SFG

SIMULATED FACILITY GROUP IDENTIFIER

INDICATES:

The Simulated/Virtual Facilities Group Identifier and may also indicate the group number or group type that is associated with a line or register.

DATE:

7/29/2010

BILLING:

CRIS and CABS

APPLICATIONS:

1AESS, 2/2BESS, 5ESS, 800 Service, Access Service, Access Service Request (ASR), Centrex, DMS-100, EWSD, FETEX-150, GTD-5 EAX, ISDN BRI, ISDN PRI, Public Packet Switched Network (PPSN), TL1, Wide Area Telephone Service (WATS)


SECTION - POSITION

EXAMPLES

S&E - LH

ISFG A 222, 223

     or

ISFG A 124 O, 716 O

     or

ISFG B 129 T, 717 T

1AESS GENERIC 8 or Later
ISFG A 598 3

S&E - FL

I1   @@A/TN 732 555-1234/SFG 13


        or

I1   @@A/TN 732 555-1234/SFG 125 O, 129 T


        or

I1   @@A/TN 732 555-1234/SFG 200 INWATS

I1   @@A/TN 732 555-1234/SFG 20/GSZ 512


1AESS GENERIC 8 or Later
I1   @@A/SIT 800 555-1234
     /SIS 1/SFG 598 3

FID RULES/CONSTRAINTS:

  1. Section:  S&E    Position:  LH
    The FID is followed by an alphabetic Group Indicator and the Group Numbers in the sequence in which the customer requests the groups to overflow.
  2. Section:  S&E    Position:  LH
    FID is prohibited on CABS orders.
  3. T, F, and X order types prohibited for Access Service application.
  4. X action code prohibited on Access Service orders.
  5. SERIES AND RANGE ENTRIES - PROCESSING
    Service Order Analysis and Control System (SOAC) should process series and range data entries using the DUPLICATE algorithm.
  6. GTD-5 EAX
    FID is used for manual provisioning of Intergrated Services Digital Network (ISDN) Primary Rate Interface (PRI).

SERVICE ORDER ACTIVITY NOTES:

  1. Simulated Facility is a software device used to simulate physical hardware facilities so as to restrict the number of incoming and/or outgoing connections which can be made. Examples of service using SFG are Wide Area Telephone Service (WATS) lines and Common Channel Signaling Arrangement (CCSA) lines terminating in a Centrex, dial 9 lines for Private Branch Exhange (PBX) service and Network Access Registers in a Centrex System.
  2. Simulated Facilities are not applicable to 3ESS or DMS-10 switches.

REFERENCES:

  1. TL1
    TR-NWT-000199, DNCT View, Keyword SFG, SFGPM
  2. EWSD
    Siemens, Stromberg-Carlson, 1090-00010  Command CR ACCESS, 0770-00010 Keyword SFGN
  3. 1AESS
    TG1 Div. 3, Sec. 2AC
  4. 5ESS
    Lucent Technologies, 235-118-257, View 7.3, Keywords SFGTYPE
  5. ATIS/0BF-ASR-009, SFG field

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - LH

Required

Alphanumeric

3

13

Element: 1

Simulated Facility Group List Identifier (1AESS, 2BESS, 5ESS)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

1

1

No

No

Data Parameters:

A-Z

Element Rules:

See FID Rule 1.

Element: 2

Simulated Facility Group Identifier (1AESS; 2BESS; 5ESS)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

4

Yes

Yes

Data Parameters:

1-20471AESS
1-1272BESS
1-20005ESS   (5E14 and Prior)
1-81915ESS   (5E15)

Element: 3

Simulated Facility Direction Identifier

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

1

1

No

No

Code Set:

CodeMeaning
OOriginating
TTerminating

Element Rules:

Required when two-way WATS Access Line terminates in a Centrex.

Element: 4

Simulated Facility Group Type (5ESS)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

6

6

No

No

Code Set:

CodeMeaning
INWATSUsed for terminating Inward Wide Area Telecommunications Service (INWATS) to a Multiline Hunt Group (MLHG) or trunk group

Element: 5

Service Feature Code (1AESS)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

2

No

No

Data Parameters:

1-99

No.

Element Combination

Series

Separator

1.

1 SP 2

No

2.

1 SP [ 2 SP 3 , SP ]

No

3.

1 SP [ 2 SP 4 , SP ]

No

4.

1 SP 2 SP 5

No


SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - FL

Required

Alphanumeric

1

11

Element: 1

Simulated Facility Group Identifier (1AESS; 2BESS; 5ESS; FETEX-150; EWSD; GTD-5 EAX)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

4

No

No

Data Parameters:

1-20471AESS, EWSD
1-1272BESS
1-20005ESS (5E14 and Prior)
1-81915ESS (5E15)
0-2047FETEX-150
1-6400GTD-5 EAX

Element: 2

Simulated Facility Direction Identifier

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

1

1

No

No

Code Set:

CodeMeaning
OOriginating
TTerminating

Element Rules:

Required when two-way WATS Access Line terminates in a Centrex.
Prohibited if Element 4 code sets of OUTWATS or INWATS are present.

Element: 3

Simulated Facility Group Type (5ESS)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

6

6

No

No

Code Set:

CodeMeaning
INWATSUsed for terminating Inward Wide Area Telecommunications Service (INWATS) to a Multiline Hunt Group (MLHG) or trunk group

Element: 4

Service Feature Code (1AESS)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

2

No

No

Data Parameters:

1-99

Element: 5

Simulated Facility Group Identifier (DMS-100)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

1

6

No

No

Element: 6

Simulated Facility Group Identifier (TL1)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

1

8

No

No

No.

Element Combination

Series

Separator

1.

1

No

2.

1 SP 2

Yes

, SP

3.

1 SP 3

Yes

, SP

4.

1 SP 4

No

5.

5

No

6.

5 SP 2

Yes

, SP

7.

6

No


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: S&E - LH

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

O

P

P

Action Codes

I

I

O

O

I,O

I,O

I,O

-

-


CRIS

CABS

Data Retention

Yes

Yes

Printed on CSR

Yes

Yes

Order Section - Position: S&E - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

O

P

P

Action Codes

I,E

I,E

O,D

O,D

I,O, C,T, D,E, M,X, R

I,O, C,T, D,E, M,X, R

I,O, C,T, R

-

-


CRIS

CABS

Data Retention

Yes

Yes

Printed on CSR

Yes

Yes




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.




iconectiv Confidential - Restricted Access

This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv.

Licensed Material - Property of iconectiv

Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv.