ROL

RING ON LINE

INDICATES:

The line or lines to which the ringer in a key telephone is connected.

DATE:

10/31/2014

BILLING:

CRIS and CABS

APPLICATIONS:

DMS-100


SECTION - POSITION

EXAMPLES

S&E - FL

Telephone Number Format
I1   @@A/TN 732 555-1234/FEA P 3112, 3113
     /ROL 3112

I1   @@A/TN 732 555-1234/FEA P 3112, 3113
     /ROL C

Coded Entry Format
I1   @@A/TN 732 555-1234/FEA P 3112, 3113
     /ROL C

DMS-100
I1   @@A/TN 732 555-1234/ROL Y

FID RULES/CONSTRAINTS:

  1. The presence of this FID without data infers Y for yes for Ringing Indicator (Element 15).
  2. T, F, and X order types prohibited for Access Service application.
  3. X action code prohibited on Access Service orders.

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - FL

Optional

Alphanumeric

0

30

Element: 1

Coded Entry

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

1

1

No

No

Code Set:

CodeMeaning
CRinger common to all lines

Element: 2

Numbering Plan Area Code

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

3

3

No

No

Reference:

See iconectiv LERG Routing Guide for complete list.

Element Rules:

NPA is required when it cannot be derived first from the NPA previously entered on the same logical line, second from the fielded TN, or third from the fielded EX in the Identification section.

Element: 3

Central Office Code

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

3

3

No

No

Reference:

See iconectiv LERG Routing Guide for complete list.

Element Rules:

Central Office Code is required when the NPA is entered, or when it is different from the Central Office Code previously entered on the same logical line, or when the Central Office Code is different from that of the main account number in the fielded TN.

Element: 4

Line Number

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

4

4

Yes

No

Data Parameters:

0000-9999

Element Rules:

Required for Exchange Telephone Number Format.

Element: 5

CLCI Prefix

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

1

2

No

No

Reference:

See BR 795-402-100 for complete list.

Element Rules:

Required when CLCI-Serial Number format is used.

Element: 6

CLCI Service Code

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

2

2

No

No

Reference:

See BR 795-402-100 for complete list.

Element: 7

CLCI Modifier

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

2

2

No

No

Reference:

See BR 795-402-100 for complete list.

Element Rules:

Effective 4/1/01, the industry agreed to combine the 5th and 6th position CLCI S/S modifiers into one, 2-character, alphanumeric data element to increase coding power.

Element: 8

CLCI Serial Number

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

6

No

No

Data Parameters:

1-999999

Element: 9

CLCI Suffix

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

3

No

No

Data Parameters:

1-999

Element: 10

COMMON LANGUAGE Company Assigning Circuit Identification

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

2

4

No

No

Reference:

See BR 751-100-112 for complete list.

Element: 11

CLCI Segment Name

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

1

3

No

No

Data Parameters:

0 - 9
A - Z

Element: 12

CLCI Extension Number or Trunk Identifier

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

1

5

No

No

Data Parameters:

D1-D9999When Primary Line Identifier includes the Direct Inward Dialing (DID) FID
F1-F9999Indicates Simulated Facility Number (SFN)
G1-G9999When Primary Line Identifier includes the Outgoing Only Service (OGO) FID
P1-P9999When Primary Line Identifier includes the Private Branch Exchange (PBX) Station Number ( PX ) FID.
S1-S9999When Primary Line Identifier includes the Special Identifying Telephone Number Supplement (SIS)  and Special Identifying Telephone Number (SIT ) FIDs
T0-T4999, T6952-T9999When Primary Line Identifier includes the Terminal Number - Multiline Group (TER) FID
T5000-T6951When Primary Line Identifier includes the  Two-Way Trunk Member Number (TWT ) FID
X1-X9999When Primary Line Identifier includes the Extra Number ( XN ) FID.

Element Rules:

Common Language Practice BR 795-402-100 defines this element as 1-5 alphas, numerics,or alphanumerics. The above Data Parameters have been defined to meet provisioning requirements.

Element: 13

PBX Station Number

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

4

No

No

Data Parameters:

1-9999

Element: 14

Simple Numbering Plan

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

4

No

No

Data Parameters:

1-9999

Element: 15

Ringing Indicator (DMS-100)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

1

1

No

No

Code Set:

CodeMeaning
YYes
NNo

Element Rules:

The absence of this element infers Y for yes.

No.

Element Combination

Series

Separator

1.

1

No

2.

2 SP 3 - 4

Yes

, SP

3.

3 - 4

Yes

, SP

4.

4

Yes

, SP

5.

5 . 6  7 . 2 . 3 . 4

Yes

, SP

6.

5 . 6  7 . 2 . 3 . 4 .. 11

Yes

, SP

7.

5 . 6  7 . 2 . 3 . 4 . 12

Yes

, SP

8.

5 . 6  7 . 2 . 3 . 4 . 12 . 11

Yes

, SP

9.

5 . 6  7 . 8 . 9 . 10

Yes

, SP

10.

5 . 6  7 . 8 . 9 . 10 . 11

Yes

, SP

11.

5 . 6  7 . 8 .. 10

Yes

, SP

12.

5 . 6  7 . 8 .. 10 . 11

Yes

, SP

13.

. 6  7 . 2 . 3 . 4

Yes

, SP

14.

. 6  7 . 2 . 3 . 4 .. 11

Yes

, SP

15.

. 6  7 . 2 . 3 . 4 . 12

Yes

, SP

16.

. 6  7 . 2 . 3 . 4 . 12 . 11

Yes

, SP

17.

. 6  7 . 8 . 9 . 10

Yes

, SP

18.

. 6  7 . 8 . 9 . 10 . 11

Yes

, SP

19.

. 6  7 . 8 .. 10

Yes

, SP

20.

. 6  7 . 8 .. 10 . 11

Yes

, SP

21.

13

Yes

, SP

22.

14

Yes

, SP

23.

15

No


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: S&E - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

O

P

P

Action Codes

I,E

I,E

O,D

O,D

I,O, C,T, X,D, E,R, M

I,O, C,T, X,D, E,R, M

C,T, R

-

-


CRIS

CABS

Data Retention

Yes

Yes

Printed on CSR

Yes

Yes




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.




iconectiv Confidential - Restricted Access

This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv.

Licensed Material - Property of iconectiv

Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv.