WRO

WATS RECORDING OFFICE

INDICATES:

The switching machine that is providing Automatic Message Accounting (AMA) recording for 800 Service.

DATE:

10/31/2014

BILLING:

CRIS and CABS

APPLICATIONS:

800 Service, Access Service, Access Service Request (ASR)


SECTION - POSITION

EXAMPLES

S&E - FL

I1   @@A/SIT 800 555-1234/SIS 1    
     /STN 732 555-1234/SFG 13
     /WRO 201 332

            or

I1   @@A/SIT 800 555-1234/SIS 1 
     /STN 732 555-1234/SFG 13
     /WRO 201 PCR

FID RULES/CONSTRAINTS:

  1. T, F and X order types prohibited for Access Service Application.
  2. X action codes prohibited on Access Service Orders.
  3. WRO is used only if the Central Office Unit servicing the subscriber's 800 Service Access Line is not providing AMA recording.

REFERENCES:

  1. ATIS/OBF-ASR-009, WRO field

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - FL

Required

Alphanumeric

7

7

Element: 1

Numbering Plan Area Code

Appearance

Mode

Min

Max

Series

Range

Required

Numeric

3

3

No

No

Reference:

See iconectiv LERG Routing Guide for complete list.

Element: 2

Central Office Code

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

3

3

No

No

Reference:

See iconectiv LERG Routing Guide for complete list.

Element Rules:

Required when Toll Tandem Screening Office is not present; not allowed when Toll Tandem Screening Office is present.

Element: 3

Toll Tandem Screening Office

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

3

3

No

No

Code Set:

CodeMeaning
PCRPrincipal City Route

Element Rules:

Required when Central Office Code is not present; not allowed when Central Office Code is present.

No.

Element Combination

Series

Separator

1.

1 SP 2

No

2.

1 SP 3

No


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: S&E - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

O

P

P

Action Codes

I,E

I,E

O,D

O,D

I,O, C,T, D,E, M,X, R

I,O, C,T, D,E, M,X, R

I,O, C,T, R

-

-

Other FIDs Required Logical Line

STN, SFG

STN, SFG

STN, SFG

STN, SFG

STN, SFG

STN, SFG

STN, SFG

-

-

Other FIDs Prohibited Logical Line

RGN, RGR, CLN, CTR

RGN, RGR, CLN, CTR

RGN, RGR, CLN, CTR

RGN, RGR, CLN, CTR

RGN, RGR, CLN, CTR

RGN, RGR, CLN, CTR

RGN, RGR, CLN, CTR

-

-


CRIS

CABS

Data Retention

Yes

Yes

Printed on CSR

Yes

Yes




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.




iconectiv Confidential - Restricted Access

This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv.

Licensed Material - Property of iconectiv

Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv.