STPH |
SIGNALING TRANSFER POINT CODE - HUB |
INDICATES: |
A point code and CLLI code identifying the Hub provider's Signaling Transfer Point(s) in a Common Channel Signaling network. |
DATE: |
11/24/2004 |
BILLING: |
CABS |
APPLICATIONS: |
Access Service, Common Channel Signaling (CCS) |
SECTION - POSITION |
EXAMPLES |
S&E - FL |
|
IG2 TSC AC123457/QM ZQA2/TTD DF52IE |
SECTION - POSITION |
APPEARANCE |
MODE |
MIN |
MAX |
S&E - FL |
Required |
Alphanumeric |
11 |
23 |
Element: 1 |
Region Network Identifier |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Required |
Numeric |
3 |
3 |
No |
No |
Data Parameters: |
||
|
Element: 2 |
LATA Network Cluster Identifier |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Required |
Numeric |
3 |
3 |
No |
No |
Data Parameters: |
||
|
Element: 3 |
End Office Cluster Member Identifier |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Required |
Numeric |
3 |
3 |
No |
No |
Data Parameters: |
||
|
Element: 4 |
COMMON LANGUAGE Geographical Code |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphanumeric |
4 |
4 |
No |
No |
Data Parameters: |
||
|
Symbols: |
Space |
Reference: |
See BR 795-100-100 for more information on CLLI codes or go to www.commonlanguage.com/clli. |
Element Rules: |
||
|
Element: 5 |
COMMON LANGUAGE Geopolitical Code |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphabetic |
2 |
2 |
No |
No |
Reference: |
See BR 795-100-100 for more information on CLLI codes or go to www.commonlanguage.com/clli. |
Element Rules: |
Required as specified in BR 795-100-100. |
Element: 6 |
CLLI Network Site Code |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphabetic or Numeric |
2 |
2 |
No |
No |
Reference: |
See BR 795-100-100 for more information on CLLI codes or go to www.commonlanguage.com/clli. |
Element Rules: |
Required as specified in BR 795-100-100. |
Element: 7 |
CLLI Network Entity Code |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphanumeric |
3 |
3 |
No |
No |
Reference: |
See BR 795-100-100 for more information on CLLI codes or go to www.commonlanguage.com/clli. |
Element Rules: |
Required as specified in BR 795-100-100. |
No. |
Element Combination |
Series |
Separator |
1. |
1 - 2 - 3 |
Yes |
, |
2. |
1 - 2 - 3 , 4 5 6 7 |
No |
ORDER TYPE/ACTION CODE/FID RELATIONSHIPS |
Order Section - Position: S&E - FL
|
Order Type |
N |
T |
F |
D |
C |
R |
X |
P |
A |
Presence |
O |
P |
P |
O |
O |
O |
P |
P |
P |
Action Codes |
I |
- |
- |
O |
I,O, C,T |
I,O, C,T |
- |
- |
- |
CRIS |
CABS |
|
Data Retention |
No |
Yes |
Printed on CSR |
No |
Yes |
Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure. |
iconectiv Confidential - Restricted Access This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv. |
Licensed Material - Property of iconectiv Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv. |