YPAH

DORMITORY TELEPHONE SERVICE - PREVIOUS ACCOUNT HISTORY

INDICATES:

The month and year service was established for dormitory telephone service.

DATE:

10/31/2014

BILLING:

CRIS and CABS

APPLICATIONS:

Billing, Dormitory Service


SECTION - POSITION

EXAMPLES

S&E - FL

IYPAH|5-05 D MR

FID RULES/CONSTRAINTS:

  1. At the time of issuance, this FID was not supported by Telcordia and/or Ericsson Operations Support Systems (OSSs). Please check with your local OSS staff for processing capabilities (current and/or proposed) for the specific OSS.

SERVICE ORDER ACTIVITY NOTES:

  1. Due to local requirements, dormitory telephone service billing FIDs are contained in the S&E section of the service order.

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - FL

Required

Alphanumeric

4

12

Element: 1

Month - Numeric (Previous Service Established)

Appearance

Mode

Min

Max

Series

Range

Required

Numeric

1

2

No

No

Data Parameters:

1-12
01-12

Element: 2

Year of Century (Previous Service Established)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

2

2

No

No

Data Parameters:

00-99

Element: 3

Calendar Year (Previous Service Established)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

4

4

No

No

Data Parameters:

0000-9999

Element: 4

Suspension (Denial) for Non-Payment Indicator

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

1

1

No

No

Code Set:

CodeMeaning
DDenial

Element: 5

Manual Review Indicator

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

2

2

No

No

Code Set:

CodeMeaning
MRManual Review

No.

Element Combination

Series

Separator

1.

1 - 2

No

2.

1 - 2 SP 4

No

3.

1 - 2 SP 4 SP 5

No

4.

1 - 2 SP 5

No

5.

1 - 3

No

6.

1 - 3 SP 4

No

7.

1 - 3 SP 4 SP 5

No

8.

1 - 3 SP 5

No


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: S&E - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

P

P

P

O

O

P

P

P

Action Codes

I

-

-

-

I

I

-

-

-


CRIS

CABS

Data Retention

Yes

Yes

Printed on CSR

Yes

Yes




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.




iconectiv Confidential - Restricted Access

This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv.

Licensed Material - Property of iconectiv

Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv.