TGP

TRUNK GROUP

INDICATES:

The trunk group number of a switched service trunk.

DATE:

4/10/2008

BILLING:

CRIS

APPLICATIONS:

5ESS, DMS-100, EWSD, FETEX-150, GTD-5 EAX, ISDN BRI, ISDN PRI, Local Competition, Local Service Request (LSR)


SECTION - POSITION

EXAMPLES

S&E - LH

Primary ISDN  -  5ESS, or DMS-100
ITGP D-680
ITGP E-681
ITGP F-682

S&E - FL

I1   @@A/TN 732 251-1000/TGP 2


            or

I10  @@A/DID 1-10/TN 1201-1219
     /RTI 85/TGP NWRKNJ02FA2

I1   @@F23/CLS 10.IPZX.123456..NJ
     /TGP D-F

I15  @@A+D/DID 1-15/TGP 681
     /TLI 732 555-2000

FID RULES/CONSTRAINTS:

  1. This FID is redundant with CABS only Trunk Group Number (TGN) FID.
  2. DMS-100 Non Integrated Services Digital Network (ISDN) Trunks
    Section:  S&E      Position:  FL

    The TGP FID is required on assignable line USOC logical line when Route Index (RTI) and Direct Inward Dial (DID) FIDs are entered on the same logical line.
  3. Non-ISDN Trunks or ISDN Primary Rate Interface (PRI) Services
    Section:  S&E      Position:  FL

    The allowable element combinations are Element 2 or Elements 3 through 6.
  4. ISDN PRI Digital Subscriber Line (DSL)
    Section:  S&E      Position:  LH

    The allowable element combinations are Elements 1 and 2 or Elements 1 and Elements 3-6.
  5. ISDN PRI DSL
    The TGP FID appears as a left hand entry with additional FIDs (that define additional attributes of the trunk group) floated in any order on the same logical line.
  6. ISDN PRI DSL
    For every left hand appearance of the FID, there must be at least one corresponding floated entry of the FID with the Trunk Group Identifier (Element 1) on a DSL USOC logical line.
  7. GTD-5 EAX
    FID is used for manual provisioning of ISDN PRI.

SERVICE ORDER ACTIVITY NOTES:

  1. 5ESS
    The Trunk Group Number parameter identifies the access trunk group number (1-2000) within a switching entity.  Trunk Groups monitored by the Engineering Administration Data Acquisition System/Network Manager (EADAS/NM) system, must be less than 1024 (1-1023).

REFERENCES:

  1. 5ESS
    Lucent Technologies, 235-118-257, View 5.1, Keyword TGN
  2. EWSD
    Siemens 0770-00010, TGNO
  3. ATIS/OBF-LSR-081 and 099, TGN field

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - LH

Required

Alphanumeric

3

15

Element: 1

Alphabetic Identifier 1-3 Characters

Appearance

Mode

Min

Max

Series

Range

Required

Alphabetic

1

3

No

No

Data Parameters:

A-ZZZ

Element: 2

Trunk Group Number

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

4

No

No

Data Parameters:

0000-9999EWSD
1-8191FETEX-150
0-1023Other Switches
1-20005ESS
1-6000GTD-5 EAX

Element: 3

COMMON LANGUAGE Geographical Code (DMS-100)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

4

4

No

No

Data Parameters:

A-Z

Symbols:

Space

Reference:

See BR 795-100-100 for more information on CLLI codes or go to www.commonlanguage.com/clli.

Element Rules:

Geographical Codes created after 11/8/95 must be 4 alpha characters.

Geographical Codes created prior to 11/8/95 were two to four alpha characters.  Two or 3 character codes were left justified and the unused (right most) positions were blank filled.  It is for the latter reason that use of the "space" text symbol is permitted and, as a result, the element mode must be shown as "AN".

The actual numeric character values of 0 through 9 are not, nor have they ever been, allowed within the Geographical Code.
Required as specified in BR 795-100-100.

Element: 4

COMMON LANGUAGE Geopolitical Code (DMS-100)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

2

2

No

No

Reference:

See BR 795-100-100 for more information on CLLI codes or go to www.commonlanguage.com/clli.

Element Rules:

Required as specified in BR 795-100-100.

Element: 5

CLLI Network Site Code (DMS-100)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic or Numeric

2

2

No

No

Reference:

See BR 795-100-100 for more information on CLLI codes or go to www.commonlanguage.com/clli.

Element Rules:

Required as specified in BR 795-100-100.

Element: 6

CLLI Network Entity Code (DMS-100)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

3

3

No

No

Reference:

See BR 795-100-100 for more information on CLLI codes or go to www.commonlanguage.com/clli.

Element Rules:

Required as specified in BR 795-100-100.

No.

Element Combination

Series

Separator

1.

1 - 2

No

2.

1 - 3  4  5  6

No


SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - FL

Required

Alphanumeric

1

11

Element: 1

Alphabetic Identifier 1-3 Characters

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

1

3

Yes

Yes

Data Parameters:

A-ZZZ

Element: 2

Trunk Group Number

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

4

No

No

Data Parameters:

0000-9999EWSD
1-8191FETEX-150
0-1023Other Switches
1-20005ESS
1-6000GTD-5 EAX

Element: 3

COMMON LANGUAGE Geographical Code (DMS-100)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

4

4

No

No

Data Parameters:

A-Z

Symbols:

Space

Reference:

See BR 795-100-100 for more information on CLLI codes or go to www.commonlanguage.com/clli.

Element Rules:

Geographical Codes created after 11/8/95 must be 4 alpha characters.

Geographical Codes created prior to 11/8/95 were two to four alpha characters.  Two or 3 character codes were left justified and the unused (right most) positions were blank filled.  It is for the latter reason that use of the "space" text symbol is permitted and, as a result, the element mode must be shown as "AN".

The actual numeric character values of 0 through 9 are not, nor have they ever been, allowed within the Geographical Code.
Required as specified in BR 795-100-100.

Element: 4

COMMON LANGUAGE Geopolitical Code (DMS-100)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

2

2

No

No

Reference:

See BR 795-100-100 for more information on CLLI codes or go to www.commonlanguage.com/clli.

Element Rules:

Required as specified in BR 795-100-100.

Element: 5

CLLI Network Site Code (DMS-100)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic or Numeric

2

2

No

No

Reference:

See BR 795-100-100 for more information on CLLI codes or go to www.commonlanguage.com/clli.

Element Rules:

Required as specified in BR 795-100-100.

Element: 6

CLLI Network Entity Code (DMS-100)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

3

3

No

No

Reference:

See BR 795-100-100 for more information on CLLI codes or go to www.commonlanguage.com/clli.

Element Rules:

Required as specified in BR 795-100-100.

No.

Element Combination

Series

Separator

1.

1

Yes

, SP

2.

2

No

3.

3  4  5  6

No


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: S&E - LH

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

O

P

P

Action Codes

I

I

O

O

I,O, C,T

I,O, C,T

I,O, C,T

-

-


CRIS

CABS

Data Retention

Yes

No

Printed on CSR

Yes

No

Order Section - Position: S&E - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

O

P

P

Action Codes

I

I

O

O

I,O, C,T, D,E, R,M, X

I,O, C,T, D,E, R

I,O, C,T, R

-

-


CRIS

CABS

Data Retention

Yes

No

Printed on CSR

Yes

No




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.




iconectiv Confidential - Restricted Access

This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv.

Licensed Material - Property of iconectiv

Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv.