UTIL

INTEREXCHANGE PACKET INTERFACE (X.75) UTILITY

INDICATES:

The interface negotiated between packet switching networks.

DATE:

4/16/1992

BILLING:

CRIS and CABS

APPLICATIONS:

Access Service


SECTION - POSITION

EXAMPLES

S&E - FL

I1   @@V/UTIL CLID M M I I;
     TPUT O O O O; W O O O O;
     DL O O O O; TARF C C C C;
     TRAN C O O O; CUG O O I I;
     RC M I O I; CUGO O O O O

Siemens EDX Packet Switch
I1   @@V/UTIL CLID, TPUT, TARF, RC

FID RULES/CONSTRAINTS:

  1. Each Utility Name (Element 1) must be coded with Elements 2 through 5 except when served by EDX or Bolt, Berenek, and Newman packet switches.
  2. T, F, and X order types prohibited for Access Service application.

REFERENCES:

  1. Refer to TR-NPL-000065 (Interexchange Packet Interface) and TR-TSY-000461 (X.75 Interface to BOC/IDC Networks) for additional information.

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - FL

Required

Alphabetic

1

13

Element: 1

Utility Name

Appearance

Mode

Min

Max

Series

Range

Required

Alphabetic

1

5

Yes

No

Code Set:

CodeMeaning
CLIDCall Identification
CLAMNCalled Line Address Modified Notifier
CNICClearing Network Identification Code
CUGClosed User Group
CUGOClosed User Group with Outgoing Access
DLData Length/Packet Size
FSFast Select
MARKUtility Marker
RCReverse Charge
RPOARecognized Private Operating Agency
TARFTariff
TDITransit Delay Indication
TDSTransit Delay Selection
TPUTThroughput
TRANTransit
WWindow

Element: 2

Utility Marker - Call Request From Switch

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

1

1

No

No

Code Set:

CodeMeaning
MMandatory
OOptional
IIgnore
CClear

Element Rules:

Element is not required with Siemens EDX and Bolt, Berenek, and Newman packet switches.

Element: 3

Utility Marker - Call Request To Packet Switch

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

1

1

No

No

Code Set:

CodeMeaning
MMandatory
OOptional
IIgnore
CClear

Element Rules:

Element is not required with Siemens EDX and Bolt, Berenek, and Newman packet switches.

Element: 4

Utility Marker - Call Connect From Packet Switch

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

1

1

No

No

Code Set:

CodeMeaning
MMandatory
OOptional
IIgnore
CClear

Element Rules:

Element is not required with Siemens EDX and Bolt, Berenek, and Newman packet switches.

Element: 5

Utility Marker - Call Connect To Packet Switch

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

1

1

No

No

Code Set:

CodeMeaning
MMandatory
OOptional
IIgnore
CClear

Element Rules:

Element is not required with Siemens EDX and Bolt, Berenek, and Newman packet switches.

No.

Element Combination

Series

Separator

1.

1

9

, SP

2.

1 SP 2 SP 3 SP 4 SP 5

9

; SP


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: S&E - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

O

P

P

Action Codes

I,E

I,E

O,D

O,D

I,O, C,T, D,E, R

I,O, C,T, D,E, R

C,T, R

-

-


CRIS

CABS

Data Retention

Yes

Yes

Printed on CSR

Yes

Yes




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.




iconectiv Confidential - Restricted Access

This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv.

Licensed Material - Property of iconectiv

Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv.