WRG |
WIRING |
INDICATES: |
New wiring, partial wiring, or no wiring involved in each station, equipment or station line installation, e.g., sets, jacks, auxiliary equipment, etc., in accordance with the local OTC tariff. This information is reported by the installer to the completions clerk and entered on the post-completion order. |
DATE: |
3/21/1991 |
BILLING: |
CRIS |
APPLICATIONS: |
General Purpose |
SECTION - POSITION |
EXAMPLES |
BILL - LH |
|
IWRG 3/CNP PG 1000 |
|
BILL - FL |
|
ICNP PG 1000/WRG 3 |
|
S&E - FL |
|
Single Condition Entry |
FID RULES/CONSTRAINTS: |
|
SECTION - POSITION |
APPEARANCE |
MODE |
MIN |
MAX |
BILL - LH |
Required |
Numeric |
1 |
4 |
Element: 1 |
Number of Wires Worked On |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Required |
Numeric |
1 |
4 |
No |
No |
Data Parameters: |
||
|
SECTION - POSITION |
|
BILL - FL |
Please refer to BILL - LH for all data requirements. |
SECTION - POSITION |
APPEARANCE |
MODE |
MIN |
MAX |
S&E - FL |
Required |
Alphanumeric |
1 |
5 |
Element: 1 |
Wiring Work Indicator |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Required |
Alphabetic |
1 |
1 |
No |
No |
Code Set: |
||||||||
|
Element: 2 |
Number of Wires Worked On |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
1 |
4 |
No |
No |
Data Parameters: |
||
|
No. |
Element Combination |
Series |
Separator |
1. |
1 |
Yes |
, SP |
2. |
1 2 |
Yes |
, SP |
ORDER TYPE/ACTION CODE/FID RELATIONSHIPS |
Order Section - Position: BILL - LH
|
Order Type |
N |
T |
F |
D |
C |
R |
X |
P |
A |
Presence |
O |
O |
P |
P |
O |
P |
O |
P |
P |
Action Codes |
I |
I |
- |
- |
I |
- |
I |
- |
- |
Other FIDs Required Logical Line |
CNP |
CNP |
- |
- |
CNP |
- |
CNP |
- |
- |
CRIS |
CABS |
|
Data Retention |
No |
No |
Printed on CSR |
No |
No |
Order Section - Position: BILL - FL
|
Please refer to BILL - LH for Order Type, Action Code, and FID relationships. |
Order Section - Position: S&E - FL
|
Order Type |
N |
T |
F |
D |
C |
R |
X |
P |
A |
Presence |
O |
O |
O |
O |
O |
O |
O |
O |
P |
Action Codes |
I,E |
I,E |
O,D |
O,D |
I,O C,T D,E X,R M |
I,O C,T D,E X,R M |
I,O C,T R |
I |
- |
CRIS |
CABS |
|
Data Retention |
No |
No |
Printed on CSR |
No |
No |
Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure. |
iconectiv Confidential - Restricted Access This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv. |
Licensed Material - Property of iconectiv Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv. |