RDCI

REMOTE DIGITAL SUBSCRIBER LINE ACCESS MULTIPLEXER (DSLAM) CLLI CODE

INDICATES:

The CLLI identification associated with the remote Digital Subscriber Line Access Multiplexer (DSLAM).

DATE:

12/8/2005

BILLING:

CRIS and CABS

APPLICATIONS:

Data Service, Digital Subscriber Line (DSL)


SECTION - POSITION

EXAMPLES

S&E - FL

I1    @@A/CLS 38.ARXS.123456..NJ
      /PROV OR/RDCI PSWYNJ14H01
      /LSO 732 555
      /ADSL DMTS, DN.7100K, UP.768K

ASGM - FL

IF1   /CA 14/PR 160/BP 0
      /RDEQ 16 MAIN ST.
      /RDPI 2-1-4/RDCI CHCGILZACGO

FID RULES/CONSTRAINTS:

  1. T, F and  X order types prohibited for Access Service application.
  2. X action code prohibited on Access Service orders.
  3. Section:  ASGM             Position: FL
    FID is entered in the Outside Plant Facilities Subset and /or Line or Station Transfer Set.

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - FL

Required

Alphanumeric

8

11

Element: 1

COMMON LANGUAGE Geographical Code

Appearance

Mode

Min

Max

Series

Range

Required

Alphanumeric

4

4

No

No

Symbols:

Space

Reference:

See BR 795-100-100 for more information on CLLI codes or go to www.commonlanguage.com/clli.

Element Rules:

Required as specified in BR 795-100-100.

Element: 2

COMMON LANGUAGE Geopolitical Code

Appearance

Mode

Min

Max

Series

Range

Required

Alphabetic

2

2

No

No

Reference:

See BR 795-100-100 for more information on CLLI codes or go to www.commonlanguage.com/clli.

Element Rules:

Required as specified in BR 795-100-100.

Element: 3

CLLI Network Site Code

Appearance

Mode

Min

Max

Series

Range

Required

Alphanumeric

2

2

No

No

Reference:

See BR 795-100-100 for more information on CLLI codes or go to www.commonlanguage.com/clli.

Element Rules:

Required as specified in BR 795-100-100

Element: 4

CLLI Network Entity Code

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

3

3

No

No

Reference:

See BR 795-100-100 for more information on CLLI codes or go to www.commonlanguage.com/clli.

Element Rules:

Required as specified in BR 795-100-100.

No.

Element Combination

Series

Separator

1.

1  2  3

No

2.

1  2  3  4

No


SECTION - POSITION

ASGM - FL

Please refer to S&E - FL for all data requirements.


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: S&E - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

O

P

P

Action Codes

I, E

I, E

O, D

O, D

I, O, C, T, D, E, M, X, R

I, O, C, T, D, E, M, X, R

I, O, C, T, R

-

-


CRIS

CABS

Data Retention

Yes

Yes

Printed on CSR

Yes

Yes

Order Section - Position: ASGM - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

P

O

P

P

Action Codes

I

I

O

O

I,O

-

I,O

-

-


CRIS

CABS

Data Retention

No

No

Printed on CSR

No

No




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.




iconectiv Confidential - Restricted Access

This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv.

Licensed Material - Property of iconectiv

Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv.