SPEED OF ORDER ISSUANCE MEASUREMENT

INDICATES:

Dates and times (associated with the processing of service orders) used to develop measurements for the Speed of Order Issuance Measurement Plan.

DATE:

11/6/2008

BILLING:

CRIS and CABS

APPLICATIONS:

General Purpose


SECTION - POSITION

EXAMPLES

IDENT - LH

Marketing Negotiated Order
SM   BO 10-28-2008 12P
SM   BO 10-28-2008 1230P

Order Assigned Prior to Completion
SM   BO 10-28 12P; AO 10-28 1P,
     10-28 4P
SM   BO 10-28 1230P; AO 10-28 130P,
     10-28 430P

Order with Key Sheet
SM   BO 10-28 12P; KS 10-28 3P
SM   BO 10-28 1230P; KS 10-28 330P

FID RULES/CONSTRAINTS:

  1. T and F order types prohibited for Access Service application.
  2. X action code prohibited on Access Service orders.

REFERENCES:

  1. Refer to the Speed of Order Issuance Measurement Plan for complete details.
  2. The absence of an action code infers the presence of an "I" (IN) action code. The I action code is optional on the service order.

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

IDENT - LH

Required

Alphanumeric

1

83

Element: 1

Marketing Office Indicator

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

2

2

No

No

Data Parameters:

Data characteristics are locally developed.

Element: 2

Business Office Indicator

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

2

2

No

No

Code Set:

CodeMeaning
BOMarketing negotiated order

Element Rules:

Required when an order is Marketing negotiated.

Element: 3

Assignment Office Indicator

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

2

2

No

No

Code Set:

CodeMeaning
AOOrder assigned prior to precompletion typing

Element Rules:

Required when an order is assigned prior to precompletion typing.

Element: 4

Key Sheet Indicator

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

2

2

No

No

Code Set:

CodeMeaning
KSKey Sheet prepared and forwarded to Installation

Element Rules:

Required when a Key Sheet is prepared and transmitted to Installation.

Element: 5

Month - Numeric

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

2

No

No

Data Parameters:

1-12
01-12

Element Rules:

Required when Elements 1, 2, 3 and/or 4 appear. Month must appear twice on Element 3.  The first appearance indicates when the order is forwarded to the Assignment Office.  The second appearance indicates when it is returned.

Element: 6

Day of Month

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

2

No

No

Data Parameters:

1-31
01-31

Element Rules:

Required when Element 5 appears.

Element: 7

Year of Century

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

2

2

No

No

Data Parameters:

00-99

Element Rules:

Required when prescribed by local processing.

Element: 8

Calendar Year

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

4

4

No

No

Data Parameters:

0000-9999

Element Rules:

Required when prescribed by local processing.

Element: 9

Hour of Day, 12 Hour System

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

2

No

No

Data Parameters:

1-12
01-12

Element Rules:

Required when Elements 1, 2, 3 and/or 4 appear. Hour of Day must appear twice on Element 3.  The first appearance indicates when the order is forwarded to the Assignment Office.  The second appearance indicates when it is returned.

Element: 10

Minute of Hour

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

2

2

No

No

Data Parameters:

00-59

Element: 11

Meridian Code

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

1

1

No

No

Code Set:

CodeMeaning
AAM
PPM

Element Rules:

Required when Element 8 appears.

Element: 12

Not Measured Indicator

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

1

1

No

No

Code Set:

CodeMeaning
CCompany initiated record orders, orders with "Y" or "Z" appointment code or work complete orders
SSubsequent service order issued with same application date and due date as original order
XNew PBX, HORIZON, ESSX-1, DIMENSION, Centrex installation, cutover, conversion or "Project" type orders

Element Rules:

Required when an order is to be excluded from Speed of Order Issuance Measurement.

Element: 13

Computer Down Indicator

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

1

1

No

No

Code Set:

CodeMeaning
PComputer down when order to be transmitted

Element Rules:

Required when an order cannot be transmitted due to inoperable switching systems.

No.

Element Combination

Series

Separator

1.

1 SP 5 - 6 - 7 SP 9  10  11

Yes

; SP

2.

1 SP 5 - 6 - 7 SP 9  10  11 ; SP 13

Yes

; SP

3.

1 SP 5 - 6 - 7 SP 9  11

Yes

; SP

4.

1 SP 5 - 6 - 7 SP 9  11 ; SP 13

Yes

; SP

5.

1 SP 5 - 6 - 8 SP 9  10  11

Yes

; SP

6.

1 SP 5 - 6 - 8 SP 9  10  11 ; SP 13

Yes

; SP

7.

1 SP 5 - 6 - 8 SP 9  11

Yes

; SP

8.

1 SP 5 - 6 - 8 SP 9  11 ; SP 13

Yes

; SP

9.

1 SP 5 - 6 SP 9  10  11

Yes

; SP

10.

1 SP 5 - 6 SP 9  10  11 ; SP 13

Yes

; SP

11.

1 SP 5 - 6 SP 9  11

Yes

; SP

12.

1 SP 5 - 6 SP 9  11 ; SP 13

Yes

; SP

13.

2 SP 5 - 6 - 7 SP 9  10  11

Yes

; SP

14.

2 SP 5 - 6 - 7 SP 9  10  11 ; SP 12

Yes

; SP

15.

2 SP 5 - 6 - 7 SP 9  10  11 ; SP 13

Yes

; SP

16.

2 SP 5 - 6 - 7 SP 9  11

Yes

; SP

17.

2 SP 5 - 6 - 7 SP 9  11 ; SP 12

Yes

; SP

18.

2 SP 5 - 6 - 7 SP 9  11 ; SP 13

Yes

; SP

19.

2 SP 5 - 6 - 8 SP 9  10  11

Yes

; SP

20.

2 SP 5 - 6 - 8 SP 9  10  11 ; SP 12

Yes

; SP

21.

2 SP 5 - 6 - 8 SP 9  10  11 ; SP 13

Yes

; SP

22.

2 SP 5 - 6 - 8 SP 9  11

Yes

; SP

23.

2 SP 5 - 6 - 8 SP 9  11 ; SP 12

Yes

; SP

24.

2 SP 5 - 6 - 8 SP 9  11 ; SP 13

Yes

; SP

25.

2 SP 5 - 6 SP 9  10  11

Yes

; SP

26.

2 SP 5 - 6 SP 9  10  11 ; SP 12

Yes

; SP

27.

2 SP 5 - 6 SP 9  10  11 ; SP 13

Yes

; SP

28.

2 SP 5 - 6 SP 9  11

Yes

; SP

29.

2 SP 5 - 6 SP 9  11 ; SP 12

Yes

; SP

30.

2 SP 5 - 6 SP 9  11 ; SP 13

Yes

; SP

31.

3 SP 5 - 6 - 7 SP 9  10  11 , SP 5 - 6 - 7 SP 9  10  11 ; SP 13

No

32.

3 SP 5 - 6 - 7 SP 9  11 , SP 5 - 6 - 7 SP 9  11 ; SP 13

No

33.

3 SP 5 - 6 - 8 SP 9  10  11 , SP 5 - 6 - 7 SP 9  10  11 ; SP 13

No

34.

3 SP 5 - 6 - 8 SP 9  11 , SP 5 - 6 - 7 SP 9  11 ; SP 13

No

35.

3 SP 5 - 6 SP 9  10  11 , SP 5 - 6 - 7 SP 9  10  11

No

36.

3 SP 5 - 6 SP 9  10  11 , SP 5 - 6 - 8 SP 9  10  11

No

37.

3 SP 5 - 6 SP 9  10  11 , SP 5 - 6 SP 9  10  11

No

38.

3 SP 5 - 6 SP 9  10  11 , SP 5 - 6 SP 9  10  11 ; SP 13

No

39.

3 SP 5 - 6 SP 9  11 , SP 5 - 6 - 7 SP 9  11

No

40.

3 SP 5 - 6 SP 9  11 , SP 5 - 6 - 8 SP 9  11

No

41.

3 SP 5 - 6 SP 9  11 , SP 5 - 6 SP 9  11

No

42.

3 SP 5 - 6 SP 9  11 , SP 5 - 6 SP 9  11 ; SP 13

No

43.

4 SP 5 - 6 - 7 SP 9  10  11

No

44.

4 SP 5 - 6 - 7 SP 9  11

No

45.

4 SP 5 - 6 - 8 SP 9  10  11

No

46.

4 SP 5 - 6 - 8 SP 9  11

No

47.

4 SP 5 - 6 SP 9  10  11

No

48.

4 SP 5 - 6 SP 9  11

No

49.

12

No

50.

12 SP 2 SP 5 - 6 - 7 SP 9  10  11

No

51.

12 SP 2 SP 5 - 6 - 7 SP 9  11

No

52.

12 SP 2 SP 5 - 6 - 8 SP 9  10  11

No

53.

12 SP 2 SP 5 - 6 - 8 SP 9  11

No

54.

12 SP 2 SP 5 - 6 SP 9  10  11

No

55.

12 SP 2 SP 5 - 6 SP 9  11

No

56.

13

No


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: IDENT - LH

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

P

O

P

Action Codes

I

I

I

I

I

I

-

I

-


CRIS

CABS

Data Retention

No

No

Printed on CSR

No

No




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.




iconectiv Confidential - Restricted Access

This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv.

Licensed Material - Property of iconectiv

Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv.