ROL |
RING ON LINE |
INDICATES: |
The line or lines to which the ringer in a key telephone is connected. |
DATE: |
10/31/2014 |
BILLING: |
CRIS and CABS |
APPLICATIONS: |
DMS-100 |
SECTION - POSITION |
EXAMPLES |
S&E - FL |
|
Telephone Number Format |
FID RULES/CONSTRAINTS: |
|
SECTION - POSITION |
APPEARANCE |
MODE |
MIN |
MAX |
S&E - FL |
Optional |
Alphanumeric |
0 |
30 |
Element: 1 |
Coded Entry |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphabetic |
1 |
1 |
No |
No |
Code Set: |
||||
|
Element: 2 |
Numbering Plan Area Code |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
3 |
3 |
No |
No |
Reference: |
See iconectiv LERG Routing Guide for complete list. |
Element Rules: |
NPA is required when it cannot be derived first from the NPA previously entered on the same logical line, second from the fielded TN, or third from the fielded EX in the Identification section. |
Element: 3 |
Central Office Code |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
3 |
3 |
No |
No |
Reference: |
See iconectiv LERG Routing Guide for complete list. |
Element Rules: |
Central Office Code is required when the NPA is entered, or when it is different from the Central Office Code previously entered on the same logical line, or when the Central Office Code is different from that of the main account number in the fielded TN. |
Element: 4 |
Line Number |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
4 |
4 |
Yes |
No |
Data Parameters: |
||
|
Element Rules: |
Required for Exchange Telephone Number Format. |
Element: 5 |
CLCI Prefix |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphanumeric |
1 |
2 |
No |
No |
Reference: |
See BR 795-402-100 for complete list. |
Element Rules: |
Required when CLCI-Serial Number format is used. |
Element: 6 |
CLCI Service Code |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphanumeric |
2 |
2 |
No |
No |
Reference: |
See BR 795-402-100 for complete list. |
Element: 7 |
CLCI Modifier |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphanumeric |
2 |
2 |
No |
No |
Reference: |
See BR 795-402-100 for complete list. |
Element Rules: |
Effective 4/1/01, the industry agreed to combine the 5th and 6th position CLCI S/S modifiers into one, 2-character, alphanumeric data element to increase coding power. |
Element: 8 |
CLCI Serial Number |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
1 |
6 |
No |
No |
Data Parameters: |
||
|
Element: 9 |
CLCI Suffix |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
1 |
3 |
No |
No |
Data Parameters: |
||
|
Element: 10 |
COMMON LANGUAGE Company Assigning Circuit Identification |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphabetic |
2 |
4 |
No |
No |
Reference: |
See BR 751-100-112 for complete list. |
Element: 11 |
CLCI Segment Name |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphanumeric |
1 |
3 |
No |
No |
Data Parameters: |
||||
|
Element: 12 |
CLCI Extension Number or Trunk Identifier |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphanumeric |
1 |
5 |
No |
No |
Data Parameters: |
||||||||||||||||
|
Element Rules: |
Common Language Practice BR 795-402-100 defines this element as 1-5 alphas, numerics,or alphanumerics. The above Data Parameters have been defined to meet provisioning requirements. |
Element: 13 |
PBX Station Number |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
1 |
4 |
No |
No |
Data Parameters: |
||
|
Element: 14 |
Simple Numbering Plan |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
1 |
4 |
No |
No |
Data Parameters: |
||
|
Element: 15 |
Ringing Indicator (DMS-100) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphabetic |
1 |
1 |
No |
No |
Code Set: |
||||||
|
Element Rules: |
The absence of this element infers Y for yes. |
No. |
Element Combination |
Series |
Separator |
1. |
1 |
No |
|
2. |
2 SP 3 - 4 |
Yes |
, SP |
3. |
3 - 4 |
Yes |
, SP |
4. |
4 |
Yes |
, SP |
5. |
5 . 6 7 . 2 . 3 . 4 |
Yes |
, SP |
6. |
5 . 6 7 . 2 . 3 . 4 .. 11 |
Yes |
, SP |
7. |
5 . 6 7 . 2 . 3 . 4 . 12 |
Yes |
, SP |
8. |
5 . 6 7 . 2 . 3 . 4 . 12 . 11 |
Yes |
, SP |
9. |
5 . 6 7 . 8 . 9 . 10 |
Yes |
, SP |
10. |
5 . 6 7 . 8 . 9 . 10 . 11 |
Yes |
, SP |
11. |
5 . 6 7 . 8 .. 10 |
Yes |
, SP |
12. |
5 . 6 7 . 8 .. 10 . 11 |
Yes |
, SP |
13. |
. 6 7 . 2 . 3 . 4 |
Yes |
, SP |
14. |
. 6 7 . 2 . 3 . 4 .. 11 |
Yes |
, SP |
15. |
. 6 7 . 2 . 3 . 4 . 12 |
Yes |
, SP |
16. |
. 6 7 . 2 . 3 . 4 . 12 . 11 |
Yes |
, SP |
17. |
. 6 7 . 8 . 9 . 10 |
Yes |
, SP |
18. |
. 6 7 . 8 . 9 . 10 . 11 |
Yes |
, SP |
19. |
. 6 7 . 8 .. 10 |
Yes |
, SP |
20. |
. 6 7 . 8 .. 10 . 11 |
Yes |
, SP |
21. |
13 |
Yes |
, SP |
22. |
14 |
Yes |
, SP |
23. |
15 |
No |
ORDER TYPE/ACTION CODE/FID RELATIONSHIPS |
Order Section - Position: S&E - FL
|
Order Type |
N |
T |
F |
D |
C |
R |
X |
P |
A |
Presence |
O |
O |
O |
O |
O |
O |
O |
P |
P |
Action Codes |
I,E |
I,E |
O,D |
O,D |
I,O, C,T, X,D, E,R, M |
I,O, C,T, X,D, E,R, M |
C,T, R |
- |
- |
CRIS |
CABS |
|
Data Retention |
Yes |
Yes |
Printed on CSR |
Yes |
Yes |
Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure. |
iconectiv Confidential - Restricted Access This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv. |
Licensed Material - Property of iconectiv Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv. |