XLAT

CROSS LATA REASON

INDICATES:

The reason for approving a cross LATA service exemption when implementation of the service, which involves multiple central office exchanges that cross LATA boundaries, would normally not be permitted.

DATE:

3/20/2003

BILLING:

CRIS and CABS

APPLICATIONS:

Advanced Intelligent Network (AIN), Local Competition, Long Distance Competition


SECTION - POSITION

EXAMPLES

S&E - LH

IXLAT|911 AB1234

S&E - FL

I1    @@A/TN 732 555-1234
      /XLAT OCS CD5678

FID RULES/CONSTRAINTS:

  1. T, F, and X order types prohibited for Access Service application.
  2. X action code prohibited on Access Service orders.

SERVICE ORDER ACTIVITY NOTES:

  1. The XLAT FID identifies reasons for the provisioning of service across LATA boundaries.

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - LH

Required

Alphanumeric

10

10

Element: 1

Reason Code

Appearance

Mode

Min

Max

Series

Range

Required

Alphanumeric

3

3

No

No

Code Set:

CodeMeaning
911911 Services
AFFAffiliate
CLCCLEC
EASExtended Area of Service
JMKJoint Marketing
MFJModified Final Judgement
OCSOfficial Company Services
TRKTrunking
UNEUnbundled Network Elements
WHLWholesale

Element: 2

Approver's ID

Appearance

Mode

Min

Max

Series

Range

Required

Alphanumeric

6

6

No

No

Data Parameters:

A-Z
0-9

No.

Element Combination

Series

Separator

1.

1 SP 2

No


SECTION - POSITION

S&E - FL

Please refer to S&E - LH for all data requirements.


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: S&E - LH

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

O

P

P

Action Codes

I, E

I, E

O, D

O, D

I, O, C, T

I, O, C, T

I, O

-

-


CRIS

CABS

Data Retention

Yes

Yes

Printed on CSR

No

No

Order Section - Position: S&E - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

O

P

P

Action Codes

I, E

I, E

O, D

O, D

I, O, C, T, D, E, M, X, R

I, O, C, T, D, E, M, X, R

I, O, C, T, R

-

-


CRIS

CABS

Data Retention

Yes

Yes

Printed on CSR

No

No




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.




iconectiv Confidential - Restricted Access

This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv.

Licensed Material - Property of iconectiv

Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv.