RGR

REGISTER READING

INDICATES:

The register reading or readings which is required to bill message units when measured service is provided.

DATE:

9/7/1989

BILLING:

CRIS and CABS

APPLICATIONS:

General Purpose


SECTION - POSITION

EXAMPLES

S&E - FL

I1   @@A/TN 273-3132/RGN 6131
     /RGR 9861
I1   @@A/TN 273-3133/RGN 6132
     /RGR 9004

        or

I1   @@A/RGN 6131D, 2491E
     7214N/RGR 9861D, 8411E
     10842N

FID RULES/CONSTRAINTS:

  1. T, F, and X order types prohibited for Access Service application.

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - FL

Required

Alphanumeric

1

22

Element: 1

Register Reading

Appearance

Mode

Min

Max

Series

Range

Required

Numeric

1

5

No

No

Data Parameters:

0-99999

Element: 2

Register Time of Day Designation

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

1

1

No

No

Code Set:

CodeMeaning
DDay
EEvening
NNight

No.

Element Combination

Series

Separator

1.

1

No

2.

1  2 , SP 1  2 , SP 1  2

No


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: S&E - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

O

P

P

Action Codes

I

I

O

O

I,O, C,T, D,E, R

I,O, C,T, D,E, R

C,T, R

-

-


CRIS

CABS

Data Retention

No

No

Printed on CSR

No

No




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.