TTMR

X.75 TIMERS

INDICATES:

The X.75 (Interexchange Packet Interface) packet level timers (T Timer) for virtual call setup, resetting and clearing.

DATE:

2/7/1992

BILLING:

CRIS and CABS

APPLICATIONS:

Access Service


SECTION - POSITION

EXAMPLES

S&E - FL

I1   @@C/TTMR T30 10; T31 12;
     T32 20; T33 6

REFERENCES:

  1. Refer to TR-NPL-000065 (Interexchange Packet Interface) for additional information.
  2. Northern Telecom Practice 241-2001-321, page 454.

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - FL

Required

Alphanumeric

5

7

Element: 1

Timer Indicator

Appearance

Mode

Min

Max

Series

Range

Required

Alphanumeric

3

3

No

No

Code Set:

CodeMeaning
T30Restart Timer
T31Setup Timer
T32Reset Timer
T33Clear Timer

Element: 2

Timer Value

Appearance

Mode

Min

Max

Series

Range

Required

Numeric

1

3

No

No

Element Rules:

Timer values may be indicated in seconds or ticks (1 tick = x seconds).

No.

Element Combination

Series

Separator

1.

1 SP 2

4

; SP


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: S&E - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

P

P

O

O

O

O

P

P

Action Codes

I,E

-

-

O,D

I,O, C,T, D,E, M,X, R

I,O, C,T, D,E, M,X, R

C,T, R

-

-


CRIS

CABS

Data Retention

Yes

Yes

Printed on CSR

Yes

Yes




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.




iconectiv Confidential - Restricted Access

This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv.

Licensed Material - Property of iconectiv

Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv.