UCP1-UCP6

UNBUNDLED CONNECTION POINT 1 THRU 6

INDICATES:

The connection point characteristics of the unbundled portion of a subscriber's service.

DATE:

10/31/2014

BILLING:

CRIS and CABS

APPLICATIONS:

Digital Subscriber Line (DSL), Local Competition


SECTION - POSITION

EXAMPLES

S&E - FL

I1    @@A/TN 732 555-1234/PIC ATX
      /UNE1 .LGGS.123456..NJ
      /UNN1 SPC.1623/UCP1 TYP.VI,
      LOC.CO, MTPT CA.24AZC,
      PR.1542, SMSC.1

I1    @@A/TN 732 555-1234/PIC ABC
      /UNE1 .LGGS.123456..NJ
      /UNN1 SPC.1623/UCP1 TYP.UL,
      LOC.CO, MTPT CFA.ABC01 26-NL
      44 PSWYNJAA PSWYNJAAH11

ASGM - FL

      /UCP1 LOC.VR, MTPT CA.24AZC,
      PR.1542

FID RULES/CONSTRAINTS:

  1. T, F, and X order types prohibited for Access Service application.
  2. X action code prohibited on Access Service orders.
  3. Section:  ASGM  Position:  FL
    This FID is entered in the Central Office Facilities Subset and/or the Outside Plant Facilities Subset.
  4. Element Combinations 7 through 87 are COMMON LANGUAGE compliant in accordance with BR 795-450-100, Section 6, CLFI Code Application Formats, but are not supported by Telcordia and/or Ericsson Operations Support Systems (OSSs).

SERVICE ORDER ACTIVITY NOTES:

  1. This FID is used to specify the details of the cross connection between multiple service providers on unbundled services.
  2. The number contained in the UCP1-UCP6 FID must match the number contained in the Unbundled Network Element Circuit Identification 1 thru 6 (UNE1-UNE6) and Unbundled Network Customer Name 1 thru 6 (UNN1-UNN6) FIDs, i.e., UCP1 is related to UNE1 and UNN1, UCP2 is related to UNE2 and UNN2, etc..
  3. This FID is used in the Assignment Section to support ADSL.

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - FL

Required

Alphanumeric

14

63

Element: 1

Type of Unbundled Service Name

Appearance

Mode

Min

Max

Series

Range

Required

Alphabetic

3

3

No

No

Code Set:

CodeMeaning
TYPUnbundled Service Type

Element: 2

Type of Unbundled Service Value

Appearance

Mode

Min

Max

Series

Range

Required

Alphabetic

2

2

No

No

Code Set:

CodeMeaning
VILine Sharing-Voice
DALine Sharing-Data
ULUnbundled Loop
USUnbundled Switchport

Element: 3

Location Name

Appearance

Mode

Min

Max

Series

Range

Required

Alphabetic

3

3

No

No

Code Set:

CodeMeaning
LOCLocation

Element: 4

Location Value

Appearance

Mode

Min

Max

Series

Range

Required

Alphabetic

2

3

No

No

Code Set:

CodeMeaning
CCPCentral Office meetpoint modeled as a Cable/Pair at CLEC cage
COCollocated with switching facilities in a central office or a remote distribution frame
FLDNo collocated switching facilities
VRVirtual meetpoint logical connection data

Element Rules:

When Element 4 Code Set is FLD, Elements 5, 6, 7, 8, and 9 are required.
When Element 4 Code Set is CCP, it must be associated with a CKL.
When Element 4 Code Set is CO, either Element 10 or Element 14 is required.

Element: 5

Meet Point Name

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

4

4

No

No

Code Set:

CodeMeaning
MTPTMeetpoint

Element: 6

Cable Name

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

2

2

No

No

Code Set:

CodeMeaning
CACable Number

Element: 7

Cable Value

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

1

10

2

No

Symbols:

Hyphen

Element Rules:

Series entry is used when a four-wire assignment is needed.
Series entry is not allowed when Element 2 Code Set is VI or DA.

Element: 8

Pair Name

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

2

2

No

No

Code Set:

CodeMeaning
PRPair Number

Element: 9

Pair Value

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

1

4

2

No

Element Rules:

Series entry is used when a four-wire assignment is needed.
Series entry is not allowed when Element 2 Code Set is VI or DA.

Element: 10

Equipment Name

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

3

3

No

No

Code Set:

CodeMeaning
EQPEquipment Name

Element: 11

Equipment Value

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

1

24

No

No

Symbols:

Ampersand, Apostrophe, Asterisk, At Sign, Cent Sign, Colon, Comma, Dollar Sign, Hyphen, Left Double Quote, Left Parenthesis, Left Single Quote, Number Sign, Period, Plus Sign, Right Double Quote, Right Parenthesis, Right Single Quote

Element: 12

Spectrum Management Service Class Name

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

4

4

No

No

Code Set:

CodeMeaning
SMSCSpectrum Management Service Class

Element: 13

Spectrum Management Service Class Value

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

1

No

No

Data Parameters:

1-9

Element: 14

Connecting Facility Assignment

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

3

3

No

No

Code Set:

CodeMeaning
CFAConnecting Facility Assignment

Element: 15

CLFI Transmission Facility Designation Code

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

1

5

No

No

Reference:

See BR 795-450-100 for complete list.

Element: 16

CLFI Transmission Facility Type Code

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

1

6

No

No

Reference:

See BR 795-450-100 for complete list.

Element: 17

CLFI Channel/Pair Code

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

1

5

Yes

Yes

Reference:

See BR 795-450-100 for complete list.

Element: 18

Cable Name

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

1

6

No

No

Element: 19

Cable Gauge

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

2

2

No

No

Element: 20

Cable Loading Indicator

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

1

2

No

No

Code Set:

CodeMeaning
LLoaded
NLNot Loaded

Element: 21

Cable Pair

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

1

5

Yes

Yes

Element: 22

COMMON LANGUAGE Geographical Code (A Location)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

4

4

No

No

Data Parameters:

A-Z

Symbols:

Space

Reference:

See BR 795-100-100 for more information on CLLI codes or go to www.commonlanguage.com/clli.

Element Rules:

Geographical Codes created after 11/8/95 must be 4 alpha characters.

Geographical Codes created prior to 11/8/95 were two to four alpha characters.  Two or 3 character codes were left justified and the unused (rightmost) positions were blank filled.  It is for the latter reason that use of the "space" text symbol is permitted and, as a result, the element mode must be shown as "AN".

The actual numeric character values of 0 through 9 are not, nor have they ever been, allowed within the Geographical Code.
Required as specified in BR 795-100-100.

Element: 23

COMMON LANGUAGE Geopolitical Code (A Location)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

2

2

No

No

Reference:

See BR 795-100-100 for more information on CLLI codes or go to www.commonlanguage.com/clli.

Element Rules:

Required as specified in BR 795-100-100.

Element: 24

CLLI Network Site Code (A Location)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic or Numeric

2

2

No

No

Reference:

See BR 795-100-100 for more information on CLLI codes or go to www.commonlanguage.com/clli.

Element Rules:

Required as specified in BR 795-100-100.

Element: 25

CLLI Network Entity Code (A Location)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

3

3

No

No

Reference:

See BR 795-100-100 for more information on CLLI codes or go to www.commonlanguage.com/clli.

Element Rules:

Required as specified in BR 795-100-100.

Element: 26

CLLI Network Support Site Code (A Location)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

5

5

No

No

Reference:

See BR 795-100-100 for more information on CLLI codes or go to www.commonlanguage.com/clli.

Element Rules:

Required as specified in BR 795-100-100.

Element: 27

CLLI Customer Site Code (A Location)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

5

5

No

No

Data Parameters:

Data characteristics are locally developed.

Reference:

See BR 795-100-100 for more information on CLLI codes or go to www.commonlanguage.com/clli.

Element Rules:

Required as specified in BR 795-100-100.

Element: 28

COMMON LANGUAGE Geographical Code (Z Location)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

4

4

No

No

Data Parameters:

A-Z

Symbols:

Space

Reference:

See BR 795-100-100 for more information on CLLI codes or go to www.commonlanguage.com/clli.

Element Rules:

Geographical Codes created after 11/8/95 must be 4 alpha characters.

Geographical Codes created prior to 11/8/95 were two to four alpha characters.  Two or 3 character codes were left justified and the unused (rightmost) positions were blank filled.  It is for the latter reason that use of the "space" text symbol is permitted and, as a result, the element mode must be shown as "AN".

The actual numeric character values of 0 through 9 are not, nor have they ever been, allowed within the Geographical Code.
Required as specified in 795-100-100.

Element: 29

COMMON LANGUAGE Geopolitical Code (Z Location)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

2

2

No

No

Reference:

See BR 795-100-100 for more information on CLLI codes or go to www.commonlanguage.com/clli.

Element Rules:

Required as specified in BR 795-100-100.

Element: 30

CLLI Network Site Code (Z Location)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic or Numeric

2

2

No

No

Reference:

See BR 795-100-100 for more information on CLLI codes or go to www.commonlanguage.com/clli.

Element Rules:

Required as specified in BR 795-100-100.

Element: 31

CLLI Network Entity Code (Z Location)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

3

3

No

No

Reference:

See BR 795-100-100 for more information on CLLI codes or go to www.commonlanguage.com/clli.

Element Rules:

Required as specified in BR 795-100-100.

Element: 32

CLLI Network Support Site Code (Z Location)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

5

5

No

No

Reference:

See BR 795-100-100 for more information on CLLI codes or go to www.commonlanguage.com/clli.

Element Rules:

Required as specified in BR 795-100-100.

Element: 33

CLLI Customer Site Code (Z Location)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

5

5

No

No

Reference:

See BR 795-100-100 for more information on CLLI codes or go to www.commonlanguage.com/clli.

Element Rules:

Required as specified in BR 795-100-100.

No.

Element Combination

Series

Separator

1.

1 . 2 , SP 3 . 4

No

2.

1 . 2 , SP 3 . 4 , SP 5 SP 6 . 7 , SP 8 . 9

No

3.

1 . 2 , SP 3 . 4 , SP 5 SP 6 . 7 , SP 8 . 9 , SP 12 . 13

No

4.

1 . 2 , SP 3 . 4 , SP 5 SP 10 . 11

No

5.

1 . 2 , SP 3 . 4 , SP 5 SP 10 . 11 , SP 12 . 13

No

6.

1 . 2 , SP 3 . 4 , SP 12 . 13

No

7.

1 . 2 , SP 3 . 4 , SP 14 . 15 SP 16 SP 17 SP 22  23  24  25 SP 28  29  30

No

8.

1 . 2 , SP 3 . 4 , SP 14 . 15 SP 16 SP 17 SP 22  23  24  25 SP 28  29  30  31

No

9.

1 . 2 , SP 3 . 4 , SP 14 . 15 SP 16 SP 17 SP 22  23  24  25 SP 28  29  32

No

10.

1 . 2 , SP 3 . 4 , SP 14 . 15 SP 16 SP 17 SP 22  23  24  25 SP 28  29  33

No

11.

1 . 2 , SP 3 . 4 , SP 14 . 15 SP 16 SP 17 SP 22  23  24 SP 28  29  30

No

12.

1 . 2 , SP 3 . 4 , SP 14 . 15 SP 16 SP 17 SP 22  23  24 SP 28  29  30  31

No

13.

1 . 2 , SP 3 . 4 , SP 14 . 15 SP 16 SP 17 SP 22  23  24 SP 28  29  32

No

14.

1 . 2 , SP 3 . 4 , SP 14 . 15 SP 16 SP 17 SP 22  23  24 SP 28  29  33

No

15.

1 . 2 , SP 3 . 4 , SP 14 . 15 SP 16 SP 17 SP 22  23  26 SP 28  29  30

No

16.

1 . 2 , SP 3 . 4 , SP 14 . 15 SP 16 SP 17 SP 22  23  26 SP 28  29  30  31

No

17.

1 . 2 , SP 3 . 4 , SP 14 . 15 SP 16 SP 17 SP 22  23  26 SP 28  29  32

No

18.

1 . 2 , SP 3 . 4 , SP 14 . 15 SP 16 SP 17 SP 22  23  26 SP 28  29  33

No

19.

1 . 2 , SP 3 . 4 , SP 14 . 15 SP 16 SP 17 SP 22  23  27 SP 28  29  30

No

20.

1 . 2 , SP 3 . 4 , SP 14 . 15 SP 16 SP 17 SP 22  23  27 SP 28  29  30  31

No

21.

1 . 2 , SP 3 . 4 , SP 14 . 15 SP 16 SP 17 SP 22  23  27 SP 28  29  32

No

22.

1 . 2 , SP 3 . 4 , SP 14 . 15 SP 16 SP 17 SP 22  23  27 SP 28  29  33

No

23.

1 . 2 , SP 3 . 4 , SP 14 . 15 SP 16 SP 22  23  24  25 SP 28  29  30

No

24.

1 . 2 , SP 3 . 4 , SP 14 . 15 SP 16 SP 22  23  24  25 SP 28  29  30  31

No

25.

1 . 2 , SP 3 . 4 , SP 14 . 15 SP 16 SP 22  23  24  25 SP 28  29  32

No

26.

1 . 2 , SP 3 . 4 , SP 14 . 15 SP 16 SP 22  23  24  25 SP 28  29  33

No

27.

1 . 2 , SP 3 . 4 , SP 14 . 15 SP 16 SP 22  23  24 SP 28  29  30

No

28.

1 . 2 , SP 3 . 4 , SP 14 . 15 SP 16 SP 22  23  24 SP 28  29  30  31

No

29.

1 . 2 , SP 3 . 4 , SP 14 . 15 SP 16 SP 22  23  24 SP 28  29  32

No

30.

1 . 2 , SP 3 . 4 , SP 14 . 15 SP 16 SP 22  23  24 SP 28  29  33

No

31.

1 . 2 , SP 3 . 4 , SP 14 . 15 SP 16 SP 22  23  26 SP 28  29  30

No

32.

1 . 2 , SP 3 . 4 , SP 14 . 15 SP 16 SP 22  23  26 SP 28  29  30  31

No

33.

1 . 2 , SP 3 . 4 , SP 14 . 15 SP 16 SP 22  23  26 SP 28  29  32

No

34.

1 . 2 , SP 3 . 4 , SP 14 . 15 SP 16 SP 22  23  26 SP 28  29  33

No

35.

1 . 2 , SP 3 . 4 , SP 14 . 15 SP 16 SP 22  23  27 SP 28  29  30

No

36.

1 . 2 , SP 3 . 4 , SP 14 . 15 SP 16 SP 22  23  27 SP 28  29  30  31

No

37.

1 . 2 , SP 3 . 4 , SP 14 . 15 SP 16 SP 22  23  27 SP 28  29  32

No

38.

1 . 2 , SP 3 . 4 , SP 14 . 15 SP 16 SP 22  23  27 SP 28  29  33

No

39.

1 . 2 , SP 3 . 4 , SP 14 . 15 SP 17 SP 22  23  24  25 SP 28 SP 29  30

No

40.

1 . 2 , SP 3 . 4 , SP 14 . 15 SP 17 SP 22  23  24  25 SP 28 SP 29  30  31

No

41.

1 . 2 , SP 3 . 4 , SP 14 . 15 SP 17 SP 22  23  24  25 SP 28 SP 29  32

No

42.

1 . 2 , SP 3 . 4 , SP 14 . 15 SP 17 SP 22  23  24  25 SP 28 SP 29  33

No

43.

1 . 2 , SP 3 . 4 , SP 14 . 15 SP 17 SP 22  23  24 SP 28  29  30

No

44.

1 . 2 , SP 3 . 4 , SP 14 . 15 SP 17 SP 22  23  24 SP 28  29  30  31

No

45.

1 . 2 , SP 3 . 4 , SP 14 . 15 SP 17 SP 22  23  24 SP 28  29  32

No

46.

1 . 2 , SP 3 . 4 , SP 14 . 15 SP 17 SP 22  23  24 SP 28  29  33

No

47.

1 . 2 , SP 3 . 4 , SP 14 . 15 SP 17 SP 22  23  26 SP 28  29  30

No

48.

1 . 2 , SP 3 . 4 , SP 14 . 15 SP 17 SP 22  23  26 SP 28  29  30  31

No

49.

1 . 2 , SP 3 . 4 , SP 14 . 15 SP 17 SP 22  23  26 SP 28  29  32

No

50.

1 . 2 , SP 3 . 4 , SP 14 . 15 SP 17 SP 22  23  26 SP 28  29  33

No

51.

1 . 2 , SP 3 . 4 , SP 14 . 15 SP 17 SP 22  23  27 SP 28  29  30

No

52.

1 . 2 , SP 3 . 4 , SP 14 . 15 SP 17 SP 22  23  27 SP 28  29  30  31

No

53.

1 . 2 , SP 3 . 4 , SP 14 . 15 SP 17 SP 22  23  27 SP 28  29  32

No

54.

1 . 2 , SP 3 . 4 , SP 14 . 15 SP 17 SP 22  23  27 SP 28  29  33

No

55.

1 . 2 , SP 3 . 4 , SP 14 . 15 SP 22  23  24  25 SP 28  29  30

No

56.

1 . 2 , SP 3 . 4 , SP 14 . 15 SP 22  23  24  25 SP 28  29  30  31

No

57.

1 . 2 , SP 3 . 4 , SP 14 . 15 SP 22  23  24  25 SP 28  29  32

No

58.

1 . 2 , SP 3 . 4 , SP 14 . 15 SP 22  23  24  25 SP 28  29  33

No

59.

1 . 2 , SP 3 . 4 , SP 14 . 15 SP 22  23  24 SP 28  29  30

No

60.

1 . 2 , SP 3 . 4 , SP 14 . 15 SP 22  23  24 SP 28  29  30  31

No

61.

1 . 2 , SP 3 . 4 , SP 14 . 15 SP 22  23  24 SP 28  29  32

No

62.

1 . 2 , SP 3 . 4 , SP 14 . 15 SP 22  23  24 SP 28  29  33

No

63.

1 . 2 , SP 3 . 4 , SP 14 . 15 SP 22  23  26 SP 28  29  30

No

64.

1 . 2 , SP 3 . 4 , SP 14 . 15 SP 22  23  26 SP 28  29  30  31

No

65.

1 . 2 , SP 3 . 4 , SP 14 . 15 SP 22  23  26 SP 28  29  30  31

No

66.

1 . 2 , SP 3 . 4 , SP 14 . 15 SP 22  23  26 SP 28  29  32

No

67.

1 . 2 , SP 3 . 4 , SP 14 . 15 SP 22  23  27 SP 28  29  30

No

68.

1 . 2 , SP 3 . 4 , SP 14 . 15 SP 22  23  27 SP 28  29  30  31

No

69.

1 . 2 , SP 3 . 4 , SP 14 . 15 SP 22  23  27 SP 28  29  32

No

70.

1 . 2 , SP 3 . 4 , SP 14 . 15 SP 22  23  27 SP 28  29  33

No

71.

1 . 2 , SP 3 . 4 , SP 14 . 15 SP 22  23  27 SP 28  29  33

No

72.

1 . 2 , SP 3 . 4 , SP 14 . 18 SP 19 - 20 SP 21 SP 22  23  24  25 SP 28  29  30

No

73.

1 . 2 , SP 3 . 4 , SP 14 . 18 SP 19 - 20 SP 21 SP 22  23  24  25 SP 28  29  30  31

No

74.

1 . 2 , SP 3 . 4 , SP 14 . 18 SP 19 - 20 SP 21 SP 22  23  24  25 SP 28  29  32

No

75.

1 . 2 , SP 3 . 4 , SP 14 . 18 SP 19 - 20 SP 21 SP 22  23  24  25 SP 28  29  33

No

76.

1 . 2 , SP 3 . 4 , SP 14 . 18 SP 19 - 20 SP 21 SP 22  23  24 SP 28  29  30

No

77.

1 . 2 , SP 3 . 4 , SP 14 . 18 SP 19 - 20 SP 21 SP 22  23  24 SP 28  29  30  31

No

78.

1 . 2 , SP 3 . 4 , SP 14 . 18 SP 19 - 20 SP 21 SP 22  23  24 SP 28  29  32

No

79.

1 . 2 , SP 3 . 4 , SP 14 . 18 SP 19 - 20 SP 21 SP 22  23  24 SP 28  29  33

No

80.

1 . 2 , SP 3 . 4 , SP 14 . 18 SP 19 - 20 SP 21 SP 22  23  26 SP 28  29  30

No

81.

1 . 2 , SP 3 . 4 , SP 14 . 18 SP 19 - 20 SP 21 SP 22  23  26 SP 28  29  30  31

No

82.

1 . 2 , SP 3 . 4 , SP 14 . 18 SP 19 - 20 SP 21 SP 22  23  26 SP 28  29  32

No

83.

1 . 2 , SP 3 . 4 , SP 14 . 18 SP 19 - 20 SP 21 SP 22  23  26 SP 28  29  33

No

84.

1 . 2 , SP 3 . 4 , SP 14 . 18 SP 19 - 20 SP 21 SP 22  23  27 SP 28  29  30

No

85.

1 . 2 , SP 3 . 4 , SP 14 . 18 SP 19 - 20 SP 21 SP 22  23  27 SP 28  29  30  31

No

86.

1 . 2 , SP 3 . 4 , SP 14 . 18 SP 19 - 20 SP 21 SP 22  23  27 SP 28  29  31

No

87.

1 . 2 , SP 3 . 4 , SP 14 . 18 SP 19 - 20 SP 21 SP 22  23  27 SP 28  29  32

No


SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

ASGM - FL

Required

Alphanumeric

18

60

Element: 1

Location Name

Appearance

Mode

Min

Max

Series

Range

Required

Alphabetic

3

3

No

No

Code Set:

CodeMeaning
LOCLocation

Element: 2

Location Value

Appearance

Mode

Min

Max

Series

Range

Required

Alphabetic

2

3

No

No

Code Set:

CodeMeaning
CCPCentral Office meetpoint modeled as a Cable/Pair at CLEC cage
COCollocated with switching facilities in a central office or a remote distribution frame
FLDNo collocated switching facilities
VRVirtual meetpoint logical connection data

Element: 3

Meet Point Name

Appearance

Mode

Min

Max

Series

Range

Required

Alphabetic

4

4

No

No

Code Set:

CodeMeaning
MTPTMeetpoint

Element: 4

Cable Name

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

2

2

No

No

Code Set:

CodeMeaning
CACable Number

Element: 5

Cable Value

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

1

10

2

No

Symbols:

Hyphen

Element Rules:

Series entry is used when a four-wire assignment is needed.

Element: 6

Pair Name

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

2

2

No

No

Code Set:

CodeMeaning
PRPair Number

Element: 7

Pair Value

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

1

4

2

No

Element Rules:

Series entry is used when a four-wire assignment is needed.

Element: 8

Equipment Name

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

3

3

No

No

Code Set:

CodeMeaning
EQPEquipment Name

Element: 9

Equipment Value

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

1

42

No

No

Symbols:

Ampersand, Apostrophe, Asterisk, At Sign, Cent Sign, Colon, Comma, Dollar Sign, Hyphen, Left Double Quote, Left Parenthesis, Left Single Quote, Number Sign, Period, Plus Sign, Right Double Quote, Right Parenthesis, Right Single Quote

No.

Element Combination

Series

Separator

1.

1 . 2 , SP 3 SP 4 . 5 , SP 6 . 7

No

2.

1 . 2 , SP 3 SP 8 . 9

No


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: S&E - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

O

P

P

Action Codes

I, E

I, E

O, D

O, D

I, O, C, T, D, E, M, X, R

I, O, C, T, D, E, M, X, R

I, O, C, T, R

-

-

Other FIDs Required Logical Line

UNE1-6 UNN1-6

UNE1-6 UNN1-6

UNE1-6 UNN1-6

UNE1-6 UNN1-6

UNE1-6 UNN1-6

UNE1-6 UNN1-6

UNE1-6 UNN1-6

-

-


CRIS

CABS

Data Retention

Yes

Yes

Printed on CSR

Yes

Yes

Order Section - Position: ASGM - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

P

O

P

P

Action Codes

I

I

O

O

I, O

-

I, O

-

-


CRIS

CABS

Data Retention

No

No

Printed on CSR

No

No




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.




iconectiv Confidential - Restricted Access

This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv.

Licensed Material - Property of iconectiv

Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv.