UN

UNIT NUMBER

INDICATES:

The unit number assigned to a piece of hardware associated with the Dialog Intercom System.

DATE:

10/31/2014

BILLING:

CRIS

APPLICATIONS:

General Purpose


SECTION - POSITION

EXAMPLES

S&E - FL

Unit number - in series with intercom station unit USOC
I1   @@A/TN 732 555-1234
I7   @@Y/TN 732 555-1234/UN 10, 14, 18, 22, 26,
     30, 34

Unit number, line numbers and dial access code with intercom line access unit USOC
I1   @@A/TN 732 555-1234
I1   @@Y/TN 732 555-1234/UN 80 234-6777 &
     81 234-6778

Unit number without associated line number and dial access code with associated line number with line access unit USOC
I1   @@A/TN 732 555-1234
I1   @@Y/TN 732 555-1234/UN 82 & 83 TER 3001
     MLG 123

FID RULES/CONSTRAINTS:

  1. This FID and its data will follow the USOCs for intercom station units, intercom line access units and off premises intercom code equipment.
  2. One or two line numbers and a dial access code (Elements 10, 14 and 20) may appear as part of any of the combinations shown in the Element Combination Chart.  Such entries will be separated by an ampersand and space.

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - FL

Required

Alphanumeric

2

38

Element: 1

Unit Number

Appearance

Mode

Min

Max

Series

Range

Required

Numeric

2

2

Yes

No

Data Parameters:

10-69, 80, 82, 84, 86

Element: 2

Line Number Indicator

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

2

3

No

No

Code Set:

CodeMeaning
CLSSpecial Service Circuit Identification in CLCI S/S Serial Number Format
PXPrivate Branch Exchange (PBX) Station Number
SISSpecial Identifying Telephone Number Supplement
SITSpecial Identifying Telephone Number
TERTerminal Number - Multiline Group
TNTelephone Number

Element Rules:

May appear only with line access unit USOC.

Element: 3

CLCI Prefix

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

1

2

No

No

Reference:

See BR-795-402-100 for complete list.

Element: 4

CLCI Service Code

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

2

2

No

No

Reference:

See BR-795-402-100 for complete list.

Element Rules:

Required when CLS is entered as a Line Number Indicator.

Element: 5

CLCI Modifier

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

2

2

No

No

Reference:

See BR-795-402-100 for complete list.

Element Rules:

Required when CLS is entered as a Line Number Indicator.

Element: 6

CLCI Serial Number

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

6

No

No

Data Parameters:

1-999999

Element Rules:

Required when CLS is entered as a Line Number Indicator.

Element: 7

CLCI Suffix

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

3

No

No

Data Parameters:

1-999

Element: 8

COMMON LANGUAGE Company Assigning Circuit Identification

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

2

4

No

No

Reference:

See BR-751-100-112 for complete list.

Element Rules:

Required when CLS is entered as a Line Number Indicator.

Element: 9

CLCI Segment Name

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

1

3

No

No

Data Parameters:

0-9
A-Z

Element: 10

PBX Station Line Number

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

4

No

No

Data Parameters:

1-9999

Element Rules:

Required when PX is entered as Line Indicator.

Element: 11

Special Identifying Telephone Number Supplement

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

4

No

No

Data Parameters:

1-9999

Element Rules:

Required when SIS or SIT is entered as a Line Number Indicator.

Element: 12

Numbering Plan Area Code

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

3

3

No

No

Reference:

See iconectiv LERG Routing Guide for complete list.

Element: 13

Central Office Code

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

3

3

No

No

Reference:

See iconectiv LERG Routing Guide for complete list.

Element: 14

Line Number

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

4

4

No

No

Data Parameters:

0000-9999

Element: 15

Terminal Number

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

4

No

No

Data Parameters:

1-2047No. 1AESS Hunting Terminals or Multiline Non-Hunt Group Terminals)
3001-3999No. 1AESS Non-Hunting Terminals
0-255No. 2ESS Non-Hunting Terminals must have numbers higher than any Hunting Terminals in the Multiline Group
0-63No. 3ESS Hunting Terminals, not applicable to Non-Hunting Terminals

Element Rules:

Required when TER is entered as a Line Indicator.

Element: 16

Multiline Non-Hunt Group Indicator

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

3

3

No

No

Code Set:

CodeMeaning
MLGMultiline Non-Hunt Group

Element Rules:

Required when multiline non-hunt group number is to be entered.

Element: 17

Multiline Non-Hunt Group Number

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

4

No

No

Data Parameters:

0-2047

Element Rules:

MLG or Hunting-Multiline Group Number (HML) are required when TER appears.
Required when Terminal Number is entered and HML does not appear.

Element: 18

Hunting Multiline Group Number Indicator

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

3

3

No

No

Code Set:

CodeMeaning
HMLHunting Multi-Line Group

Element Rules:

Required when Hunting Multiline Group Number is to be entered.

Element: 19

Hunting Multiline Group Number

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

4

No

No

Data Parameters:

1-2047No. 1AESS Hunting Terminals or Multiline Non-Hunt Group Terminals
3001-3999No. 1AESS Non-Hunting Terminals
0-255No. 2ESS Non-Hunting Terminals must have numbers higher than any Hunting Terminals in the Multiline Group)
0-63No. 3ESS Hunting Terminals, not applicable to Non-Hunting Terminals

Element Rules:

Required when Terminal Number is entered and MLG does not appear.

Element: 20

Dial Access Code

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

2

2

No

No

Data Parameters:

81, 83, 85, 87

Element Rules:

May appear only with line access unit USOC.

No.

Element Combination

Series

Separator

1.

1

Yes

, SP

2.

1 SP 2 SP 3 . 4  5 . 6 . 7 . 8 . 9 SP & 20

No

3.

1 SP 2 SP 3 . 4  5 . 6 . 7 . 8 . 20

No

4.

1 SP 2 SP 3 . 4  5 . 6 . 8 . 9 SP & 20

No

5.

1 SP 2 SP 3 . 4  5 . 6 . 8 SP & 20

No

6.

1 SP 2 . 4  5 . 6 . 7 . 8 . 9 SP & 20

No

7.

1 SP 2 . 4  5 . 6 . 7 . 8 SP & 20

No

8.

1 SP 2 . 4  5 . 6 . 8 . 9 SP & 20

No

9.

1 SP 2 . 4  5 . 6 . 8 SP & 20

No

10.

1 SP 2 SP 10 SP & 20

No

11.

1 SP 2 SP 11 SP 12 SP & 20

No

12.

1 SP 2 SP 12 SP 13 - 14 SP & 20

No

13.

1 SP 2 SP 13 - 14

No

14.

1 SP 2 SP 13 - 14 SP & 20

No

15.

1 SP 2 SP 15 SP 16 SP 17 SP & 20

No

16.

1 SP 2 SP 15 SP 18 SP 19 SP & 20

No

17.

1 SP 3 - 14

No

18.

1 SP 14

No


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: S&E - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

O

P

P

Action Codes

I,E

I,E

O,D

O,D

I,O, C,T, M,X, D,E, R

I,O, C,T, M,X, D,E, R

C,T, R

-

-


CRIS

CABS

Data Retention

Yes

No

Printed on CSR

Yes

No




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.




iconectiv Confidential - Restricted Access

This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv.

Licensed Material - Property of iconectiv

Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv.