: |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Element: 3 |
Deny Options Attribute Name (DMS-100 NA005B, DMS-100 NA007) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphabetic |
7 |
7 |
No |
No |
Code Set: |
||||
|
Element Rules: |
Element required when code set CSMI is used on element 2. |
Element: 4 |
CSMI Deny Options (DMS-100 NA005B) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphabetic |
3 |
4 |
Yes |
No |
Code Set: |
||||||||||
|
Element Rules: |
||
|
Element: 5 |
SDN Deny Options (DMS-100 NA007) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphabetic |
3 |
3 |
No |
No |
Code Set: |
||||
|
Element Rules: |
Element required when SDN is used on element 2. |
Element: 6 |
Call Transfer Fraud Prevention (CTFP) Screening Name (DMS-100 NA013) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphabetic |
6 |
6 |
No |
No |
Code Set: |
||||
|
Element Rules: |
Element required when code set CTFP is used on element 2. |
Element: 7 |
CTFP Screening Value (DMS-100 NA013) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphabetic |
2 |
3 |
No |
No |
Code Set: |
||||||
|
Element Rules: |
Element required when code set CTFP is used on element 2. |
Element: 8 |
CTFP Throttling Name (DMS-100 NA013) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphabetic |
8 |
8 |
No |
No |
Code Set: |
||||
|
Element Rules: |
Element required when code set CTFP is used on element 2. |
Element: 9 |
CTFP Throttling Value (DMS-100 NA013) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphabetic |
2 |
3 |
No |
No |
Code Set: |
||||||
|
Element Rules: |
Element required when code set CTFP is used on element 2. |
No. |
Element Combination |
Series |
Separator |
1. |
1 |
No |
|
2. |
2 |
Yes |
, SP |
3. |
2 SP 3 . 4 |
No |
|
4. |
2 SP 3 . 5 |
No |
|
5. |
2 SP 6 . 7 , SP 8 . 9 |
No |
ORDER TYPE/ACTION CODE/FID RELATIONSHIPS |
Order Section - Position: S&E - FL
|
Order Type |
N |
T |
F |
D |
C |
R |
X |
P |
A |
Presence |
O |
O |
O |
O |
O |
O |
O |
P |
P |
Action Codes |
I,E |
I,E |
O,D |
O,D |
I,O, C,T, D,E, M,X, R |
I,O, C,T, D,E, M,X, R |
I,O, C,T, R |
- |
- |
CRIS |
CABS |
|
Data Retention |
Yes |
Yes |
Printed on CSR |
Yes |
Yes |
Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure. |
iconectiv Confidential - Restricted Access This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv. |
Licensed Material - Property of iconectiv Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv. |