TDDW

TIME OF DAY AND DAY OF WEEK ROUTING

INDICATES:

The time and day information needed to route calls via an AIN routing service.

DATE:

10/31/2014

BILLING:

CRIS

APPLICATIONS:

Advanced Intelligent Network (AIN)


SECTION - POSITION

EXAMPLES

S&E - FL

I1   @@A/TN 555-6387/TDDW M-F 1P-9:30P,
     908 555-3024


SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - FL

Required

Alphanumeric

12

33

Element: 1

Day of Week Code

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

1

2

Yes

Yes

Code Set:

CodeMeaning
MMonday
TTuesday
WWednesday
THThursday
FFriday
SASaturday
SUSunday

Element: 2

Hour of Day, 12 Hour System (Start Time)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

2

No

No

Data Parameters:

1-12
01-12

Element: 3

Minutes of Hour (Start Time)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

2

2

No

No

Data Parameters:

00, 15, 30, 45

Element: 4

Meridian Code (Start Time)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

1

1

No

No

Code Set:

CodeMeaning
AAM
PPM

Element: 5

Hour of Day, 12 Hour System (End Time)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

2

No

No

Data Parameters:

1-12
01-12

Element: 6

Minutes of Hour (End Time)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

2

2

No

No

Data Parameters:

00, 15, 30, 45

Element: 7

Meridian Code (End Time)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

1

1

No

No

Code Set:

CodeMeaning
AAM
PPM

Element: 8

Percent of Distribution

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

3

No

No

Data Parameters:

1-100

Element Rules:

If element 8 does not appear, the default value is 100.

Element: 9

Numbering Plan Area Code

Appearance

Mode

Min

Max

Series

Range

Required

Numeric

3

3

No

No

Reference:

See iconectiv LERG Routing Guide for complete list.

Element: 10

Central Office Code

Appearance

Mode

Min

Max

Series

Range

Required

Numeric

3

3

No

No

Reference:

See iconectiv LERG Routing Guide for complete list.

Element: 11

Line Number

Appearance

Mode

Min

Max

Series

Range

Required

Numeric

4

4

No

No

Data Parameters:

0000-9999

No.

Element Combination

Series

Separator

1.

1 SP 2 : 3  4 - 5 : 6  7 SP [ 8 , 9 SP 10 - 11 ; SP ]

Yes

, SP

2.

1 SP 2 : 3  4 - 5 : 6  7 , 9 SP 10 - 11

Yes

, SP

3.

1 SP 2 : 3  4 - 5  7 SP [ 8 , 9 SP 10 - 11 ; SP ]

Yes

, SP

4.

1 SP 2 : 3  4 - 5  7 , 9 SP 10 - 11

Yes

, SP

5.

1 SP 2  4 - 5 : 6  7 SP [ 8 , 9 SP 10 - 11 ; SP ]

Yes

, SP

6.

1 SP 2  4 - 5 : 6  7 , 9 SP 10 - 11

Yes

, SP

7.

1 SP 2  4 - 5  7 SP [ 8 , 9 SP 10 - 11 ; SP ]

Yes

, SP

8.

1 SP 2  4 - 5  7 SP 8 , 9 SP 10 - 11

Yes

, SP

9.

9 SP 10 - 11

No


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: S&E - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

O

P

P

Action Codes

I,E

I,E

O,D

O,D

I,O, C,T, D,E, M,X, R

I,O, C,T, D,E, M,X, R

I,O, C,T, R

-

-


CRIS

CABS

Data Retention

Yes

No

Printed on CSR

Yes

No




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.




iconectiv Confidential - Restricted Access

This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv.

Licensed Material - Property of iconectiv

Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv.