SCNL

SCREENING NUMBER LIST

INDICATES:

The CLASS or Advanced Intelligent Network (AIN) screening number lists that are assigned to a directory number.

DATE:

10/31/2014

BILLING:

CRIS

APPLICATIONS:

Advanced Intelligent Network (AIN), Centrex, CLASS, ISDN BRI, SanteraOne, STROM-DCO, TL1


SECTION - POSITION

EXAMPLES

S&E - FL

TL1
I1   @@A/TN 732 555-3399/DRDT DABG
     /SCNL DACWNL 5553344, 7776565,
     3334545, PV 5556481-6483

TL1
Multi-line Hunting

IHML 24-TER H1-3/SCLF US
     /SCNL SCFNL 5553498, 5553301

Advanced Intelligent Network (AIN)
I1   @@V/TN 732 555-3434/SCNL
     908 555-4321, 908 555-8767

SanteraOne
I1   @@A/TN 732 555-1234
     /DRDT DRCW/SCNL
     DACWNL 7325551234,
     9733334545

FID RULES/CONSTRAINTS:

  1. SERIES AND RANGE ENTRIES - PROCESSING
    Service Order Analysis and Control System (SOAC) should process series and range data entries using the DUPLICATE algorithm.

REFERENCES:

  1. TL1
    TR-NWT-000199, Keywords SCFNL, SCRNL, DACWNL.
  2. SanteraOne
    Santera Systems Inc., DNCT View, Keywords DACWNL, SCFNL, SCRNL.

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - FL

Required

Alphanumeric

4

32

Element: 1

Type of Screening Number List Feature Name (TL1, SanteraOne, DCO)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

5

6

No

No

Code Set:

CodeMeaning
DACWNLDistinctive Alerting/Call Waiting Number List
SCFNLSelective Call Forwarding Number List
SCRNLSelective Call Rejection Number List

Element: 2

Screening Number Type (TL1)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

1

2

No

No

Code Set:

CodeMeaning
XExtension
PVPrivate

Element Rules:

The absence of this element indicates a Public (PB) number.

Element: 3

Screening Numbers (TL1, SanteraOne, DCO)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

2

10

Yes

Yes

Element Rules:

(TL1)
When element 1 code set SCFNL appears, the Screening Numbers allowed in series is a maximum of 31.
The amount of Screening Numbers allowed in series should equal the SCFNLS value following the SCLF FID.
(SanteraOne)
When Element 1 Code Set SCFNL or SCRNL appears, the screening Numbers allowed in series is a maximum of 31.

Element: 4

Numbering Plan Area Code (AIN)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

3

3

No

No

Reference:

See iconectiv LERG Routing Guide for complete list.

Element: 5

Central Office Code (AIN)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

3

3

No

No

Reference:

See iconectiv LERG Routing Guide for complete list.

Element: 6

Line Number (AIN)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

4

4

No

No

Data Parameters:

0000-9999

Element: 7

No Telephone Numbers In List (AIN)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

4

4

No

No

Data Parameters:

NONE

No.

Element Combination

Series

Separator

1.

1 SP [ 2 SP 3 , SP ]

Yes

; SP

2.

1 SP 3

Yes

; SP

3.

1 SP 3 , SP [ 2 SP 3 , SP ]

Yes

; SP

4.

4 SP 5 - 6

Yes

, SP

5.

7

No


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: S&E - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

O

P

P

Action Codes

I,E

I,E

O,D

O,D

I,O, C,T, D,E, M,X, R

I,O, C,T, D,E, M,X, R

I,O, C,T, R

-

-


CRIS

CABS

Data Retention

Yes

No

Printed on CSR

Yes

No




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.




iconectiv Confidential - Restricted Access

This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv.

Licensed Material - Property of iconectiv

Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv.