TF1-TF9

TRANSPORT FACILITY 1 THROUGH TRANSPORT FACILITY 9

INDICATES:

The physical path(s) for logical facilities for fiber in the loop.

DATE:

4/1/2004

BILLING:

CRIS and CABS

APPLICATIONS:

Broadband, Fiber, Passive Optical Network (PON)


SECTION - POSITION

EXAMPLES

ASGM - LH

One Fiber Strand
G1   TN 201 321-2001
FA   23 OAK, FACSTOWN, NJ
IOE  000-301-110/EXK 201 321
     /CUC E ES
G2   WC 201/321
IF1  /CA PG01/PR 5
     /PGS SLC5,1/CUD E ES
     /BP 1/TEC FACSNJ1A002
     /TEA 23 OAK; TIW
     /RLC FACSNJT2124
     /RLA 123 RAND
TF1  /CA NR/PR NR/OU 3
     /BP 3/TEA 123 RAND; EOX
TF2  /CA LG01/PR 2/TMED F
     /TEA 20 OAK; CDW

Two Fiber Strands
G1   TN 201 321-2001
FA   25 SOUTH, FACSTOWN, NJ
IOE  000-301-110/EXK 201 321
     /CUC E ES
G2   WC 201/321
IF1  /CA PG02/PR 7
     /PGS RNET,2/CUD E ES
     /BP 1/TEC FACSNJU2702
     /TEA 23 SOUTH; TDW
     /RLC FACSNJT2124
     /RLA 123 RAND/DCX PEX
TF1  TRAN/CA NR/PR NR/OU 5
     /BP 9/TEA 123 RAND; EOX
TF1  REC/CA NR/PR NR/OU 5
     /BP 10/TEA 123 RAND; EOX
TF2  TRAN/CA LGO2/PR 1/TMED F
     /TEA 23 SOUTH
TF2  REC/CA LGO2/PR 2/TMED F
     /TEA 23 SOUTH

FID RULES/CONSTRAINTS:

  1. This FID is entered in the Outside Plant Facilities Subset and/or Line or Station Transfer Set.
  2. T, F, and X order types prohibited for Access Service application.

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

ASGM - LH

Optional

Alphabetic

0

4

Element: 1

Pair Instruction

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

3

4

No

No

Code Set:

CodeMeaning
RECPair Used for Receiving
TRANPair Used for Transmission

Element Rules:

Required when the NPA is different from that which is derived from the EX field or, if included, from the TN field in the fielded IDENT section.


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: ASGM - LH

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

P

O

P

P

Action Codes

I

I

I,O

O

I,O

-

I,O

-

-


CRIS

CABS

Data Retention

No

No

Printed on CSR

No

No




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.




iconectiv Confidential - Restricted Access

This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv.

Licensed Material - Property of iconectiv

Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv.