SRS

SIMULTANEOUS RING SERVICE

INDICATES:

The telephone number to be used to access an AIN-based Simultaneous Ring Service arrangement.

DATE:

10/31/2014

BILLING:

CRIS

APPLICATIONS:

Advanced Intelligent Network (AIN), Personal Communications Service, Service Management System (SMS)


SECTION - POSITION

EXAMPLES

S&E - FL

I1   @@E/TN 210-4444/SRS 513 668-1100

SERVICE ORDER ACTIVITY NOTES:

  1. The telephone number associated with Simultaneous Ring Service which, when dialed, activates simultaneous ringing of up to three pre-defined numbers (e.g., the customer's cell phone number, the customer's business phone number, etc.). For specification of such pre-defined phone numbers, see also the SRSN FID.
  2. The Simultaneous Ring Service telephone number, though dialable, provides access to AIN services and is therefore not a traditional line-assignable customer telephone number.

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - FL

Required

Numeric

8

12

Element: 1

Numbering Plan Area Code

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

3

3

No

No

Reference:

See iconectiv LERG Routing Guide for complete list.

Element Rules:

NPA is required when it cannot be derived first from the NPA previously entered on the same logical line, second from the fielded TN, or third from the fielded EX in the Identification section.

Element: 2

Central Office Code

Appearance

Mode

Min

Max

Series

Range

Required

Numeric

3

3

No

No

Reference:

See iconectiv LERG Routing Guide for complete list.

Element: 3

Line Number

Appearance

Mode

Min

Max

Series

Range

Required

Numeric

4

4

No

No

Data Parameters:

0000-9999

No.

Element Combination

Series

Separator

1.

1 SP 2 - 3

No

2.

2 - 3

No


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: S&E - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

O

P

P

Action Codes

I,E

I,E

O,D

O,D

I,O, C,T, D,E, M,X, R

I,O, C,T, D,E, M,X, R

I,O, C,T, R

-

-


CRIS

CABS

Data Retention

Yes

No

Printed on CSR

Yes

No




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.




iconectiv Confidential - Restricted Access

This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv.

Licensed Material - Property of iconectiv

Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv.